The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study

Adhesion of dental materials to the dental hard tissue is dependent on a number of factors relating both to the material used and the type of approach to dental substrate. The purpose of this study was to analyze the size of the hybrid layer (HL) in evaluated sealed oclussal surfaces by scanning ele...

Full description

Bibliographic Details
Main Authors: Catalina Iulia Saveanu, Anca Todirascu, Irina Maftei, Ioan Danila
Format: Article
Language:English
Published: Romanian Society of Oral Rehabilitation 2012-01-01
Series:Romanian Journal of Oral Rehabilitation
Subjects:
Online Access:http://www.rjor.ro/the-influence-of-the-etching-time-on-the-enamel-hybridization-in-preventive-sealing-in-vitro-study/?lang=ro
id doaj-b2b7ccebbd8949008edac17396a925de
record_format Article
spelling doaj-b2b7ccebbd8949008edac17396a925de2020-11-24T23:52:01ZengRomanian Society of Oral RehabilitationRomanian Journal of Oral Rehabilitation2066-70002601-46612012-01-01348489The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro StudyCatalina Iulia Saveanu0Anca Todirascu1Irina Maftei2Ioan Danila3Assistant Professor, PhD - Department of Oro-Dental Prevention, Faculty of Dentistry, "Gr. T. Popa" University of Medicine and Pharmacy, Iasi, RomaniaStudent - Faculty of Dentistry, "Gr. T. Popa" University of Medicine and Pharmacy, Iasi, RomaniaPhD - Department of Oro-Dental Prevention, Faculty of Dentistry, "Gr. T. Popa" University of Medicine and Pharmacy, Iasi, RomaniaProfessor, PhD - Department of Oro-Dental Prevention, Faculty of Dentistry, "Gr. T. Popa" University of Medicine and Pharmacy, Iasi, RomaniaAdhesion of dental materials to the dental hard tissue is dependent on a number of factors relating both to the material used and the type of approach to dental substrate. The purpose of this study was to analyze the size of the hybrid layer (HL) in evaluated sealed oclussal surfaces by scanning electron microscopy (SEM). Method: The study was realized in vitro on a sample of 16 human teeth premolars and molars extracted for orthodontic or periodontal reasons. Permission was obtained from an institutional ethical committee of “Gr. T. Popa” University of Medicine and Pharmacy, Iasi and the subjects gave written, informed consent. The teeth were randomly divided into two equal groups (Gr1=etching time 20 seconds and GR2=etching time 60 seconds). The teeth were restored using 3M™ Schotchbond Etch, Single Bond Dental Adhesive System 3MTM, composite resin Concise (3MESPE). The materials were photo activated with halogen source (3M), stored (48h), cut lengthwise (diamond), polished, conditioned (H3PO4-37%-5s) analysed by SEM (TESLA, BS 340), SPSS14.00 statistically analysed (ANOVA, p≤0.05). Results: Analysis of the HL has highlighted differences between groups only in the enamel p=.000 average size HL being Gr.1:17.76 (±6.7)μm;Gr.2:6.36(±2.8)μm. Conclusions: The thickness of hybrid layer related directly proportional with etching time, after 60 second the hybrid layer had a thickness of about three times higher than in the case for 20 seconds demineralization. Key words: resin composite, hybrid layer, enamel etchhttp://www.rjor.ro/the-influence-of-the-etching-time-on-the-enamel-hybridization-in-preventive-sealing-in-vitro-study/?lang=roresin compositehybrid layerenamel etch
collection DOAJ
language English
format Article
sources DOAJ
author Catalina Iulia Saveanu
Anca Todirascu
Irina Maftei
Ioan Danila
spellingShingle Catalina Iulia Saveanu
Anca Todirascu
Irina Maftei
Ioan Danila
The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study
Romanian Journal of Oral Rehabilitation
resin composite
hybrid layer
enamel etch
author_facet Catalina Iulia Saveanu
Anca Todirascu
Irina Maftei
Ioan Danila
author_sort Catalina Iulia Saveanu
title The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study
title_short The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study
title_full The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study
title_fullStr The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study
title_full_unstemmed The Influence Of The Etching Time On The Enamel Hybridization In Preventive Sealing. In Vitro Study
title_sort influence of the etching time on the enamel hybridization in preventive sealing. in vitro study
publisher Romanian Society of Oral Rehabilitation
series Romanian Journal of Oral Rehabilitation
issn 2066-7000
2601-4661
publishDate 2012-01-01
description Adhesion of dental materials to the dental hard tissue is dependent on a number of factors relating both to the material used and the type of approach to dental substrate. The purpose of this study was to analyze the size of the hybrid layer (HL) in evaluated sealed oclussal surfaces by scanning electron microscopy (SEM). Method: The study was realized in vitro on a sample of 16 human teeth premolars and molars extracted for orthodontic or periodontal reasons. Permission was obtained from an institutional ethical committee of “Gr. T. Popa” University of Medicine and Pharmacy, Iasi and the subjects gave written, informed consent. The teeth were randomly divided into two equal groups (Gr1=etching time 20 seconds and GR2=etching time 60 seconds). The teeth were restored using 3M™ Schotchbond Etch, Single Bond Dental Adhesive System 3MTM, composite resin Concise (3MESPE). The materials were photo activated with halogen source (3M), stored (48h), cut lengthwise (diamond), polished, conditioned (H3PO4-37%-5s) analysed by SEM (TESLA, BS 340), SPSS14.00 statistically analysed (ANOVA, p≤0.05). Results: Analysis of the HL has highlighted differences between groups only in the enamel p=.000 average size HL being Gr.1:17.76 (±6.7)μm;Gr.2:6.36(±2.8)μm. Conclusions: The thickness of hybrid layer related directly proportional with etching time, after 60 second the hybrid layer had a thickness of about three times higher than in the case for 20 seconds demineralization. Key words: resin composite, hybrid layer, enamel etch
topic resin composite
hybrid layer
enamel etch
url http://www.rjor.ro/the-influence-of-the-etching-time-on-the-enamel-hybridization-in-preventive-sealing-in-vitro-study/?lang=ro
work_keys_str_mv AT catalinaiuliasaveanu theinfluenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT ancatodirascu theinfluenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT irinamaftei theinfluenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT ioandanila theinfluenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT catalinaiuliasaveanu influenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT ancatodirascu influenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT irinamaftei influenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
AT ioandanila influenceoftheetchingtimeontheenamelhybridizationinpreventivesealinginvitrostudy
_version_ 1725475090849595392