Absolute Baseline for Testing of Electronic Distance Meters
The paper deals with the construction and determination of coordinates of the absoluteEDMs baseline in a laboratory with 16 pillars with forced centring. Leica Absolute TrackerAT401 (standard deviation of distance measurement: 5 μ m, standard deviation of anglemeasurement: 0.15 mgon), which is desig...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Czech Technical University in Prague
2014-06-01
|
Series: | Geoinformatics FCE CTU |
Subjects: | |
Online Access: | https://ojs.cvut.cz/ojs/index.php/gi/article/view/2483 |
id |
doaj-b42e6af2032c45e6b8dfed547247b694 |
---|---|
record_format |
Article |
spelling |
doaj-b42e6af2032c45e6b8dfed547247b6942020-11-24T23:11:29ZengCzech Technical University in PragueGeoinformatics FCE CTU1802-26692014-06-01120283310.14311/gi.12.52283Absolute Baseline for Testing of Electronic Distance MetersJaroslav Braun0Filip Dvořáček1Martin Štroner2Czech Technical University in Prague, Faculty of Civil Engineering, Department of Special Geodesy, Thákurova 7, 16629 Praha 6, Czech RepublicCzech Technical University in Prague, Faculty of Civil Engineering, Department of Special Geodesy, Thákurova 7, 16629 Praha 6, Czech RepublicCzech Technical University in Prague, Faculty of Civil Engineering, Department of Special Geodesy, Thákurova 7, 16629 Praha 6, Czech RepublicThe paper deals with the construction and determination of coordinates of the absoluteEDMs baseline in a laboratory with 16 pillars with forced centring. Leica Absolute TrackerAT401 (standard deviation of distance measurement: 5 μ m, standard deviation of anglemeasurement: 0.15 mgon), which is designed for very accurate industrial measurements,was used for our purpose. Lengths between the baseline points were determined with astandard deviation of 0.02 mm. The baseline is used for determining systematic and randomerrors of distance meters and for accuracy of distance meters at short distances commonin engineering surveying for purposes of mechanical engineering.https://ojs.cvut.cz/ojs/index.php/gi/article/view/2483Absolute Tracker, EDM baseline, pillars, forced-centring plates, accurate lengths |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jaroslav Braun Filip Dvořáček Martin Štroner |
spellingShingle |
Jaroslav Braun Filip Dvořáček Martin Štroner Absolute Baseline for Testing of Electronic Distance Meters Geoinformatics FCE CTU Absolute Tracker, EDM baseline, pillars, forced-centring plates, accurate lengths |
author_facet |
Jaroslav Braun Filip Dvořáček Martin Štroner |
author_sort |
Jaroslav Braun |
title |
Absolute Baseline for Testing of Electronic Distance Meters |
title_short |
Absolute Baseline for Testing of Electronic Distance Meters |
title_full |
Absolute Baseline for Testing of Electronic Distance Meters |
title_fullStr |
Absolute Baseline for Testing of Electronic Distance Meters |
title_full_unstemmed |
Absolute Baseline for Testing of Electronic Distance Meters |
title_sort |
absolute baseline for testing of electronic distance meters |
publisher |
Czech Technical University in Prague |
series |
Geoinformatics FCE CTU |
issn |
1802-2669 |
publishDate |
2014-06-01 |
description |
The paper deals with the construction and determination of coordinates of the absoluteEDMs baseline in a laboratory with 16 pillars with forced centring. Leica Absolute TrackerAT401 (standard deviation of distance measurement: 5 μ m, standard deviation of anglemeasurement: 0.15 mgon), which is designed for very accurate industrial measurements,was used for our purpose. Lengths between the baseline points were determined with astandard deviation of 0.02 mm. The baseline is used for determining systematic and randomerrors of distance meters and for accuracy of distance meters at short distances commonin engineering surveying for purposes of mechanical engineering. |
topic |
Absolute Tracker, EDM baseline, pillars, forced-centring plates, accurate lengths |
url |
https://ojs.cvut.cz/ojs/index.php/gi/article/view/2483 |
work_keys_str_mv |
AT jaroslavbraun absolutebaselinefortestingofelectronicdistancemeters AT filipdvoracek absolutebaselinefortestingofelectronicdistancemeters AT martinstroner absolutebaselinefortestingofelectronicdistancemeters |
_version_ |
1725604238148501504 |