Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation
Introduction. The main purpose of this study is to develop an efficient technique for generating FE models of pelvic ring fractures that is capable of predicting possible failure regions of osteosynthesis with acceptable accuracy. Methods. Patient-specific FE models of two patients with osteoporotic...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2017-01-01
|
Series: | Computational and Mathematical Methods in Medicine |
Online Access: | http://dx.doi.org/10.1155/2017/9403821 |
id |
doaj-b4e0636ee550448bb5f6bb3a9f6c89ba |
---|---|
record_format |
Article |
spelling |
doaj-b4e0636ee550448bb5f6bb3a9f6c89ba2020-11-24T23:41:26ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182017-01-01201710.1155/2017/94038219403821Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture FixationVickie Shim0Andreas Höch1Ronny Grunert2Steffen Peldschus3Jörg Böhme4Auckland Bioengineering Institute, University of Auckland, 70 Symonds Street, Auckland, New ZealandDepartment of Trauma, Plastic and Reconstructive Surgery, University of Leipzig, Liebigstr. 20, 04103 Leipzig, GermanyDepartment of Trauma, Plastic and Reconstructive Surgery, University of Leipzig, Liebigstr. 20, 04103 Leipzig, GermanyInstitute of Forensic Medicine, Ludwig-Maximilians-University Munich, Munich, GermanyDepartment of Trauma, Plastic and Reconstructive Surgery, University of Leipzig, Liebigstr. 20, 04103 Leipzig, GermanyIntroduction. The main purpose of this study is to develop an efficient technique for generating FE models of pelvic ring fractures that is capable of predicting possible failure regions of osteosynthesis with acceptable accuracy. Methods. Patient-specific FE models of two patients with osteoporotic pelvic fractures were generated. A validated FE model of an uninjured pelvis from our previous study was used as a master model. Then, fracture morphologies and implant positions defined by a trauma surgeon in the preoperative CT were manually introduced as 3D splines to the master model. Four loading cases were used as boundary conditions. Regions of high stresses in the models were compared with actual locations of implant breakages and loosening identified from follow-up X-rays. Results. Model predictions and the actual clinical outcomes matched well. For Patient A, zones of increased tension and maximum stress coincided well with the actual locations of implant loosening. For Patient B, the model predicted accurately the loosening of the implant in the anterior region. Conclusion. Since a significant reduction in time and labour was achieved in our mesh generation technique, it can be considered as a viable option to be implemented as a part of the clinical routine to aid presurgical planning and postsurgical management of pelvic ring fracture patients.http://dx.doi.org/10.1155/2017/9403821 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Vickie Shim Andreas Höch Ronny Grunert Steffen Peldschus Jörg Böhme |
spellingShingle |
Vickie Shim Andreas Höch Ronny Grunert Steffen Peldschus Jörg Böhme Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation Computational and Mathematical Methods in Medicine |
author_facet |
Vickie Shim Andreas Höch Ronny Grunert Steffen Peldschus Jörg Böhme |
author_sort |
Vickie Shim |
title |
Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation |
title_short |
Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation |
title_full |
Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation |
title_fullStr |
Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation |
title_full_unstemmed |
Development of a Patient-Specific Finite Element Model for Predicting Implant Failure in Pelvic Ring Fracture Fixation |
title_sort |
development of a patient-specific finite element model for predicting implant failure in pelvic ring fracture fixation |
publisher |
Hindawi Limited |
series |
Computational and Mathematical Methods in Medicine |
issn |
1748-670X 1748-6718 |
publishDate |
2017-01-01 |
description |
Introduction. The main purpose of this study is to develop an efficient technique for generating FE models of pelvic ring fractures that is capable of predicting possible failure regions of osteosynthesis with acceptable accuracy. Methods. Patient-specific FE models of two patients with osteoporotic pelvic fractures were generated. A validated FE model of an uninjured pelvis from our previous study was used as a master model. Then, fracture morphologies and implant positions defined by a trauma surgeon in the preoperative CT were manually introduced as 3D splines to the master model. Four loading cases were used as boundary conditions. Regions of high stresses in the models were compared with actual locations of implant breakages and loosening identified from follow-up X-rays. Results. Model predictions and the actual clinical outcomes matched well. For Patient A, zones of increased tension and maximum stress coincided well with the actual locations of implant loosening. For Patient B, the model predicted accurately the loosening of the implant in the anterior region. Conclusion. Since a significant reduction in time and labour was achieved in our mesh generation technique, it can be considered as a viable option to be implemented as a part of the clinical routine to aid presurgical planning and postsurgical management of pelvic ring fracture patients. |
url |
http://dx.doi.org/10.1155/2017/9403821 |
work_keys_str_mv |
AT vickieshim developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation AT andreashoch developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation AT ronnygrunert developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation AT steffenpeldschus developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation AT jorgbohme developmentofapatientspecificfiniteelementmodelforpredictingimplantfailureinpelvicringfracturefixation |
_version_ |
1725507307786207232 |