Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study

Introduction: Mini implants form a valuable source for absolute anchorage thereby helping in achieving ideal treatment outcome. Stability of the mini implant is one of the important factors affecting the success of mini implants. Thread shape is a critical factor in the engineering design of min...

Full description

Bibliographic Details
Main Authors: Aniruddh V. Yashwant, S. Dilip, R. Krishnaraj, K. Ravi
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2017-05-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/9808/25774_CE[Ra]_F(Sh)_PF1(P_SY)_PFA(SY_SS).pdf
id doaj-b8d74286926444df884aeefc186305d7
record_format Article
spelling doaj-b8d74286926444df884aeefc186305d72020-11-25T03:46:42ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2017-05-01115ZC17ZC2010.7860/JCDR/2017/25774.9808Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro StudyAniruddh V. Yashwant0S. Dilip1R. Krishnaraj2K. Ravi3Senior Lecturer, Department of Orthodontics and Dentofacial Orthopaedics, Indira Gandhi Institute of Dental Sciences, Mahatma Gandhi Medical College Campus, Sri Balaji Vidyapeeth University, Pillaiyarkuppam, Puducherry, India.Professor, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, India.Professor, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, India.Professor and Head, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, India.Introduction: Mini implants form a valuable source for absolute anchorage thereby helping in achieving ideal treatment outcome. Stability of the mini implant is one of the important factors affecting the success of mini implants. Thread shape is a critical factor in the engineering design of mini implant, which affects the primary stability. Aim: To evaluate the effects of thread shape on the pull out strength of mini implants. Materials and Methods: Mini implants of five different designs in thread shape (reverse buttress, buttress, 750 joint profile with flutes, trapezoidal and trapezoidal fluted) were used with 10 screws in each group. The mini implants were loaded on to the polyurethane foam block (Sawbones pacific research lab, USA) perpendicular to the surface and the pull out strength was tested using the Instrom testing machine. The control group consisted of mini implants with reverse buttress thread shape. One-way ANOVA and Tukey post-hoc tests were used to compare the pull out strength of the mini implants within as well as between the different groups. Results: The mean in the pull out tests ranged from 13.45 N (trapezoidal) to 61 N (trapezoidal fluted). The tukey post-hoc tests showed a statistically significant difference of 34.5 N between the control group and the trapezoidal fluted group. The level of statistical significance showed p< 0.05. Conclusion: Trapezoidal fluted mini implants showed the highest pull out strength when compared to mini implants with other thread designs used in this study. Further studies with the use of Finite Element Method (FEM) and foam blocks of higher density would be required to evaluate the performance of this new thread design.https://jcdr.net/articles/PDF/9808/25774_CE[Ra]_F(Sh)_PF1(P_SY)_PFA(SY_SS).pdfanchoragestabilitytrapezoidal fluted
collection DOAJ
language English
format Article
sources DOAJ
author Aniruddh V. Yashwant
S. Dilip
R. Krishnaraj
K. Ravi
spellingShingle Aniruddh V. Yashwant
S. Dilip
R. Krishnaraj
K. Ravi
Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study
Journal of Clinical and Diagnostic Research
anchorage
stability
trapezoidal fluted
author_facet Aniruddh V. Yashwant
S. Dilip
R. Krishnaraj
K. Ravi
author_sort Aniruddh V. Yashwant
title Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study
title_short Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study
title_full Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study
title_fullStr Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study
title_full_unstemmed Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study
title_sort does change in thread shape influence the pull out strength of mini implants? an in vitro study
publisher JCDR Research and Publications Private Limited
series Journal of Clinical and Diagnostic Research
issn 2249-782X
0973-709X
publishDate 2017-05-01
description Introduction: Mini implants form a valuable source for absolute anchorage thereby helping in achieving ideal treatment outcome. Stability of the mini implant is one of the important factors affecting the success of mini implants. Thread shape is a critical factor in the engineering design of mini implant, which affects the primary stability. Aim: To evaluate the effects of thread shape on the pull out strength of mini implants. Materials and Methods: Mini implants of five different designs in thread shape (reverse buttress, buttress, 750 joint profile with flutes, trapezoidal and trapezoidal fluted) were used with 10 screws in each group. The mini implants were loaded on to the polyurethane foam block (Sawbones pacific research lab, USA) perpendicular to the surface and the pull out strength was tested using the Instrom testing machine. The control group consisted of mini implants with reverse buttress thread shape. One-way ANOVA and Tukey post-hoc tests were used to compare the pull out strength of the mini implants within as well as between the different groups. Results: The mean in the pull out tests ranged from 13.45 N (trapezoidal) to 61 N (trapezoidal fluted). The tukey post-hoc tests showed a statistically significant difference of 34.5 N between the control group and the trapezoidal fluted group. The level of statistical significance showed p< 0.05. Conclusion: Trapezoidal fluted mini implants showed the highest pull out strength when compared to mini implants with other thread designs used in this study. Further studies with the use of Finite Element Method (FEM) and foam blocks of higher density would be required to evaluate the performance of this new thread design.
topic anchorage
stability
trapezoidal fluted
url https://jcdr.net/articles/PDF/9808/25774_CE[Ra]_F(Sh)_PF1(P_SY)_PFA(SY_SS).pdf
work_keys_str_mv AT aniruddhvyashwant doeschangeinthreadshapeinfluencethepulloutstrengthofminiimplantsaninvitrostudy
AT sdilip doeschangeinthreadshapeinfluencethepulloutstrengthofminiimplantsaninvitrostudy
AT rkrishnaraj doeschangeinthreadshapeinfluencethepulloutstrengthofminiimplantsaninvitrostudy
AT kravi doeschangeinthreadshapeinfluencethepulloutstrengthofminiimplantsaninvitrostudy
_version_ 1724504774946062336