Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil
Objective To suggest a national value for the diagnostic reference level (DRL) in terms of activity in MBq.kg–1, for nuclear medicine procedures with fluorodeoxyglucose (18F-FDG) in whole body positron emission tomography (PET) scans of adult patients. Materials and Methods A survey on values of 1...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
2013-09-01
|
Series: | Radiologia Brasileira |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000500284&lng=en&tlng=en |
id |
doaj-b5601dd7430b483e974ac1a44e2a8a93 |
---|---|
record_format |
Article |
spelling |
doaj-b5601dd7430b483e974ac1a44e2a8a932020-11-24T23:44:05ZengColégio Brasileiro de Radiologia e Diagnóstico por ImagemRadiologia Brasileira1678-70992013-09-0146528428910.1590/S0100-39842013000500004S0100-39842013000500284Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in BrazilCassio Miri OliveiraLidia Vasconcellos de SaThessa Cristina AlonsoTeogenes Augusto da SilvaObjective To suggest a national value for the diagnostic reference level (DRL) in terms of activity in MBq.kg–1, for nuclear medicine procedures with fluorodeoxyglucose (18F-FDG) in whole body positron emission tomography (PET) scans of adult patients. Materials and Methods A survey on values of 18F-FDG activity administered in Brazilian clinics was undertaken by means of a questionnaire including questions about number and manufacturer of the installed equipment, model and detector type. The suggested DRL value was based on the calculation of the third quartile of the activity values distribution reported by the clinics. Results Among the surveyed Brazilian clinics, 58% responded completely or partially the questionnaire; and the results demonstrated variation of up to 100% in the reported radiopharmaceutical activity. The suggested DRL for 18F-FDG/PET activity was 5.54 MBq.kg–1 (0.149 mCi.kg–1). Conclusion The present study has demonstrated the lack of standardization in administered radiopharmaceutical activities for PET procedures in Brazil, corroborating the necessity of an official DRL value to be adopted in the country. The suggested DLR value demonstrates that there is room for optimization of the procedures and 18F-FDG/PET activities administered in Brazilian clinics to reduce the doses delivered to patients. It is important to highlight that this value should be continually revised and optimized at least every five years.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000500284&lng=en&tlng=enNuclear medicinePositron emission tomographyDiagnostic reference levelRadiopharmaceutical 18F-FDG |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Cassio Miri Oliveira Lidia Vasconcellos de Sa Thessa Cristina Alonso Teogenes Augusto da Silva |
spellingShingle |
Cassio Miri Oliveira Lidia Vasconcellos de Sa Thessa Cristina Alonso Teogenes Augusto da Silva Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil Radiologia Brasileira Nuclear medicine Positron emission tomography Diagnostic reference level Radiopharmaceutical 18F-FDG |
author_facet |
Cassio Miri Oliveira Lidia Vasconcellos de Sa Thessa Cristina Alonso Teogenes Augusto da Silva |
author_sort |
Cassio Miri Oliveira |
title |
Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil |
title_short |
Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil |
title_full |
Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil |
title_fullStr |
Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil |
title_full_unstemmed |
Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil |
title_sort |
suggestion of a national diagnostic reference level for 18f-fdg/pet scans in adult cancer patients in brazil |
publisher |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
series |
Radiologia Brasileira |
issn |
1678-7099 |
publishDate |
2013-09-01 |
description |
Objective To suggest a national value for the diagnostic reference level (DRL) in terms of activity in MBq.kg–1, for nuclear medicine procedures with fluorodeoxyglucose (18F-FDG) in whole body positron emission tomography (PET) scans of adult patients. Materials and Methods A survey on values of 18F-FDG activity administered in Brazilian clinics was undertaken by means of a questionnaire including questions about number and manufacturer of the installed equipment, model and detector type. The suggested DRL value was based on the calculation of the third quartile of the activity values distribution reported by the clinics. Results Among the surveyed Brazilian clinics, 58% responded completely or partially the questionnaire; and the results demonstrated variation of up to 100% in the reported radiopharmaceutical activity. The suggested DRL for 18F-FDG/PET activity was 5.54 MBq.kg–1 (0.149 mCi.kg–1). Conclusion The present study has demonstrated the lack of standardization in administered radiopharmaceutical activities for PET procedures in Brazil, corroborating the necessity of an official DRL value to be adopted in the country. The suggested DLR value demonstrates that there is room for optimization of the procedures and 18F-FDG/PET activities administered in Brazilian clinics to reduce the doses delivered to patients. It is important to highlight that this value should be continually revised and optimized at least every five years. |
topic |
Nuclear medicine Positron emission tomography Diagnostic reference level Radiopharmaceutical 18F-FDG |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000500284&lng=en&tlng=en |
work_keys_str_mv |
AT cassiomirioliveira suggestionofanationaldiagnosticreferencelevelfor18ffdgpetscansinadultcancerpatientsinbrazil AT lidiavasconcellosdesa suggestionofanationaldiagnosticreferencelevelfor18ffdgpetscansinadultcancerpatientsinbrazil AT thessacristinaalonso suggestionofanationaldiagnosticreferencelevelfor18ffdgpetscansinadultcancerpatientsinbrazil AT teogenesaugustodasilva suggestionofanationaldiagnosticreferencelevelfor18ffdgpetscansinadultcancerpatientsinbrazil |
_version_ |
1725500099524558848 |