Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients

Background: Several alternative airway tools have now become primary devices for endotracheal intubation in obese patients.  Since there were no guidelines to suggest which patient characteristics may be best suited for alternative techniques, we conducted this study to identify which airway bedside...

Full description

Bibliographic Details
Main Author: Arunotai Siriussawakul
Format: Article
Language:English
Published: Mahidol University 2014-11-01
Series:Siriraj Medical Journal
Online Access:https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55312
id doaj-b32b3ba96e004df2821631d49ea827fd
record_format Article
spelling doaj-b32b3ba96e004df2821631d49ea827fd2021-08-13T09:55:10ZengMahidol UniversitySiriraj Medical Journal2228-80822014-11-01666Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese PatientsArunotai Siriussawakul0Health Development Program, Faculty of Medicine, Chulalongkorn University, Bangkok 10330 and Department of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand.Background: Several alternative airway tools have now become primary devices for endotracheal intubation in obese patients.  Since there were no guidelines to suggest which patient characteristics may be best suited for alternative techniques, we conducted this study to identify which airway bedside tests could predict the occurrence of troublesome intubation while performing conventional endotracheal intubation in obese Thai patients. Methods: This cohort study was conducted in 200 obese patients who were expected to not use alternative tools for first-line management in a tertiary care university hospital. Troublesome intubation was defined using an intubation difficulty scale (IDS) score > 0.  An IDS value of 0 means ideal intubation, i.e., one performed without effort, on the first attempt, practiced by one operator, using one technique, with no impediment of the tube passage. Eleven types of preoperative airway assessment – including malformation of central teeth in the upper jaw, a modified Mallampati test, an upper-lip bite test, the range of motion of the neck (flexion and extension), the inter-incisor gap, the hyomental distance, the thyromental distance, the sternomental distance, the neck circumference, and the length of the neck – were examined in all patients. Results: The inter-observer reliability of raters was > 0.7 before initiation of the study. Overall, 52.5% of patients experienced troublesome intubation during conventional endotracheal intubation.  According to a multivariate analysis, the independent risk factors were a modified Mallampati test, the neck circumference, and the inter-incisor gap. Conclusion: Based on our findings, alternative airway tools should be the first line of airway management in the case of patients with a high modified Mallampati test, a large neck circumference, and a short inter-incisor gap. Keywords: Difficult intubation, prediction, airway assessment, obesityhttps://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55312
collection DOAJ
language English
format Article
sources DOAJ
author Arunotai Siriussawakul
spellingShingle Arunotai Siriussawakul
Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
Siriraj Medical Journal
author_facet Arunotai Siriussawakul
author_sort Arunotai Siriussawakul
title Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
title_short Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
title_full Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
title_fullStr Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
title_full_unstemmed Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
title_sort modified mallampati test, neck circumference and short inter-incisor gap are risk factors for troublesome intubation in thai obese patients
publisher Mahidol University
series Siriraj Medical Journal
issn 2228-8082
publishDate 2014-11-01
description Background: Several alternative airway tools have now become primary devices for endotracheal intubation in obese patients.  Since there were no guidelines to suggest which patient characteristics may be best suited for alternative techniques, we conducted this study to identify which airway bedside tests could predict the occurrence of troublesome intubation while performing conventional endotracheal intubation in obese Thai patients. Methods: This cohort study was conducted in 200 obese patients who were expected to not use alternative tools for first-line management in a tertiary care university hospital. Troublesome intubation was defined using an intubation difficulty scale (IDS) score > 0.  An IDS value of 0 means ideal intubation, i.e., one performed without effort, on the first attempt, practiced by one operator, using one technique, with no impediment of the tube passage. Eleven types of preoperative airway assessment – including malformation of central teeth in the upper jaw, a modified Mallampati test, an upper-lip bite test, the range of motion of the neck (flexion and extension), the inter-incisor gap, the hyomental distance, the thyromental distance, the sternomental distance, the neck circumference, and the length of the neck – were examined in all patients. Results: The inter-observer reliability of raters was > 0.7 before initiation of the study. Overall, 52.5% of patients experienced troublesome intubation during conventional endotracheal intubation.  According to a multivariate analysis, the independent risk factors were a modified Mallampati test, the neck circumference, and the inter-incisor gap. Conclusion: Based on our findings, alternative airway tools should be the first line of airway management in the case of patients with a high modified Mallampati test, a large neck circumference, and a short inter-incisor gap. Keywords: Difficult intubation, prediction, airway assessment, obesity
url https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55312
work_keys_str_mv AT arunotaisiriussawakul modifiedmallampatitestneckcircumferenceandshortinterincisorgapareriskfactorsfortroublesomeintubationinthaiobesepatients
_version_ 1721208781623263232