Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation

Introduction. The main purpose of this study is to develop an efficient technique for generating FE models of pelvic ring fractures that is capable of predicting possible failure regions of osteosynthesis with acceptable accuracy. Methods. Patient-specific FE models of two patients with osteoporotic...

Full description

Bibliographic Details
Main Authors: Vickie Shim, Andreas Höch, Ronny Grunert, Steffen Peldschus, Jörg Böhme
Format: Article
Language:English
Published: Hindawi Limited 2017-01-01
Series:Computational and Mathematical Methods in Medicine
Online Access:http://dx.doi.org/10.1155/2017/9403821
id doaj-b4e0636ee550448bb5f6bb3a9f6c89ba
record_format Article
spelling doaj-b4e0636ee550448bb5f6bb3a9f6c89ba2020-11-24T23:41:26ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182017-01-01201710.1155/2017/94038219403821Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture FixationVickie Shim0Andreas Höch1Ronny Grunert2Steffen Peldschus3Jörg Böhme4Auckland Bioengineering Institute, University of Auckland, 70 Symonds Street, Auckland, New ZealandDepartment of Trauma, Plastic and Reconstructive Surgery, University of Leipzig, Liebigstr. 20, 04103 Leipzig, GermanyDepartment of Trauma, Plastic and Reconstructive Surgery, University of Leipzig, Liebigstr. 20, 04103 Leipzig, GermanyInstitute of Forensic Medicine, Ludwig-Maximilians-University Munich, Munich, GermanyDepartment of Trauma, Plastic and Reconstructive Surgery, University of Leipzig, Liebigstr. 20, 04103 Leipzig, GermanyIntroduction. The main purpose of this study is to develop an efficient technique for generating FE models of pelvic ring fractures that is capable of predicting possible failure regions of osteosynthesis with acceptable accuracy. Methods. Patient-specific FE models of two patients with osteoporotic pelvic fractures were generated. A validated FE model of an uninjured pelvis from our previous study was used as a master model. Then, fracture morphologies and implant positions defined by a trauma surgeon in the preoperative CT were manually introduced as 3D splines to the master model. Four loading cases were used as boundary conditions. Regions of high stresses in the models were compared with actual locations of implant breakages and loosening identified from follow-up X-rays. Results. Model predictions and the actual clinical outcomes matched well. For Patient A, zones of increased tension and maximum stress coincided well with the actual locations of implant loosening. For Patient B, the model predicted accurately the loosening of the implant in the anterior region. Conclusion. Since a significant reduction in time and labour was achieved in our mesh generation technique, it can be considered as a viable option to be implemented as a part of the clinical routine to aid presurgical planning and postsurgical management of pelvic ring fracture patients.http://dx.doi.org/10.1155/2017/9403821
collection DOAJ
language English
format Article
sources DOAJ
author Vickie Shim
Andreas Höch
Ronny Grunert
Steffen Peldschus
Jörg Böhme
spellingShingle Vickie Shim
Andreas Höch
Ronny Grunert
Steffen Peldschus
Jörg Böhme
Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
Computational and Mathematical Methods in Medicine
author_facet Vickie Shim
Andreas Höch
Ronny Grunert
Steffen Peldschus
Jörg Böhme
author_sort Vickie Shim
title Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
title_short Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
title_full Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
title_fullStr Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
title_full_unstemmed Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
title_sort development of a patient-specific finite element model for predicting implant failure in pelvic ring fracture fixation
publisher Hindawi Limited
series Computational and Mathematical Methods in Medicine
issn 1748-670X
1748-6718
publishDate 2017-01-01
description Introduction. The main purpose of this study is to develop an efficient technique for generating FE models of pelvic ring fractures that is capable of predicting possible failure regions of osteosynthesis with acceptable accuracy. Methods. Patient-specific FE models of two patients with osteoporotic pelvic fractures were generated. A validated FE model of an uninjured pelvis from our previous study was used as a master model. Then, fracture morphologies and implant positions defined by a trauma surgeon in the preoperative CT were manually introduced as 3D splines to the master model. Four loading cases were used as boundary conditions. Regions of high stresses in the models were compared with actual locations of implant breakages and loosening identified from follow-up X-rays. Results. Model predictions and the actual clinical outcomes matched well. For Patient A, zones of increased tension and maximum stress coincided well with the actual locations of implant loosening. For Patient B, the model predicted accurately the loosening of the implant in the anterior region. Conclusion. Since a significant reduction in time and labour was achieved in our mesh generation technique, it can be considered as a viable option to be implemented as a part of the clinical routine to aid presurgical planning and postsurgical management of pelvic ring fracture patients.
url http://dx.doi.org/10.1155/2017/9403821
work_keys_str_mv AT vickieshim developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation
AT andreashoch developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation
AT ronnygrunert developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation
AT steffenpeldschus developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation
AT jorgbohme developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation
_version_ 1725507307786207232