Use of dried blood samples for monitoring hepatitis B virus infection

<p>Abstract</p> <p>Background</p> <p>Hepatitis B virus (HBV) infection is a problem in several regions of the world with limited resources. Blood samples dried on filter paper (DBS) have been successfully used to diagnose and monitor several infectious diseases. In Mexi...

Full description

Bibliographic Details
Main Authors: Muñoz Onofre, Gomez-Delgado Alejandro, Cano-Dominguez Carlos, Valdez-Salazar Hilda, Torres-Ibarra Rocio, Ruiz-Tachiquin Martha, Rojas-Montes Othon, Maldonado-Rodriguez Angelica, Lira Rosalia, Alvarez-Muñoz Ma-Teresa
Format: Article
Language:English
Published: BMC 2009-09-01
Series:Virology Journal
Online Access:http://www.virologyj.com/content/6/1/153
id doaj-b7c4318f9acc42baa4c2da65ac410022
record_format Article
spelling doaj-b7c4318f9acc42baa4c2da65ac4100222020-11-24T23:58:14ZengBMCVirology Journal1743-422X2009-09-016115310.1186/1743-422X-6-153Use of dried blood samples for monitoring hepatitis B virus infectionMuñoz OnofreGomez-Delgado AlejandroCano-Dominguez CarlosValdez-Salazar HildaTorres-Ibarra RocioRuiz-Tachiquin MarthaRojas-Montes OthonMaldonado-Rodriguez AngelicaLira RosaliaAlvarez-Muñoz Ma-Teresa<p>Abstract</p> <p>Background</p> <p>Hepatitis B virus (HBV) infection is a problem in several regions of the world with limited resources. Blood samples dried on filter paper (DBS) have been successfully used to diagnose and monitor several infectious diseases. In Mexico there is an urgent need for an affordable and easy sampling method for viral load (VL) testing and monitoring of chronic HBV infection. The purpose of this work was to validate the utility of DBS samples for monitoring HBV infection in patients from Mexico City.</p> <p>Methods</p> <p>Matched samples of plasma and DBS on filter paper from 47 HBV infected patients from the Instituto Mexicano del Seguro Social (IMSS), were included. To evaluate the DNA stability and purity from DBS stored at different temperature conditions, samples from ten patients were stored at 4 degree, 25 degree, and 37 degree C for 7 days. After DBS elution and DNA extraction, the purity of these samples was determined measuring the O.D. rate 260/280. The DBS utility for molecular studies was assessed with PCR assays to amplify a 322 bp fragment from the "a" determinant region of the HBV "S" gene. The VL from all samples was determined to evaluate the correlation between plasma and DBS matched samples.</p> <p>Results</p> <p>The quality of the DNA from DBS specimen is not adversely affected by storage at 4 degree, 25 degree and 37 degree C for up 7 days. Statistical ANOVA analyses did not show any significant difference. The same amplification efficiency was observed between DNA templates from samples stored at different temperatures. The Pearson correlation between the VL from DBS and plasma matched samples was 0.93 (p = 0.01). The SD was 1.48 for DBS vs.1.32 for Plasma, and an average of log<sub>10 </sub>copies/mL of 5.32 vs. 5.53. ANOVA analysis did not show any statistically significant difference between the analyzed groups (p = 0.92).</p> <p>Conclusion</p> <p>The results provide strong evidence that the isolation and quantification of DNA-HBV from DBS is a viable alternative for patient monitoring, and molecular characterization of the virus variants circulating in Mexico.</p> http://www.virologyj.com/content/6/1/153
collection DOAJ
language English
format Article
sources DOAJ
author Muñoz Onofre
Gomez-Delgado Alejandro
Cano-Dominguez Carlos
Valdez-Salazar Hilda
Torres-Ibarra Rocio
Ruiz-Tachiquin Martha
Rojas-Montes Othon
Maldonado-Rodriguez Angelica
Lira Rosalia
Alvarez-Muñoz Ma-Teresa
spellingShingle Muñoz Onofre
Gomez-Delgado Alejandro
Cano-Dominguez Carlos
Valdez-Salazar Hilda
Torres-Ibarra Rocio
Ruiz-Tachiquin Martha
Rojas-Montes Othon
Maldonado-Rodriguez Angelica
Lira Rosalia
Alvarez-Muñoz Ma-Teresa
