Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification

Purpose: To study factors affecting laser energy levels required for neodymium: yttrium aluminium garnet (Nd: YAG) laser capsulotomy and to evaluate whether any correlation exists between applied laser energy levels and complications. Methods: The present study examined 474 consecutive patients for...

Full description

Bibliographic Details
Main Authors: Rahul Bhargava, Prachi Kumar, Hemant Phogat, Kulbhushan Prakash Chaudhary
Format: Article
Language:English
Published: Knowledge E 2015-01-01
Series:Journal of Ophthalmic & Vision Research
Subjects:
Online Access:http://www.jovr.org/article.asp?issn=2008-322X;year=2015;volume=10;issue=1;spage=37;epage=42;aulast=Bhargava
id doaj-b5f071a58e064656b7480c09b17d3daa
record_format Article
spelling doaj-b5f071a58e064656b7480c09b17d3daa2020-11-25T01:44:33ZengKnowledge EJournal of Ophthalmic & Vision Research2008-322X2015-01-01101374210.4103/2008-322X.156101Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacificationRahul BhargavaPrachi KumarHemant PhogatKulbhushan Prakash ChaudharyPurpose: To study factors affecting laser energy levels required for neodymium: yttrium aluminium garnet (Nd: YAG) laser capsulotomy and to evaluate whether any correlation exists between applied laser energy levels and complications. Methods: The present study examined 474 consecutive patients for a number of factors including age, type of posterior capsule opacification (PCO), material and fixation of intraocular lens (IOL) and complication rates, versus energy levels used for Nd: YAG laser capsulotomy. Results: Mean patient age was 55.6 ± 8.7 years and mean follow up period was 22.9 ± 4.5 months. IOL biomaterial (KW ANOVA; P = 0.173) and patient′s age (P = 0.246) did not significantly influence total laser energy requirement for capsulotomy. However, total laser energy levels were significantly higher (KW ANOVA; P < 0.001) with fibro-membranous and fibrous subtypes of PCO. Complications such as IOL pitting, intraocular pressure (IOP) elevation, uveitis, retinal detachment (RD) and cystoid macular edema (CME) were significantly more common when higher energy levels was used. The mean total energy in patients with RD was 77.7 ± 17.7 mJ as compared to 43.4 ± 26.9 mJ in the rest of the cohort. RD was more common in patients with higher axial length [n = 7 (63%)] (P < 0.001). Conclusion: Type of PCO significantly influenced laser energy levels required for capsulotomy, whereas IOL biomaterial and fixation did not. Complications such as IOL pitting, uveitis, IOP elevation, RD and CME was significantly more common when total laser energy was higher. It is recommended that the lowest possible single pulse laser energy be used for capsulotomy to minimize complications.http://www.jovr.org/article.asp?issn=2008-322X;year=2015;volume=10;issue=1;spage=37;epage=42;aulast=BhargavaIntraocular Lens; Laser Capsulotomy; Posterior Capsule Opacification
collection DOAJ
language English
format Article
sources DOAJ
author Rahul Bhargava
Prachi Kumar
Hemant Phogat
Kulbhushan Prakash Chaudhary
spellingShingle Rahul Bhargava
Prachi Kumar
Hemant Phogat
Kulbhushan Prakash Chaudhary
Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
Journal of Ophthalmic & Vision Research
Intraocular Lens; Laser Capsulotomy; Posterior Capsule Opacification
author_facet Rahul Bhargava
Prachi Kumar
Hemant Phogat
Kulbhushan Prakash Chaudhary
author_sort Rahul Bhargava
title Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
title_short Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
title_full Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
title_fullStr Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
title_full_unstemmed Neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
title_sort neodymium-yttrium aluminium garnet laser capsulotomy energy levels for posterior capsule opacification
publisher Knowledge E
series Journal of Ophthalmic & Vision Research
issn 2008-322X
publishDate 2015-01-01
description Purpose: To study factors affecting laser energy levels required for neodymium: yttrium aluminium garnet (Nd: YAG) laser capsulotomy and to evaluate whether any correlation exists between applied laser energy levels and complications. Methods: The present study examined 474 consecutive patients for a number of factors including age, type of posterior capsule opacification (PCO), material and fixation of intraocular lens (IOL) and complication rates, versus energy levels used for Nd: YAG laser capsulotomy. Results: Mean patient age was 55.6 ± 8.7 years and mean follow up period was 22.9 ± 4.5 months. IOL biomaterial (KW ANOVA; P = 0.173) and patient′s age (P = 0.246) did not significantly influence total laser energy requirement for capsulotomy. However, total laser energy levels were significantly higher (KW ANOVA; P < 0.001) with fibro-membranous and fibrous subtypes of PCO. Complications such as IOL pitting, intraocular pressure (IOP) elevation, uveitis, retinal detachment (RD) and cystoid macular edema (CME) were significantly more common when higher energy levels was used. The mean total energy in patients with RD was 77.7 ± 17.7 mJ as compared to 43.4 ± 26.9 mJ in the rest of the cohort. RD was more common in patients with higher axial length [n = 7 (63%)] (P < 0.001). Conclusion: Type of PCO significantly influenced laser energy levels required for capsulotomy, whereas IOL biomaterial and fixation did not. Complications such as IOL pitting, uveitis, IOP elevation, RD and CME was significantly more common when total laser energy was higher. It is recommended that the lowest possible single pulse laser energy be used for capsulotomy to minimize complications.
topic Intraocular Lens; Laser Capsulotomy; Posterior Capsule Opacification
url http://www.jovr.org/article.asp?issn=2008-322X;year=2015;volume=10;issue=1;spage=37;epage=42;aulast=Bhargava
work_keys_str_mv AT rahulbhargava neodymiumyttriumaluminiumgarnetlasercapsulotomyenergylevelsforposteriorcapsuleopacification
AT prachikumar neodymiumyttriumaluminiumgarnetlasercapsulotomyenergylevelsforposteriorcapsuleopacification
AT hemantphogat neodymiumyttriumaluminiumgarnetlasercapsulotomyenergylevelsforposteriorcapsuleopacification
AT kulbhushanprakashchaudhary neodymiumyttriumaluminiumgarnetlasercapsulotomyenergylevelsforposteriorcapsuleopacification
_version_ 1725027997843456000