An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study

The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective asses...

Full description

Bibliographic Details
Main Authors: Abdallah Alsayed, Raja Kamil, Hafiz Ramli, Azizan As'arry
Format: Article
Language:English
Published: MDPI AG 2020-05-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/10/10/3436
id doaj-b86f5d0128f049689b1d09d320681c78
record_format Article
spelling doaj-b86f5d0128f049689b1d09d320681c782020-11-25T03:12:31ZengMDPI AGApplied Sciences2076-34172020-05-01103436343610.3390/app10103436An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility StudyAbdallah Alsayed0Raja Kamil1Hafiz Ramli2Azizan As'arry3Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaDepartment of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaDepartment of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaDepartment of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, MalaysiaThe Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective assessment. In this study, an automated data acquisition system that consists of a linear electric actuator applying automatic pulling to the customized pincer object held by the volunteer was developed. The pinch force was measured such that a strain gauge was placed on the pincer object while pulling force was measured using pulling force load cell connected in between the linear electric actuator and customized pincer object. The pincer object’s slip onset was detected using a displacement slip sensor. The mean pinch and pulling force values at the slip onset were 12.17 and 6.25 N for right hands, while mean pinch and pulling force values were 11.67 and 5.92 N for left hands of 50 healthy volunteers, respectively. Based on the paired <i>t</i>-test, there is no significant difference between right and left hands. The automated data acquisition system can objectively apply a pulling force, detect the slip onset, and measure the pinch and pulling forces.https://www.mdpi.com/2076-3417/10/10/3436Automated assessmentUE-FMAPinch forcePulling forceSlip onsetStrain gauge
collection DOAJ
language English
format Article
sources DOAJ
author Abdallah Alsayed
Raja Kamil
Hafiz Ramli
Azizan As'arry
spellingShingle Abdallah Alsayed
Raja Kamil
Hafiz Ramli
Azizan As'arry
An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
Applied Sciences
Automated assessment
UE-FMA
Pinch force
Pulling force
Slip onset
Strain gauge
author_facet Abdallah Alsayed
Raja Kamil
Hafiz Ramli
Azizan As'arry
author_sort Abdallah Alsayed
title An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
title_short An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
title_full An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
title_fullStr An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
title_full_unstemmed An Automated Data Acquisition System for Pinch Grip Assessment Based on Fugl Meyer Protocol: A Feasibility Study
title_sort automated data acquisition system for pinch grip assessment based on fugl meyer protocol: a feasibility study
publisher MDPI AG
series Applied Sciences
issn 2076-3417
publishDate 2020-05-01
description The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective assessment. In this study, an automated data acquisition system that consists of a linear electric actuator applying automatic pulling to the customized pincer object held by the volunteer was developed. The pinch force was measured such that a strain gauge was placed on the pincer object while pulling force was measured using pulling force load cell connected in between the linear electric actuator and customized pincer object. The pincer object’s slip onset was detected using a displacement slip sensor. The mean pinch and pulling force values at the slip onset were 12.17 and 6.25 N for right hands, while mean pinch and pulling force values were 11.67 and 5.92 N for left hands of 50 healthy volunteers, respectively. Based on the paired <i>t</i>-test, there is no significant difference between right and left hands. The automated data acquisition system can objectively apply a pulling force, detect the slip onset, and measure the pinch and pulling forces.
topic Automated assessment
UE-FMA
Pinch force
Pulling force
Slip onset
Strain gauge
url https://www.mdpi.com/2076-3417/10/10/3436
work_keys_str_mv AT abdallahalsayed anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT rajakamil anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT hafizramli anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT azizanasarry anautomateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT abdallahalsayed automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT rajakamil automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT hafizramli automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
AT azizanasarry automateddataacquisitionsystemforpinchgripassessmentbasedonfuglmeyerprotocolafeasibilitystudy
_version_ 1724650053009670144