Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses

Rubber-bearing isolation is one of the most successfully and widely used isolation technologies to provide lateral flexibility and energy dissipation capacity for reducing structural vibration and protecting the superstructure from damage. The seismic performance of the base-isolated structures part...

Full description

Bibliographic Details
Main Authors: Xiongjun Yang, Han Su, Lijun Liu, Ying Lei
Format: Article
Language:English
Published: SAGE Publishing 2020-09-01
Series:Journal of Low Frequency Noise, Vibration and Active Control
Online Access:https://doi.org/10.1177/1461348419843385
id doaj-b5e997fa4fe6499d948ca36911f881a2
record_format Article
spelling doaj-b5e997fa4fe6499d948ca36911f881a22020-11-25T03:16:31ZengSAGE PublishingJournal of Low Frequency Noise, Vibration and Active Control1461-34842048-40462020-09-013910.1177/1461348419843385Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responsesXiongjun YangHan SuLijun LiuYing LeiRubber-bearing isolation is one of the most successfully and widely used isolation technologies to provide lateral flexibility and energy dissipation capacity for reducing structural vibration and protecting the superstructure from damage. The seismic performance of the base-isolated structures partly depends on the nonlinear characteristics of the base isolation system. However, it is hard to establish proper mathematical models for the nonlinear hysteretic behaviors of base isolation due to the complexities of nonlinearities. Consequently, it is strongly desired to develop model-free methodologies for the nonlinear hysteretic performance identification with no assumption on the nonlinear hysteretic models of base isolation. In this paper, a novel method is proposed for this purpose. Firstly, the base isolation is in the linear state when the structure is under the weak earthquake, the restoring force is only provided by linear stiffness and viscous damping of base isolation, and the structural physical parameters can be estimated based on the extended Kalman filter approach. Then, the base isolation is in the nonlinear state when the structure is under the strong earthquake. The nonlinear hysteretic restoring forces from base isolation are treated as “unknown fictitious inputs” to the corresponding structural systems without base isolation. The generalized Kalman filter with unknown input algorithm is adopted for the simultaneous identification of the corresponding structural systems and the hysteretic restoring force of base isolation using only partial structural responses. No information about the structure is needed, and the responses at the location of the base isolation are not required, the proposed method is capable of identifying nonlinear characteristics of base isolation by the direct use of partial structural dynamic response. To validate the performances of the proposed method, some numerical simulation examples of identifying nonlinear hysteretic restoring forces of base isolation in different models are used.https://doi.org/10.1177/1461348419843385
collection DOAJ
language English
format Article
sources DOAJ
author Xiongjun Yang
Han Su
Lijun Liu
Ying Lei
spellingShingle Xiongjun Yang
Han Su
Lijun Liu
Ying Lei
Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
Journal of Low Frequency Noise, Vibration and Active Control
author_facet Xiongjun Yang
Han Su
Lijun Liu
Ying Lei
author_sort Xiongjun Yang
title Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
title_short Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
title_full Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
title_fullStr Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
title_full_unstemmed Identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
title_sort identification of the nonlinear characteristics of rubber bearings in model-free base-isolated buildings using partial measurements of seismic responses
publisher SAGE Publishing
series Journal of Low Frequency Noise, Vibration and Active Control
issn 1461-3484
2048-4046
publishDate 2020-09-01
description Rubber-bearing isolation is one of the most successfully and widely used isolation technologies to provide lateral flexibility and energy dissipation capacity for reducing structural vibration and protecting the superstructure from damage. The seismic performance of the base-isolated structures partly depends on the nonlinear characteristics of the base isolation system. However, it is hard to establish proper mathematical models for the nonlinear hysteretic behaviors of base isolation due to the complexities of nonlinearities. Consequently, it is strongly desired to develop model-free methodologies for the nonlinear hysteretic performance identification with no assumption on the nonlinear hysteretic models of base isolation. In this paper, a novel method is proposed for this purpose. Firstly, the base isolation is in the linear state when the structure is under the weak earthquake, the restoring force is only provided by linear stiffness and viscous damping of base isolation, and the structural physical parameters can be estimated based on the extended Kalman filter approach. Then, the base isolation is in the nonlinear state when the structure is under the strong earthquake. The nonlinear hysteretic restoring forces from base isolation are treated as “unknown fictitious inputs” to the corresponding structural systems without base isolation. The generalized Kalman filter with unknown input algorithm is adopted for the simultaneous identification of the corresponding structural systems and the hysteretic restoring force of base isolation using only partial structural responses. No information about the structure is needed, and the responses at the location of the base isolation are not required, the proposed method is capable of identifying nonlinear characteristics of base isolation by the direct use of partial structural dynamic response. To validate the performances of the proposed method, some numerical simulation examples of identifying nonlinear hysteretic restoring forces of base isolation in different models are used.
url https://doi.org/10.1177/1461348419843385
work_keys_str_mv AT xiongjunyang identificationofthenonlinearcharacteristicsofrubberbearingsinmodelfreebaseisolatedbuildingsusingpartialmeasurementsofseismicresponses
AT hansu identificationofthenonlinearcharacteristicsofrubberbearingsinmodelfreebaseisolatedbuildingsusingpartialmeasurementsofseismicresponses
AT lijunliu identificationofthenonlinearcharacteristicsofrubberbearingsinmodelfreebaseisolatedbuildingsusingpartialmeasurementsofseismicresponses
AT yinglei identificationofthenonlinearcharacteristicsofrubberbearingsinmodelfreebaseisolatedbuildingsusingpartialmeasurementsofseismicresponses
_version_ 1724635728683466752