Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents

Activated Partial Thromboplastin Time (APTT) is a hematological examination to identify hemostatic abnormalities. This study aimed to compare the performance evaluation of four APTT reagents, i.e., CK Prest, Pathromtin SL, Actin SL, and Cephascreen. The methods used were photo optical, percent detec...

Full description

Bibliographic Details
Main Authors: Peppi Z. Yuzaqi, Eli Halimah, Tatat Noviani
Format: Article
Language:English
Published: Universitas Padjadjaran 2018-08-01
Series:Pharmacology and Clinical Pharmacy Research
Online Access:http://jurnal.unpad.ac.id/pcpr/article/view/18103
id doaj-b56d8a141cdb45089336e63203abaeb7
record_format Article
spelling doaj-b56d8a141cdb45089336e63203abaeb72020-11-24T21:01:22ZengUniversitas PadjadjaranPharmacology and Clinical Pharmacy Research2527-73322614-00202018-08-0132334010.15416/pcpr.v3i2.181039299Performance Evaluation of Four Activated Partial Thromboplastin Time ReagentsPeppi Z. Yuzaqi0Eli HalimahTatat NovianiDepartment of Pharmacology and Clinical Pharmacy, Faculty of Pharmacy, Universitas Padjadjaran, Jatinangor, West Java, Indonesia.Activated Partial Thromboplastin Time (APTT) is a hematological examination to identify hemostatic abnormalities. This study aimed to compare the performance evaluation of four APTT reagents, i.e., CK Prest, Pathromtin SL, Actin SL, and Cephascreen. The methods used were photo optical, percent detection, and viscosity-based detection system (VDS). The analysis was performed on blood specimen of 43 subjects. The results indicated that the accuracy and precision in normal plasma control using C. K. Prest reagent in Coag-A-Mate® MTX II were d% -0.605 and CV% 2.252%, Pathromtin SL reagent in CA 560® (Sysmex®) were d% 6.9345 and CV%1.687, Actin FSL reagent in CA 560® (Sysmex®) were d% -1.51 and CV% 1.74, and Cephascreeen reagent in STA Compact® were d% 10.81 and CV% 1.60. The accuracy and precision in pathological plasma control using Pathromtin SL reagent in CA 560® (Sysmex®) were d% -1,11 and CV% 8.82, Cephascreen reagent in STA Compact® were d% 4.64 and CV% 2.72. The coefficient of correlation between C. K. Prest reagent and Pathromtin SL reagent was 0.880 with the regresion equation y=2.31x–33.70. The coefficient of correlation between C. K. Prest reagent and Actin FSL reagent was 0.986 with the regretion equation y=0.78x+2.93. The coefficient of correlation between C. K. Prest reagent and Cephascreen reagent was 0.987 with the regretion equation y=1.70x–3.97. In conclusion, the best precision was obtained from Cephascreen reagents in STA compact®devices for both normal and pathologic control plasma, with eligible accuracy. Keywords : Activated Partial Thromboplastin Time (APTT), Photo-optical, Viscosity-based Detection System (VDS)http://jurnal.unpad.ac.id/pcpr/article/view/18103
collection DOAJ
language English
format Article
sources DOAJ
author Peppi Z. Yuzaqi
Eli Halimah
Tatat Noviani
spellingShingle Peppi Z. Yuzaqi
Eli Halimah
Tatat Noviani
Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents
Pharmacology and Clinical Pharmacy Research
author_facet Peppi Z. Yuzaqi
Eli Halimah
Tatat Noviani
author_sort Peppi Z. Yuzaqi
title Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents
title_short Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents
title_full Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents
title_fullStr Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents
title_full_unstemmed Performance Evaluation of Four Activated Partial Thromboplastin Time Reagents
title_sort performance evaluation of four activated partial thromboplastin time reagents
publisher Universitas Padjadjaran
series Pharmacology and Clinical Pharmacy Research
issn 2527-7332
2614-0020
publishDate 2018-08-01
description Activated Partial Thromboplastin Time (APTT) is a hematological examination to identify hemostatic abnormalities. This study aimed to compare the performance evaluation of four APTT reagents, i.e., CK Prest, Pathromtin SL, Actin SL, and Cephascreen. The methods used were photo optical, percent detection, and viscosity-based detection system (VDS). The analysis was performed on blood specimen of 43 subjects. The results indicated that the accuracy and precision in normal plasma control using C. K. Prest reagent in Coag-A-Mate® MTX II were d% -0.605 and CV% 2.252%, Pathromtin SL reagent in CA 560® (Sysmex®) were d% 6.9345 and CV%1.687, Actin FSL reagent in CA 560® (Sysmex®) were d% -1.51 and CV% 1.74, and Cephascreeen reagent in STA Compact® were d% 10.81 and CV% 1.60. The accuracy and precision in pathological plasma control using Pathromtin SL reagent in CA 560® (Sysmex®) were d% -1,11 and CV% 8.82, Cephascreen reagent in STA Compact® were d% 4.64 and CV% 2.72. The coefficient of correlation between C. K. Prest reagent and Pathromtin SL reagent was 0.880 with the regresion equation y=2.31x–33.70. The coefficient of correlation between C. K. Prest reagent and Actin FSL reagent was 0.986 with the regretion equation y=0.78x+2.93. The coefficient of correlation between C. K. Prest reagent and Cephascreen reagent was 0.987 with the regretion equation y=1.70x–3.97. In conclusion, the best precision was obtained from Cephascreen reagents in STA compact®devices for both normal and pathologic control plasma, with eligible accuracy. Keywords : Activated Partial Thromboplastin Time (APTT), Photo-optical, Viscosity-based Detection System (VDS)
url http://jurnal.unpad.ac.id/pcpr/article/view/18103
work_keys_str_mv AT peppizyuzaqi performanceevaluationoffouractivatedpartialthromboplastintimereagents
AT elihalimah performanceevaluationoffouractivatedpartialthromboplastintimereagents
AT tatatnoviani performanceevaluationoffouractivatedpartialthromboplastintimereagents
_version_ 1716778203216871424