PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
Abstract Background As the only arterial structure of which two main arteries merged into one, the vertebro-basilar (VA-BA) system is one of the favorite sites of cerebral atherosclerotic plaques. The aim of this study was to investigate the detailed hemodynamics characteristics in the VA-BA system....
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2019-09-01
|
Series: | BioMedical Engineering OnLine |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1186/s12938-019-0711-9 |
id |
doaj-b5a1e31999bd47dd950a28d43f2932b4 |
---|---|
record_format |
Article |
spelling |
doaj-b5a1e31999bd47dd950a28d43f2932b42020-11-25T02:25:03ZengBMCBioMedical Engineering OnLine1475-925X2019-09-0118111910.1186/s12938-019-0711-9PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junctionGuangyu Zhu0Yuan Wei1Qi Yuan2Jian Yang3Joon Hock Yeo4School of Energy and Power Engineering, Xi’an Jiaotong UniversitySchool of Energy and Power Engineering, Xi’an Jiaotong UniversitySchool of Energy and Power Engineering, Xi’an Jiaotong UniversityDepartment of Radiology and Medical Imaging, The First Affiliated Hospital of Xi’an Jiaotong UniversitySchool of Mechanical and Aerospace Engineering, Nanyang Technological UniversityAbstract Background As the only arterial structure of which two main arteries merged into one, the vertebro-basilar (VA-BA) system is one of the favorite sites of cerebral atherosclerotic plaques. The aim of this study was to investigate the detailed hemodynamics characteristics in the VA-BA system. Methods A scale-up subject-specific flow phantom of VA-BA system was fabricated based on the computed tomography angiography (CTA) scanning images of a healthy adult. Flow fields in eight axial planes and six radial planes were measured and analyzed by using particle image velocimetry (PIV) under steady flow conditions of $${Re}=300$$ Re=300 , $${Re}=500$$ Re=500 . A water–glycerin mixture was used as the working fluid. Results The flow in the current model exhibited highly three-dimensional characteristics. The confluence of VAs flow formed bimodal velocity distribution near the confluence apex. Due to the asymmetrical structural configuration, the bimodal velocity profile skewed towards left, and sharper peaks were observed under higher Reynolds condition. Secondary flow characterized by two vortices formed in the radial planes where 10 mm downstream the confluence apex and persists along the BA under both Reynolds numbers. The strength of secondary flow under $${Re}=500$$ Re=500 is around 8% higher than that under $${Re}=300$$ Re=300 , and decayed nonlinearly along the flow direction. In addition, a low momentum recirculation region induced by boundary layer separation was observed near the confluence apex. The wall shear stress (WSS) in the recirculation area was found to be lower than 0.4 Pa. This region coincides well with the preferential site of vascular lesions in the VA-BA system. Conclusions This preliminary study verified that the subject-specific in-vitro experiment is capable of reflecting the detailed flow features in the VA-BA system. The findings from this study may help to expand the understanding of the hemodynamics in the VA-BA system, and further clarifying the mechanism that underlying the localization of vascular lesions.http://link.springer.com/article/10.1186/s12938-019-0711-9PIVIn-vitroHemodynamicsVA-BA |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Guangyu Zhu Yuan Wei Qi Yuan Jian Yang Joon Hock Yeo |
spellingShingle |
Guangyu Zhu Yuan Wei Qi Yuan Jian Yang Joon Hock Yeo PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction BioMedical Engineering OnLine PIV In-vitro Hemodynamics VA-BA |
author_facet |
Guangyu Zhu Yuan Wei Qi Yuan Jian Yang Joon Hock Yeo |
author_sort |
Guangyu Zhu |
title |
PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction |
title_short |
PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction |
title_full |
PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction |
title_fullStr |
PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction |
title_full_unstemmed |
PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction |
title_sort |
piv investigation of the flow fields in subject-specific vertebro-basilar (va-ba) junction |
publisher |
BMC |
series |
BioMedical Engineering OnLine |
issn |
1475-925X |
publishDate |
2019-09-01 |
description |
Abstract Background As the only arterial structure of which two main arteries merged into one, the vertebro-basilar (VA-BA) system is one of the favorite sites of cerebral atherosclerotic plaques. The aim of this study was to investigate the detailed hemodynamics characteristics in the VA-BA system. Methods A scale-up subject-specific flow phantom of VA-BA system was fabricated based on the computed tomography angiography (CTA) scanning images of a healthy adult. Flow fields in eight axial planes and six radial planes were measured and analyzed by using particle image velocimetry (PIV) under steady flow conditions of $${Re}=300$$ Re=300 , $${Re}=500$$ Re=500 . A water–glycerin mixture was used as the working fluid. Results The flow in the current model exhibited highly three-dimensional characteristics. The confluence of VAs flow formed bimodal velocity distribution near the confluence apex. Due to the asymmetrical structural configuration, the bimodal velocity profile skewed towards left, and sharper peaks were observed under higher Reynolds condition. Secondary flow characterized by two vortices formed in the radial planes where 10 mm downstream the confluence apex and persists along the BA under both Reynolds numbers. The strength of secondary flow under $${Re}=500$$ Re=500 is around 8% higher than that under $${Re}=300$$ Re=300 , and decayed nonlinearly along the flow direction. In addition, a low momentum recirculation region induced by boundary layer separation was observed near the confluence apex. The wall shear stress (WSS) in the recirculation area was found to be lower than 0.4 Pa. This region coincides well with the preferential site of vascular lesions in the VA-BA system. Conclusions This preliminary study verified that the subject-specific in-vitro experiment is capable of reflecting the detailed flow features in the VA-BA system. The findings from this study may help to expand the understanding of the hemodynamics in the VA-BA system, and further clarifying the mechanism that underlying the localization of vascular lesions. |
topic |
PIV In-vitro Hemodynamics VA-BA |
url |
http://link.springer.com/article/10.1186/s12938-019-0711-9 |
work_keys_str_mv |
AT guangyuzhu pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction AT yuanwei pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction AT qiyuan pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction AT jianyang pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction AT joonhockyeo pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction |
_version_ |
1724853004194021376 |