Backup Alternatives for 110 kV Lines
The paper describes backup alternatives for 110 kV lines. Line backup is one of input parameters used to optimise the renovation of 110 kV lines. The optimisation is based on the principle of reliability centred maintenance (RCM) which depends on the technical condition and importance of a particula...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
VSB-Technical University of Ostrava
2013-01-01
|
Series: | Advances in Electrical and Electronic Engineering |
Subjects: | |
Online Access: | http://advances.utc.sk/index.php/AEEE/article/view/796 |
id |
doaj-b31a3fd47a3c438da920d1c027830e7f |
---|---|
record_format |
Article |
spelling |
doaj-b31a3fd47a3c438da920d1c027830e7f2021-10-11T08:03:02ZengVSB-Technical University of OstravaAdvances in Electrical and Electronic Engineering1336-13761804-31192013-01-0111316917310.15598/aeee.v11i3.796587Backup Alternatives for 110 kV LinesVit Houdek0Stanislav Rusek1Radomir Gono2VSB - Technical University of OstravaVSB - Technical University of OstravaVSB - Technical University of OstravaThe paper describes backup alternatives for 110 kV lines. Line backup is one of input parameters used to optimise the renovation of 110 kV lines. The optimisation is based on the principle of reliability centred maintenance (RCM) which depends on the technical condition and importance of a particular element. The paper starts with illustrating the method of reliability schemes. This method enables the evaluation of failure-free operation probability. The probability of a failure-free operation can be estimated for all backup types of 110 kV lines existing in the distribution network. To compare different backup alternatives, type lines were selected and calculated with. The results of the method helped estimate the effects of a line failure for a particular distribution district.http://advances.utc.sk/index.php/AEEE/article/view/796backupeffect of failuremainetancercmreliability. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Vit Houdek Stanislav Rusek Radomir Gono |
spellingShingle |
Vit Houdek Stanislav Rusek Radomir Gono Backup Alternatives for 110 kV Lines Advances in Electrical and Electronic Engineering backup effect of failure mainetance rcm reliability. |
author_facet |
Vit Houdek Stanislav Rusek Radomir Gono |
author_sort |
Vit Houdek |
title |
Backup Alternatives for 110 kV Lines |
title_short |
Backup Alternatives for 110 kV Lines |
title_full |
Backup Alternatives for 110 kV Lines |
title_fullStr |
Backup Alternatives for 110 kV Lines |
title_full_unstemmed |
Backup Alternatives for 110 kV Lines |
title_sort |
backup alternatives for 110 kv lines |
publisher |
VSB-Technical University of Ostrava |
series |
Advances in Electrical and Electronic Engineering |
issn |
1336-1376 1804-3119 |
publishDate |
2013-01-01 |
description |
The paper describes backup alternatives for 110 kV lines. Line backup is one of input parameters used to optimise the renovation of 110 kV lines. The optimisation is based on the principle of reliability centred maintenance (RCM) which depends on the technical condition and importance of a particular element. The paper starts with illustrating the method of reliability schemes. This method enables the evaluation of failure-free operation probability. The probability of a failure-free operation can be estimated for all backup types of 110 kV lines existing in the distribution network. To compare different backup alternatives, type lines were selected and calculated with. The results of the method helped estimate the effects of a line failure for a particular distribution district. |
topic |
backup effect of failure mainetance rcm reliability. |
url |
http://advances.utc.sk/index.php/AEEE/article/view/796 |
work_keys_str_mv |
AT vithoudek backupalternativesfor110kvlines AT stanislavrusek backupalternativesfor110kvlines AT radomirgono backupalternativesfor110kvlines |
_version_ |
1716828125969514496 |