Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates
This paper develops new practical rule-based energy management systems (EMSs) for typical grid-connected houses with solar photovoltaic (PV) and battery by considering different rates for purchasing and selling electricity. The EMSs are developed to supply the household’s loads and reduce operating...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-08-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/16/5028 |
id |
doaj-b5f74bf8d50e49558b5ccd3ad69322a5 |
---|---|
record_format |
Article |
spelling |
doaj-b5f74bf8d50e49558b5ccd3ad69322a52021-08-26T13:43:10ZengMDPI AGEnergies1996-10732021-08-01145028502810.3390/en14165028Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity RatesXincheng Pan0Rahmat Khezri1Amin Mahmoudi2Amirmehdi Yazdani3GM Shafiullah4Department STEM, University of South Australia, Adelaide, SA 5001, AustraliaCollege of Science and Engineering, Flinders University, Adelaide, SA 5042, AustraliaCollege of Science and Engineering, Flinders University, Adelaide, SA 5042, AustraliaDiscipline of Engineering and Energy, College of Science, Health, Engineering and Education, Murdoch University, Perth, WA 6150, AustraliaDiscipline of Engineering and Energy, College of Science, Health, Engineering and Education, Murdoch University, Perth, WA 6150, AustraliaThis paper develops new practical rule-based energy management systems (EMSs) for typical grid-connected houses with solar photovoltaic (PV) and battery by considering different rates for purchasing and selling electricity. The EMSs are developed to supply the household’s loads and reduce operating costs of the system based on different options of flat and time-of-use (ToU) rates for buying and selling electricity prices. Four different options are evaluated and compared in this study: (1) Flat-Flat, (2) ToU-Flat, (3) Flat-ToU, and (4) ToU-ToU. The operation cost is calculated based on the electricity exchange with the main grid, the equivalent cost of PV generation, as well as the degradation cost of battery storage. The operation of the grid-connected house with rooftop solar PV and battery is evaluated for a sunny week in summer and a cloudy week in winter to investigate the proper performance for high and low generations of PV. While the developed rule-based EMS are generic and can be applied for any case studies, a grid-connected house in Australia is examined. For this purpose, real data of solar radiation, air temperature, electricity consumption, and electricity rates are used. It is found that the ToU-Flat option has the lowest operating cost for the customers.https://www.mdpi.com/1996-1073/14/16/5028Australiabattery energy storageelectricity cost analysisflat electricity rategrid-connected householdhome energy management system |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Xincheng Pan Rahmat Khezri Amin Mahmoudi Amirmehdi Yazdani GM Shafiullah |
spellingShingle |
Xincheng Pan Rahmat Khezri Amin Mahmoudi Amirmehdi Yazdani GM Shafiullah Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates Energies Australia battery energy storage electricity cost analysis flat electricity rate grid-connected household home energy management system |
author_facet |
Xincheng Pan Rahmat Khezri Amin Mahmoudi Amirmehdi Yazdani GM Shafiullah |
author_sort |
Xincheng Pan |
title |
Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates |
title_short |
Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates |
title_full |
Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates |
title_fullStr |
Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates |
title_full_unstemmed |
Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates |
title_sort |
energy management systems for grid-connected houses with solar pv and battery by considering flat and time-of-use electricity rates |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2021-08-01 |
description |
This paper develops new practical rule-based energy management systems (EMSs) for typical grid-connected houses with solar photovoltaic (PV) and battery by considering different rates for purchasing and selling electricity. The EMSs are developed to supply the household’s loads and reduce operating costs of the system based on different options of flat and time-of-use (ToU) rates for buying and selling electricity prices. Four different options are evaluated and compared in this study: (1) Flat-Flat, (2) ToU-Flat, (3) Flat-ToU, and (4) ToU-ToU. The operation cost is calculated based on the electricity exchange with the main grid, the equivalent cost of PV generation, as well as the degradation cost of battery storage. The operation of the grid-connected house with rooftop solar PV and battery is evaluated for a sunny week in summer and a cloudy week in winter to investigate the proper performance for high and low generations of PV. While the developed rule-based EMS are generic and can be applied for any case studies, a grid-connected house in Australia is examined. For this purpose, real data of solar radiation, air temperature, electricity consumption, and electricity rates are used. It is found that the ToU-Flat option has the lowest operating cost for the customers. |
topic |
Australia battery energy storage electricity cost analysis flat electricity rate grid-connected household home energy management system |
url |
https://www.mdpi.com/1996-1073/14/16/5028 |
work_keys_str_mv |
AT xinchengpan energymanagementsystemsforgridconnectedhouseswithsolarpvandbatterybyconsideringflatandtimeofuseelectricityrates AT rahmatkhezri energymanagementsystemsforgridconnectedhouseswithsolarpvandbatterybyconsideringflatandtimeofuseelectricityrates AT aminmahmoudi energymanagementsystemsforgridconnectedhouseswithsolarpvandbatterybyconsideringflatandtimeofuseelectricityrates AT amirmehdiyazdani energymanagementsystemsforgridconnectedhouseswithsolarpvandbatterybyconsideringflatandtimeofuseelectricityrates AT gmshafiullah energymanagementsystemsforgridconnectedhouseswithsolarpvandbatterybyconsideringflatandtimeofuseelectricityrates |
_version_ |
1721193736204976128 |