Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging

The relatively low success rates of current colorectal cancer (CRC) therapies have led investigators to search for more specific treatments. Vertebrate models of colorectal cancer are essential tools for the verification of new therapeutic avenues such as gene therapy. The evaluation of colorectal c...

Full description

Bibliographic Details
Main Authors: Jessica L Freeling, Khosrow Rezvani
Format: Article
Language:English
Published: Elsevier 2016-01-01
Series:Molecular Therapy: Methods & Clinical Development
Online Access:http://www.sciencedirect.com/science/article/pii/S2329050116301978
id doaj-b6c7d48d3997470597f771022f7d4b2d
record_format Article
spelling doaj-b6c7d48d3997470597f771022f7d4b2d2020-11-25T01:08:30ZengElsevierMolecular Therapy: Methods & Clinical Development2329-05012016-01-013C10.1038/mtm.2016.70Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imagingJessica L Freeling0Khosrow Rezvani1Division of Basic Biomedical Sciences, Sanford School of Medicine, The University of South Dakota, Vermillion, South Dakota, USADivision of Basic Biomedical Sciences, Sanford School of Medicine, The University of South Dakota, Vermillion, South Dakota, USAThe relatively low success rates of current colorectal cancer (CRC) therapies have led investigators to search for more specific treatments. Vertebrate models of colorectal cancer are essential tools for the verification of new therapeutic avenues such as gene therapy. The evaluation of colorectal cancer in mouse models has been limited due to the lack of an accurate quantitative and longitudinal noninvasive method. This work introduces a method of three-dimensional micro-ultrasound reconstruction and microbubble administration for the comprehensive and longitudinal evaluation of CRC progression. This approach enabled quantification of both tumor volume and relative vascularity using a well-established inducible murine model of colon carcinogenesis. This inducible model recapitulated the adenocarcinoma sequence that occurs in human CRC allowing systematic in situ evaluation of the ultrasound technique. The administration of intravenous microbubbles facilitated enhancement of colon vascular contrast and quantification of relative vascularity of the mid and distal colon of the mouse in three dimensions. In addition, two-dimensional imaging in the sagittal orientation of the colon using Non-Linear Contrast Mode enabled calculation of relative blood volume and perfusion as the microbubbles entered the colon microvasculature. Quantitative results provided by the outlined protocol represent a noninvasive tool that can more accurately define CRC development and progression. This ultrasound technique will allow the practical and economical longitudinal study of murine CRC in both basic and preclinical studies.http://www.sciencedirect.com/science/article/pii/S2329050116301978
collection DOAJ
language English
format Article
sources DOAJ
author Jessica L Freeling
Khosrow Rezvani
spellingShingle Jessica L Freeling
Khosrow Rezvani
Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
Molecular Therapy: Methods & Clinical Development
author_facet Jessica L Freeling
Khosrow Rezvani
author_sort Jessica L Freeling
title Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
title_short Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
title_full Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
title_fullStr Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
title_full_unstemmed Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
title_sort assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
publisher Elsevier
series Molecular Therapy: Methods & Clinical Development
issn 2329-0501
publishDate 2016-01-01
description The relatively low success rates of current colorectal cancer (CRC) therapies have led investigators to search for more specific treatments. Vertebrate models of colorectal cancer are essential tools for the verification of new therapeutic avenues such as gene therapy. The evaluation of colorectal cancer in mouse models has been limited due to the lack of an accurate quantitative and longitudinal noninvasive method. This work introduces a method of three-dimensional micro-ultrasound reconstruction and microbubble administration for the comprehensive and longitudinal evaluation of CRC progression. This approach enabled quantification of both tumor volume and relative vascularity using a well-established inducible murine model of colon carcinogenesis. This inducible model recapitulated the adenocarcinoma sequence that occurs in human CRC allowing systematic in situ evaluation of the ultrasound technique. The administration of intravenous microbubbles facilitated enhancement of colon vascular contrast and quantification of relative vascularity of the mid and distal colon of the mouse in three dimensions. In addition, two-dimensional imaging in the sagittal orientation of the colon using Non-Linear Contrast Mode enabled calculation of relative blood volume and perfusion as the microbubbles entered the colon microvasculature. Quantitative results provided by the outlined protocol represent a noninvasive tool that can more accurately define CRC development and progression. This ultrasound technique will allow the practical and economical longitudinal study of murine CRC in both basic and preclinical studies.
url http://www.sciencedirect.com/science/article/pii/S2329050116301978
work_keys_str_mv AT jessicalfreeling assessmentofmurinecolorectalcancerbymicroultrasoundusingthreedimensionalreconstructionandnonlinearcontrastimaging
AT khosrowrezvani assessmentofmurinecolorectalcancerbymicroultrasoundusingthreedimensionalreconstructionandnonlinearcontrastimaging
_version_ 1725182261503983616