Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials

OBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Truso...

Full description

Bibliographic Details
Main Authors: Ana Lucia Machado, Eunice Teresinha Giampaolo, Carlos Eduardo Vergani, Juliana Feltrin de Souza, Janaina Habib Jorge
Format: Article
Language:English
Published: University of São Paulo 2011-10-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000500015
id doaj-b7a87faed2374390a9bb776b59a214c8
record_format Article
spelling doaj-b7a87faed2374390a9bb776b59a214c82020-11-24T22:58:33ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652011-10-0119552152810.1590/S1678-77572011000500015Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materialsAna Lucia MachadoEunice Teresinha GiampaoloCarlos Eduardo VerganiJuliana Feltrin de SouzaJanaina Habib JorgeOBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS: Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05). RESULTS: At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P<0.041) and New Truliner (0.19 to 0.76 µm; P<0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05). CONCLUSIONS: The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000500015Surface propertiesDenture rebasingDenture basesMicrowavesChemical compounds
collection DOAJ
language English
format Article
sources DOAJ
author Ana Lucia Machado
Eunice Teresinha Giampaolo
Carlos Eduardo Vergani
Juliana Feltrin de Souza
Janaina Habib Jorge
spellingShingle Ana Lucia Machado
Eunice Teresinha Giampaolo
Carlos Eduardo Vergani
Juliana Feltrin de Souza
Janaina Habib Jorge
Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
Journal of Applied Oral Science
Surface properties
Denture rebasing
Denture bases
Microwaves
Chemical compounds
author_facet Ana Lucia Machado
Eunice Teresinha Giampaolo
Carlos Eduardo Vergani
Juliana Feltrin de Souza
Janaina Habib Jorge
author_sort Ana Lucia Machado
title Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
title_short Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
title_full Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
title_fullStr Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
title_full_unstemmed Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials
title_sort changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials
publisher University of São Paulo
series Journal of Applied Oral Science
issn 1678-7757
1678-7765
publishDate 2011-10-01
description OBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS: Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05). RESULTS: At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P<0.041) and New Truliner (0.19 to 0.76 µm; P<0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05). CONCLUSIONS: The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft.
topic Surface properties
Denture rebasing
Denture bases
Microwaves
Chemical compounds
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000500015
work_keys_str_mv AT analuciamachado changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT euniceteresinhagiampaolo changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT carloseduardovergani changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT julianafeltrindesouza changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT janainahabibjorge changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
_version_ 1725646882301018112