An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective asses...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-05-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/10/10/3436 |
id |
doaj-b86f5d0128f049689b1d09d320681c78 |
---|---|
record_format |
Article |
spelling |
doaj-b86f5d0128f049689b1d09d320681c782020-11-25T03:12:31ZengMDPI AGApplied Sciences2076-34172020-05-01103436343610.3390/app10103436An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility StudyAbdallah Alsayed0Raja Kamil1Hafiz Ramli2Azizan As'arry3Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaDepartment of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaDepartment of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaDepartment of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaThe Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective assessment. In this study, an automated data acquisition system that consists of a linear electric actuator applying automatic pulling to the customized pincer object held by the volunteer was developed. The pinch force was measured such that a strain gauge was placed on the pincer object while pulling force was measured using pulling force load cell connected in between the linear electric actuator and customized pincer object. The pincer object’s slip onset was detected using a displacement slip sensor. The mean pinch and pulling force values at the slip onset were 12.17 and 6.25 N for right hands, while mean pinch and pulling force values were 11.67 and 5.92 N for left hands of 50 healthy volunteers, respectively. Based on the paired <i>t</i>-test, there is no significant difference between right and left hands. The automated data acquisition system can objectively apply a pulling force, detect the slip onset, and measure the pinch and pulling forces.https://www.mdpi.com/2076-3417/10/10/3436Automated assessmentUE-FMAPinch forcePulling forceSlip onsetStrain gauge |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Abdallah Alsayed Raja Kamil Hafiz Ramli Azizan As'arry |
spellingShingle |
Abdallah Alsayed Raja Kamil Hafiz Ramli Azizan As'arry An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study Applied Sciences Automated assessment UE-FMA Pinch force Pulling force Slip onset Strain gauge |
author_facet |
Abdallah Alsayed Raja Kamil Hafiz Ramli Azizan As'arry |
author_sort |
Abdallah Alsayed |
title |
An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study |
title_short |
An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study |
title_full |
An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study |
title_fullStr |
An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study |
title_full_unstemmed |
An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study |
title_sort |
automated data acquisition system for pinch grip assessment based on fugl meyer protocol: a feasibility study |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2020-05-01 |
description |
The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective assessment. In this study, an automated data acquisition system that consists of a linear electric actuator applying automatic pulling to the customized pincer object held by the volunteer was developed. The pinch force was measured such that a strain gauge was placed on the pincer object while pulling force was measured using pulling force load cell connected in between the linear electric actuator and customized pincer object. The pincer object’s slip onset was detected using a displacement slip sensor. The mean pinch and pulling force values at the slip onset were 12.17 and 6.25 N for right hands, while mean pinch and pulling force values were 11.67 and 5.92 N for left hands of 50 healthy volunteers, respectively. Based on the paired <i>t</i>-test, there is no significant difference between right and left hands. The automated data acquisition system can objectively apply a pulling force, detect the slip onset, and measure the pinch and pulling forces. |
topic |
Automated assessment UE-FMA Pinch force Pulling force Slip onset Strain gauge |
url |
https://www.mdpi.com/2076-3417/10/10/3436 |
work_keys_str_mv |
AT abdallahalsayed anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT rajakamil anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT hafizramli anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT azizanasarry anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT abdallahalsayed automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT rajakamil automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT hafizramli automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy AT azizanasarry automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy |
_version_ |
1724650053009670144 |