Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents
<abstract language="eng">This work discusses an analytical procedure for analysis of sulfur compounds in treated petroleum refinery gaseous effluents using a sulfur chemiluminescence detector with dual plasma burner (SCD-DP). Calibration was accomplished by using standards and gaseou...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Química
2010-01-01
|
Series: | Química Nova |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400035 |
id |
doaj-b587e688a07047349450a271e4f96375 |
---|---|
record_format |
Article |
spelling |
doaj-b587e688a07047349450a271e4f963752020-11-24T22:31:26ZengSociedade Brasileira de QuímicaQuímica Nova0100-40421678-70642010-01-0133495796310.1590/S0100-40422010000400035Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluentsJúlio Carlos AfonsoKátia da Silva Pereira<abstract language="eng">This work discusses an analytical procedure for analysis of sulfur compounds in treated petroleum refinery gaseous effluents using a sulfur chemiluminescence detector with dual plasma burner (SCD-DP). Calibration was accomplished by using standards and gaseous streams of known concentration of sulfur compounds. The response factors agree with the calibration table of ASTM standard D 5504 (2008). The detection range for sulfur compounds is in μg m-3. The analytical procedure allowed the construction of a chromatographic chart of sulfur compounds present in several refinery gaseous effluents. SO2 was the most difficult compound to be determined because of its high reactivity.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400035sulfur compoundschemiluminescencegaseous effluents |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Júlio Carlos Afonso Kátia da Silva Pereira |
spellingShingle |
Júlio Carlos Afonso Kátia da Silva Pereira Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents Química Nova sulfur compounds chemiluminescence gaseous effluents |
author_facet |
Júlio Carlos Afonso Kátia da Silva Pereira |
author_sort |
Júlio Carlos Afonso |
title |
Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents |
title_short |
Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents |
title_full |
Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents |
title_fullStr |
Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents |
title_full_unstemmed |
Análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo Analysis of sulfur compounds in petroleum refinery gaseous effluents |
title_sort |
análise de compostos sulfurados em efluentes gasosos de refinaria de petróleo analysis of sulfur compounds in petroleum refinery gaseous effluents |
publisher |
Sociedade Brasileira de Química |
series |
Química Nova |
issn |
0100-4042 1678-7064 |
publishDate |
2010-01-01 |
description |
<abstract language="eng">This work discusses an analytical procedure for analysis of sulfur compounds in treated petroleum refinery gaseous effluents using a sulfur chemiluminescence detector with dual plasma burner (SCD-DP). Calibration was accomplished by using standards and gaseous streams of known concentration of sulfur compounds. The response factors agree with the calibration table of ASTM standard D 5504 (2008). The detection range for sulfur compounds is in μg m-3. The analytical procedure allowed the construction of a chromatographic chart of sulfur compounds present in several refinery gaseous effluents. SO2 was the most difficult compound to be determined because of its high reactivity. |
topic |
sulfur compounds chemiluminescence gaseous effluents |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400035 |
work_keys_str_mv |
AT juliocarlosafonso analisedecompostossulfuradosemefluentesgasososderefinariadepetroleoanalysisofsulfurcompoundsinpetroleumrefinerygaseouseffluents AT katiadasilvapereira analisedecompostossulfuradosemefluentesgasososderefinariadepetroleoanalysisofsulfurcompoundsinpetroleumrefinerygaseouseffluents |
_version_ |
1725737136777330688 |