Use of dried blood samples for monitoring hepatitis B virus infection
Virology Journal
author_facet Muñoz Onofre
Gomez-Delgado Alejandro
Cano-Dominguez Carlos
Valdez-Salazar Hilda
Torres-Ibarra Rocio
Ruiz-Tachiquin Martha
Rojas-Montes Othon
Maldonado-Rodriguez Angelica
Lira Rosalia
Alvarez-Muñoz Ma-Teresa
author_sort Muñoz Onofre
title Use of dried blood samples for monitoring hepatitis B virus infection
title_short Use of dried blood samples for monitoring hepatitis B virus infection
title_full Use of dried blood samples for monitoring hepatitis B virus infection
title_fullStr Use of dried blood samples for monitoring hepatitis B virus infection
title_full_unstemmed Use of dried blood samples for monitoring hepatitis B virus infection
title_sort use of dried blood samples for monitoring hepatitis b virus infection
publisher BMC
series Virology Journal
issn 1743-422X
publishDate 2009-09-01
description <p>Abstract</p> <p>Background</p> <p>Hepatitis B virus (HBV) infection is a problem in several regions of the world with limited resources. Blood samples dried on filter paper (DBS) have been successfully used to diagnose and monitor several infectious diseases. In Mexico there is an urgent need for an affordable and easy sampling method for viral load (VL) testing and monitoring of chronic HBV infection. The purpose of this work was to validate the utility of DBS samples for monitoring HBV infection in patients from Mexico City.</p> <p>Methods</p> <p>Matched samples of plasma and DBS on filter paper from 47 HBV infected patients from the Instituto Mexicano del Seguro Social (IMSS), were included. To evaluate the DNA stability and purity from DBS stored at different temperature conditions, samples from ten patients were stored at 4 degree, 25 degree, and 37 degree C for 7 days. After DBS elution and DNA extraction, the purity of these samples was determined measuring the O.D. rate 260/280. The DBS utility for molecular studies was assessed with PCR assays to amplify a 322 bp fragment from the "a" determinant region of the HBV "S" gene. The VL from all samples was determined to evaluate the correlation between plasma and DBS matched samples.</p> <p>Results</p> <p>The quality of the DNA from DBS specimen is not adversely affected by storage at 4 degree, 25 degree and 37 degree C for up 7 days. Statistical ANOVA analyses did not show any significant difference. The same amplification efficiency was observed between DNA templates from samples stored at different temperatures. The Pearson correlation between the VL from DBS and plasma matched samples was 0.93 (p = 0.01). The SD was 1.48 for DBS vs.1.32 for Plasma, and an average of log<sub>10 </sub>copies/mL of 5.32 vs. 5.53. ANOVA analysis did not show any statistically significant difference between the analyzed groups (p = 0.92).</p> <p>Conclusion</p> <p>The results provide strong evidence that the isolation and quantification of DNA-HBV from DBS is a viable alternative for patient monitoring, and molecular characterization of the virus variants circulating in Mexico.</p>
url http://www.virologyj.com/content/6/1/153
work_keys_str_mv AT munozonofre useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT gomezdelgadoalejandro useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT canodominguezcarlos useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT valdezsalazarhilda useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT torresibarrarocio useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT ruiztachiquinmartha useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT rojasmontesothon useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT maldonadorodriguezangelica useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT lirarosalia useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
AT alvarezmunozmateresa useofdriedbloodsamplesformonitoringhepatitisbvirusinfection
_version_ 1725450959500345344