Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller

The power system must be able to server the load in a sustainable manner with good service quality, such as constant voltage and frequency, quickly stabilized when load changes occur. The control generator automatically changes the frequency to the highest value when the system changes every time. T...

Full description

Bibliographic Details
Main Authors: Made Dwi Noviantara, I Nengah Suweden, I Made Mataram
Format: Article
Language:English
Published: Universitas Udayana 2018-09-01
Series:Majalah Ilmiah Teknologi Elektro
Online Access:https://ojs.unud.ac.id/index.php/JTE/article/view/37360
id doaj-b71aa961cee248c099516efce8a7c47a
record_format Article
spelling doaj-b71aa961cee248c099516efce8a7c47a2020-11-25T02:51:57ZengUniversitas UdayanaMajalah Ilmiah Teknologi Elektro1693-29512503-23722018-09-0117226327010.24843/MITE.2018.v17i02.P1537360Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic ControllerMade Dwi Noviantara0I Nengah SuwedenI Made MataramUniversitas UdayanaThe power system must be able to server the load in a sustainable manner with good service quality, such as constant voltage and frequency, quickly stabilized when load changes occur. The control generator automatically changes the frequency to the highest value when the system changes every time. This is called AGC. To keep the frequency in a stable state required frequency control system. Currently developing a lot of control system with fuzzy logic method. The simulation is performed using 5 membership functions and gives a loading of 0.1 pu, using MATLAB-Simulink software. From the analysis result, the comparison of output of frequency response in overshoot condition with conventional method yielded , settling time of 20.5 second. While the fuzzy logic controller method produces frequency response output in the overshoot state that is , settling time is 12 seconds. Whit the fuzzy logic controller method produces better performance and faster than conventional methods.https://ojs.unud.ac.id/index.php/JTE/article/view/37360
collection DOAJ
language English
format Article
sources DOAJ
author Made Dwi Noviantara
I Nengah Suweden
I Made Mataram
spellingShingle Made Dwi Noviantara
I Nengah Suweden
I Made Mataram
Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller
Majalah Ilmiah Teknologi Elektro
author_facet Made Dwi Noviantara
I Nengah Suweden
I Made Mataram
author_sort Made Dwi Noviantara
title Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller
title_short Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller
title_full Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller
title_fullStr Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller
title_full_unstemmed Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller
title_sort analisis stabilitas sistem tenaga listrik dengan automatic generation control (agc) dua area menggunakan fuzzy logic controller
publisher Universitas Udayana
series Majalah Ilmiah Teknologi Elektro
issn 1693-2951
2503-2372
publishDate 2018-09-01
description The power system must be able to server the load in a sustainable manner with good service quality, such as constant voltage and frequency, quickly stabilized when load changes occur. The control generator automatically changes the frequency to the highest value when the system changes every time. This is called AGC. To keep the frequency in a stable state required frequency control system. Currently developing a lot of control system with fuzzy logic method. The simulation is performed using 5 membership functions and gives a loading of 0.1 pu, using MATLAB-Simulink software. From the analysis result, the comparison of output of frequency response in overshoot condition with conventional method yielded , settling time of 20.5 second. While the fuzzy logic controller method produces frequency response output in the overshoot state that is , settling time is 12 seconds. Whit the fuzzy logic controller method produces better performance and faster than conventional methods.
url https://ojs.unud.ac.id/index.php/JTE/article/view/37360
work_keys_str_mv AT madedwinoviantara analisisstabilitassistemtenagalistrikdenganautomaticgenerationcontrolagcduaareamenggunakanfuzzylogiccontroller
AT inengahsuweden analisisstabilitassistemtenagalistrikdenganautomaticgenerationcontrolagcduaareamenggunakanfuzzylogiccontroller
AT imademataram analisisstabilitassistemtenagalistrikdenganautomaticgenerationcontrolagcduaareamenggunakanfuzzylogiccontroller
_version_ 1724732387830530048