Hydroxyethyl starch versus Ringer solution in cardiopulmonary bypass prime solutions (a randomized controlled trial)

<p>Abstract</p> <p>Background</p> <p>In our study we compared the Ringer solution, which is the standard prime solution of our department, with the HES (Hydroxyethyl starch) 130-0.4 solution, which can be a potential alternative prime solution with an indispensable mate...

Full description

Bibliographic Details
Main Authors: Ozyazıcıoglu Ahmet, Goncu Tugrul, Vural Hakan, Yıldız Gürdeniz, Tiryakioğlu Osman, Yavuz Şenol
Format: Article
Language:English
Published: BMC 2008-07-01
Series:Journal of Cardiothoracic Surgery
Online Access:http://www.cardiothoracicsurgery.org/content/3/1/45
Description
Summary:<p>Abstract</p> <p>Background</p> <p>In our study we compared the Ringer solution, which is the standard prime solution of our department, with the HES (Hydroxyethyl starch) 130-0.4 solution, which can be a potential alternative prime solution with an indispensable material for the cardio-pulmonary bypass applications.</p> <p>Methods</p> <p>140 patients undergoing to CABG (Coronary Artery Bypass Graft surgery) were electively enrolled to the study. 1500 ml Ringer solution + 200 ml mannitol + 60 ml sodium bicarbonate + 150 U/kg heparin was used as a prime solution to start cardiopulmonary by-pass in 70 patients which was defined as group 1. On the other hand, 1500 ml HES 130 - 0.4 + 200 ml mannitol + 60 ml sodium bicarbonate + 150 U/kg heparin was used as a prime solution in 70 patients in group 2.</p> <p>Results</p> <p>INR (International Normalized Ratio), urea levels and blood platelet counts were significantly different between the groups. INR level was higher in group 1, while blood urea and creatinine levels and platelet count were higher in group 2 at the end of the 12th and 24nd hours postoperatively (p = 0.001).</p> <p>In this study, it was shown that the usage of HES 130-0.4 as a prime solution did not have negative effect on postoperative INR level, platelet count, the need for transfusion and the amount of drainage, despite the negative opinions that similar solutions caused coagulation disorders. Another interesting result of the study was that blood platelet count at 24th hour was statistically significantly higher in group 2 (p = 0.001).</p> <p>Conclusion</p> <p>HES 130-0.4 solution is an alternative colloidal solution which can be used as the prime solution or as a mixture with the crystalloids in cardio-pulmonary bypass applications.</p>
ISSN:1749-8090