Frequency Domain Diagnostics of Transformer Insulation

The first part of paper deals with the base information about diagnostics of power transformers. In this part are presented differently insulating methods, for example method of recovery voltage method, method of polarization and depolarization currents and chromatographic analysis.The second part o...

Full description

Bibliographic Details
Main Authors: M. Gutten, M. Šebok, D. Korenčiak, P. Brnčal, M. Kubiš, P. Żukowski, T. N. Koltunowicz
Format: Article
Language:English
Published: Belarusian National Technical University 2019-12-01
Series:Pribory i Metody Izmerenij
Subjects:
oil
Online Access:https://pimi.bntu.by/jour/article/view/558
id doaj-b672bc5de704446fb1a9313190f33ab6
record_format Article
spelling doaj-b672bc5de704446fb1a9313190f33ab62021-07-29T08:39:11ZengBelarusian National Technical UniversityPribory i Metody Izmerenij2220-95062414-04732019-12-0110435335910.21122/2220-9506-2019-10-4-353-359428Frequency Domain Diagnostics of Transformer InsulationM. Gutten0M. Šebok1D. Korenčiak2P. Brnčal3M. Kubiš4P. Żukowski5T. N. Koltunowicz6University of ŽilinaUniversity of ŽilinaUniversity of ŽilinaUniversity of ŽilinaUniversity of ŽilinaLublin University of TechnologyLublin University of TechnologyThe first part of paper deals with the base information about diagnostics of power transformers. In this part are presented differently insulating methods, for example method of recovery voltage method, method of polarization and depolarization currents and chromatographic analysis.The second part of paper deals use of method of frequency domain spectroscopy for oil power transformers. This method is used in analysis insulating condition of power transformer with system of oil-paper. It was found, that the results of these tests are highly impacted by the operating temperature during the experimental measurement. Moisture and conductivity between insulating paper and oil in an insulating system are highly dependent from temperature.In the other part, the paper presents experimental results of the frequency diagnostic measurement for a real single-phase traction transformer 110/27 kV at different operating temperatures and states (with oil and without).Finally in the last part, the paper presents comparing frequency insulating measurements among several the same single-phase transformers 110/27 kV.https://pimi.bntu.by/jour/article/view/558transformerdiagnosticsinsulationpaperoil
collection DOAJ
language English
format Article
sources DOAJ
author M. Gutten
M. Šebok
D. Korenčiak
P. Brnčal
M. Kubiš
P. Żukowski
T. N. Koltunowicz
spellingShingle M. Gutten
M. Šebok
D. Korenčiak
P. Brnčal
M. Kubiš
P. Żukowski
T. N. Koltunowicz
Frequency Domain Diagnostics of Transformer Insulation
Pribory i Metody Izmerenij
transformer
diagnostics
insulation
paper
oil
author_facet M. Gutten
M. Šebok
D. Korenčiak
P. Brnčal
M. Kubiš
P. Żukowski
T. N. Koltunowicz
author_sort M. Gutten
title Frequency Domain Diagnostics of Transformer Insulation
title_short Frequency Domain Diagnostics of Transformer Insulation
title_full Frequency Domain Diagnostics of Transformer Insulation
title_fullStr Frequency Domain Diagnostics of Transformer Insulation
title_full_unstemmed Frequency Domain Diagnostics of Transformer Insulation
title_sort frequency domain diagnostics of transformer insulation
publisher Belarusian National Technical University
series Pribory i Metody Izmerenij
issn 2220-9506
2414-0473
publishDate 2019-12-01
description The first part of paper deals with the base information about diagnostics of power transformers. In this part are presented differently insulating methods, for example method of recovery voltage method, method of polarization and depolarization currents and chromatographic analysis.The second part of paper deals use of method of frequency domain spectroscopy for oil power transformers. This method is used in analysis insulating condition of power transformer with system of oil-paper. It was found, that the results of these tests are highly impacted by the operating temperature during the experimental measurement. Moisture and conductivity between insulating paper and oil in an insulating system are highly dependent from temperature.In the other part, the paper presents experimental results of the frequency diagnostic measurement for a real single-phase traction transformer 110/27 kV at different operating temperatures and states (with oil and without).Finally in the last part, the paper presents comparing frequency insulating measurements among several the same single-phase transformers 110/27 kV.
topic transformer
diagnostics
insulation
paper
oil
url https://pimi.bntu.by/jour/article/view/558
work_keys_str_mv AT mgutten frequencydomaindiagnosticsoftransformerinsulation
AT msebok frequencydomaindiagnosticsoftransformerinsulation
AT dkorenciak frequencydomaindiagnosticsoftransformerinsulation
AT pbrncal frequencydomaindiagnosticsoftransformerinsulation
AT mkubis frequencydomaindiagnosticsoftransformerinsulation
AT pzukowski frequencydomaindiagnosticsoftransformerinsulation
AT tnkoltunowicz frequencydomaindiagnosticsoftransformerinsulation
_version_ 1721252943287549952