Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector
In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and s...
Main Author: | |
---|---|
Format: | Article |
Language: | Arabic |
Published: |
College of Science for Women, University of Baghdad
2012-12-01
|
Series: | Baghdad Science Journal |
Subjects: | |
Online Access: | http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/1421 |
id |
doaj-b6749f5b01ce45a98d38e362d8ccc866 |
---|---|
record_format |
Article |
spelling |
doaj-b6749f5b01ce45a98d38e362d8ccc8662020-11-25T00:36:58ZaraCollege of Science for Women, University of BaghdadBaghdad Science Journal2078-86652411-79862012-12-019410.21123/bsj.9.4.741-745Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 DetectorBaghdad Science Journal In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/1421' radon, LR-115, track detector, inhalation, radiation, alpha particles " |
collection |
DOAJ |
language |
Arabic |
format |
Article |
sources |
DOAJ |
author |
Baghdad Science Journal |
spellingShingle |
Baghdad Science Journal Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector Baghdad Science Journal ' radon, LR-115, track detector, inhalation, radiation, alpha particles " |
author_facet |
Baghdad Science Journal |
author_sort |
Baghdad Science Journal |
title |
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector |
title_short |
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector |
title_full |
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector |
title_fullStr |
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector |
title_full_unstemmed |
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector |
title_sort |
determination the concentration of the radon in some drinking bottled water in baghdad using lr-115 detector |
publisher |
College of Science for Women, University of Baghdad |
series |
Baghdad Science Journal |
issn |
2078-8665 2411-7986 |
publishDate |
2012-12-01 |
description |
In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon
|
topic |
' radon, LR-115, track detector, inhalation, radiation, alpha particles " |
url |
http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/1421 |
work_keys_str_mv |
AT baghdadsciencejournal determinationtheconcentrationoftheradoninsomedrinkingbottledwaterinbaghdadusinglr115detector |
_version_ |
1725303267300212736 |