SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS
This paper presents a simple embodiment of the system that can be used for the primary stability analysis of the cemented hip prosthesis. The proposed variant is based on experimental test stand for hip prostheses (in terms of tribology) found in Biomechatronics Lab of the Product Design and Environ...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Editura Universităţii din Oradea
2014-11-01
|
Series: | Annals of the Oradea University: Fascicle Management and Technological Engineering |
Subjects: | |
Online Access: | http://imtuoradea.ro/auo.fmte/files-2014-v3/Druga Corneliu-SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS.pdf |
id |
doaj-b35716ead2944d05bd253fe8bab0958d |
---|---|
record_format |
Article |
spelling |
doaj-b35716ead2944d05bd253fe8bab0958d2020-11-24T22:20:58ZengEditura Universităţii din OradeaAnnals of the Oradea University: Fascicle Management and Technological Engineering1583-06911583-06912014-11-01XXIII (XIII)10.AUOFMTE.2014-3.30503050SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESISCorneliu DrugaThis paper presents a simple embodiment of the system that can be used for the primary stability analysis of the cemented hip prosthesis. The proposed variant is based on experimental test stand for hip prostheses (in terms of tribology) found in Biomechatronics Lab of the Product Design and Environment Faculty. For this study three aspects are important: counting the number of cycles that it performs cemented hip prosthesis and the time when the first microdisplacements (in the bone-cement-prosthesis interface) appear and micro-displacement amplitude.http://imtuoradea.ro/auo.fmte/files-2014-v3/Druga Corneliu-SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS.pdfhipprosthesisprimarystabilityinvitroacryliccement. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Corneliu Druga |
spellingShingle |
Corneliu Druga SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS Annals of the Oradea University: Fascicle Management and Technological Engineering hipprosthesis primarystability invitro acryliccement. |
author_facet |
Corneliu Druga |
author_sort |
Corneliu Druga |
title |
SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS |
title_short |
SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS |
title_full |
SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS |
title_fullStr |
SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS |
title_full_unstemmed |
SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS |
title_sort |
system for in vitro primary stability analyzis of cemented hip prosthesis |
publisher |
Editura Universităţii din Oradea |
series |
Annals of the Oradea University: Fascicle Management and Technological Engineering |
issn |
1583-0691 1583-0691 |
publishDate |
2014-11-01 |
description |
This paper presents a simple embodiment of the
system that can be used for the primary stability analysis of the
cemented hip prosthesis. The proposed variant is based on
experimental test stand for hip prostheses (in terms of
tribology) found in Biomechatronics Lab of the Product Design
and Environment Faculty. For this study three aspects are
important: counting the number of cycles that it performs
cemented hip prosthesis and the time when the first microdisplacements
(in the bone-cement-prosthesis interface) appear
and micro-displacement amplitude. |
topic |
hipprosthesis primarystability invitro acryliccement. |
url |
http://imtuoradea.ro/auo.fmte/files-2014-v3/Druga Corneliu-SYSTEM FOR IN VITRO PRIMARY STABILITY ANALYZIS OF CEMENTED HIP PROSTHESIS.pdf |
work_keys_str_mv |
AT corneliudruga systemforinvitroprimarystabilityanalyzisofcementedhipprosthesis |
_version_ |
1725772973279805440 |