Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients
Background: Several alternative airway tools have now become primary devices for endotracheal intubation in obese patients. Since there were no guidelines to suggest which patient characteristics may be best suited for alternative techniques, we conducted this study to identify which airway bedside...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Mahidol University
2014-11-01
|
Series: | Siriraj Medical Journal |
Online Access: | https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55312 |
id |
doaj-b32b3ba96e004df2821631d49ea827fd |
---|---|
record_format |
Article |
spelling |
doaj-b32b3ba96e004df2821631d49ea827fd2021-08-13T09:55:10ZengMahidol UniversitySiriraj Medical Journal2228-80822014-11-01666Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese PatientsArunotai Siriussawakul0Health Development Program, Faculty of Medicine, Chulalongkorn University, Bangkok 10330 and Department of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand.Background: Several alternative airway tools have now become primary devices for endotracheal intubation in obese patients. Since there were no guidelines to suggest which patient characteristics may be best suited for alternative techniques, we conducted this study to identify which airway bedside tests could predict the occurrence of troublesome intubation while performing conventional endotracheal intubation in obese Thai patients. Methods: This cohort study was conducted in 200 obese patients who were expected to not use alternative tools for first-line management in a tertiary care university hospital. Troublesome intubation was defined using an intubation difficulty scale (IDS) score > 0. An IDS value of 0 means ideal intubation, i.e., one performed without effort, on the first attempt, practiced by one operator, using one technique, with no impediment of the tube passage. Eleven types of preoperative airway assessment – including malformation of central teeth in the upper jaw, a modified Mallampati test, an upper-lip bite test, the range of motion of the neck (flexion and extension), the inter-incisor gap, the hyomental distance, the thyromental distance, the sternomental distance, the neck circumference, and the length of the neck – were examined in all patients. Results: The inter-observer reliability of raters was > 0.7 before initiation of the study. Overall, 52.5% of patients experienced troublesome intubation during conventional endotracheal intubation. According to a multivariate analysis, the independent risk factors were a modified Mallampati test, the neck circumference, and the inter-incisor gap. Conclusion: Based on our findings, alternative airway tools should be the first line of airway management in the case of patients with a high modified Mallampati test, a large neck circumference, and a short inter-incisor gap. Keywords: Difficult intubation, prediction, airway assessment, obesityhttps://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/55312 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Arunotai Siriussawakul |
spellingShingle |
Arunotai Siriussawakul Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients Siriraj Medical Journal |
author_facet |
Arunotai Siriussawakul |
author_sort |
Arunotai Siriussawakul |
title |
Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients |
title_short |
Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients |
title_full |
Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients |
title_fullStr |
Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients |
title_full_unstemmed |
Modified Mallampati Test, Neck Circumference and Short Inter-Incisor Gap Are Risk Factors for Troublesome Intubation in Thai Obese Patients |
title_sort |
modified mallampati test, neck circumference and short inter-incisor gap are risk factors for troublesome intubation in thai obese patients |
publisher |
Mahidol University |
series |
Siriraj Medical Journal |
issn |
2228-8082 |
publishDate |
2014-11-01 |
description |
Background: Several alternative airway tools have now become primary devices for endotracheal intubation in obese patients. Since there were no guidelines to suggest which patient characteristics may be best suited for alternative techniques, we conducted this study to identify which airway bedside tests could predict the occurrence of troublesome intubation while performing conventional endotracheal intubation in obese Thai patients.
Methods: This cohort study was conducted in 200 obese patients who were expected to not use alternative tools for first-line management in a tertiary care university hospital. Troublesome intubation was defined using an intubation difficulty scale (IDS) score > 0. An IDS value of 0 means ideal intubation, i.e., one performed without effort, on the first attempt, practiced by one operator, using one technique, with no impediment of the tube passage. Eleven types of preoperative airway assessment – including malformation of central teeth in the upper jaw, a modified Mallampati test, an upper-lip bite test, the range of motion of the neck (flexion and extension), the inter-incisor gap, the hyomental distance, the thyromental distance, the sternomental distance, the neck circumference, and the length of the neck – were examined in all patients.
Results: The inter-observer reliability of raters was > 0.7 before initiation of the study. Overall, 52.5% of patients experienced troublesome intubation during conventional endotracheal intubation. According to a multivariate analysis, the independent risk factors were a modified Mallampati test, the neck circumference, and the inter-incisor gap.
Conclusion: Based on our findings, alternative airway tools should be the first line of airway management in the case of patients with a high modified Mallampati test, a large neck circumference, and a short inter-incisor gap.