A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
A surgical microscope is large in size, which makes it impossible to be portable. The distance between the surgical microscope and the observation tissue is 15–30 cm, and the adjustment range of the right and left of the camera is a maximum of 30°. Therefore, the surgical microscope generates an att...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-06-01
|
Series: | Diagnostics |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-4418/11/6/1014 |
id |
doaj-b41412a5503d4d1ea1f5d7f68fbdf81c |
---|---|
record_format |
Article |
spelling |
doaj-b41412a5503d4d1ea1f5d7f68fbdf81c2021-06-30T23:03:02ZengMDPI AGDiagnostics2075-44182021-06-01111014101410.3390/diagnostics11061014A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic AcidKicheol Yoon0Kwanggi Kim1Seunghoon Lee2Department of Biomedical Engineering, College of Medicine, Gachon University, 38-13, Dokjom-ro 3, Namdong-gu, Incheon 21565, KoreaDepartment of Biomedical Engineering, College of Medicine, Gachon University, 38-13, Dokjom-ro 3, Namdong-gu, Incheon 21565, KoreaDepartment of Neurosurgery, Daejeon Eulji Medical Center (Eulji University Hospital), Dunsanseo-ro, Seo-gu, Daejeon 35233, KoreaA surgical microscope is large in size, which makes it impossible to be portable. The distance between the surgical microscope and the observation tissue is 15–30 cm, and the adjustment range of the right and left of the camera is a maximum of 30°. Therefore, the surgical microscope generates an attenuation (above 58%) of irradiation of the optical source owing to the long working distance (WD). Moreover, the observation of tissue is affected because of dazzling by ambient light as the optical source power is strong (55 to 160 mW/cm<sup>2</sup>). Further, observation blind spot phenomena will occur due to the limitations in adjusting the right and left of the camera. Therefore, it is difficult to clearly observe the tumor. To overcome these problems, several studies on the handheld surgical microscope have been reported. In this study, a compact pen-type probe with a portable surgical microscope is presented. The proposed surgical microscope comprises a small and portable pen-type probe that can adjust the WD between the probe and the observed tissue. In addition, it allows the adjustment of the viewing angle and fluorescence brightness. The proposed probe has no blind spots or optical density loss.https://www.mdpi.com/2075-4418/11/6/1014fluorescence microscopyfluorescence emissionmalignant tumordiagnosisanimal experiment |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Kicheol Yoon Kwanggi Kim Seunghoon Lee |
spellingShingle |
Kicheol Yoon Kwanggi Kim Seunghoon Lee A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid Diagnostics fluorescence microscopy fluorescence emission malignant tumor diagnosis animal experiment |
author_facet |
Kicheol Yoon Kwanggi Kim Seunghoon Lee |
author_sort |
Kicheol Yoon |
title |
A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid |
title_short |
A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid |
title_full |
A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid |
title_fullStr |
A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid |
title_full_unstemmed |
A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid |
title_sort |
surgical pen-type probe design for real-time optical diagnosis of tumor status using 5-aminolevulinic acid |
publisher |
MDPI AG |
series |
Diagnostics |
issn |
2075-4418 |
publishDate |
2021-06-01 |
description |
A surgical microscope is large in size, which makes it impossible to be portable. The distance between the surgical microscope and the observation tissue is 15–30 cm, and the adjustment range of the right and left of the camera is a maximum of 30°. Therefore, the surgical microscope generates an attenuation (above 58%) of irradiation of the optical source owing to the long working distance (WD). Moreover, the observation of tissue is affected because of dazzling by ambient light as the optical source power is strong (55 to 160 mW/cm<sup>2</sup>). Further, observation blind spot phenomena will occur due to the limitations in adjusting the right and left of the camera. Therefore, it is difficult to clearly observe the tumor. To overcome these problems, several studies on the handheld surgical microscope have been reported. In this study, a compact pen-type probe with a portable surgical microscope is presented. The proposed surgical microscope comprises a small and portable pen-type probe that can adjust the WD between the probe and the observed tissue. In addition, it allows the adjustment of the viewing angle and fluorescence brightness. The proposed probe has no blind spots or optical density loss. |
topic |
fluorescence microscopy fluorescence emission malignant tumor diagnosis animal experiment |
url |
https://www.mdpi.com/2075-4418/11/6/1014 |
work_keys_str_mv |
AT kicheolyoon asurgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid AT kwanggikim asurgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid AT seunghoonlee asurgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid AT kicheolyoon surgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid AT kwanggikim surgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid AT seunghoonlee surgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid |
_version_ |
1721352380098805760 |