Assessment of indicators of efficiency of the steam-turbine mini-thermal power plants burning coal

In work results of calculations of main units of steam -turbine mini-thermal power plants of low power: 6, 11,4, 12, 20 and 25 MW intended for work in the autonomous mode are presented. On the basis of material, thermal and the exergy balances efficiency indicators – the exergy efficiency and specif...

Full description

Bibliographic Details
Main Authors: D. T. Nguyen, D. N. Fam, G. R. Mingaleeva
Format: Article
Language:English
Published: Kazan State Power Engineering University 2019-06-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/927