Effect of weld heat input on corrosion of dissimilar welded pipeline steels under simulated coating disbondment protected by cathodic protection

Dissimilar welding is extensively used for oil and gas pipelines for new installations or repairs. Despite applying cathodic protection (CP) and coatings, corrosion and cracking can occur, usually on external surface of pipelines under coating disbondments close to weld lines. In this study, corrosi...

Full description

Bibliographic Details
Main Authors: R. Ashari, A. Eslami, M. Shamanian, S. Asghari
Format: Article
Language:English
Published: Elsevier 2020-03-01
Series:Journal of Materials Research and Technology