Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012

Nitrous Oxide gas can affect the patient and also cause chronic complications in operating room staff in the short term. In the current survey, we measured the Nitrous Oxide gas levels in the operating room of the educational hospitals of the Ahvaz Jundishapur Medical University. 576 samples wer...

Full description

Bibliographic Details
Main Authors: Masoumeh Albooghobeish, Dr. Abdolkazem nesisi, Mostafa Fattahi, Shahnam Sedigh Marofi
Format: Article
Language:English
Published: Iranian Journal of Health, Safety and Environment 2014-08-01
Series:Iranian Journal of Health, Safety and Environment
Online Access:http://www.ijhse.ir/index.php/IJHSE/article/view/44
id doaj-b23c3f54906748fca4f8b61b83fdfaf2
record_format Article
spelling doaj-b23c3f54906748fca4f8b61b83fdfaf22020-11-24T23:22:53ZengIranian Journal of Health, Safety and EnvironmentIranian Journal of Health, Safety and Environment2345-32062345-55352014-08-011313814427Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012Masoumeh Albooghobeish0Dr. Abdolkazem nesisi1Mostafa Fattahi2Shahnam Sedigh Marofi3Anesthesiology Department, Ahwaz Jondishapour University of Medical Sciences, Ahwaz , Iran.Environmental Health Engineering Department, Environmental Technologies Research Centre, Ahwaz Jundishapour University of Medical Sciences, Ahwaz, IranAnesthesiology Department, Ahwaz Jondishapour University of Medical Sciences, Ahwaz , Iran.Anesthesiology Department, Iran University of Medical Sciences, Tehran , IranNitrous Oxide gas can affect the patient and also cause chronic complications in operating room staff in the short term. In the current survey, we measured the Nitrous Oxide gas levels in the operating room of the educational hospitals of the Ahvaz Jundishapur Medical University. 576 samples were taken from 32 operating rooms through 4 months. Sampling was done in 3 different working times (8:30-9:00, 10:30-11, 12:30-13:00) from 6 different sites in the operating room. Portable infrared spectrophotometer was used for measuring the concentration of nitrous oxide. The apparatus was calibrated by Nitrous Oxide gas capsule before each reading. Variance analysis was used to compare the means of Nitrous Oxide levels between places of sampling in the operating rooms. There was a significant difference between these amounts (p≤0.00). Then LSD analysis was used to locate the variation factor. The exhaust of the anesthesia machine was the most noted place (p≤0.0001) and the other places did not show significant differences. There was a significant difference between measurements recorded when the air-conditioning system was on or off and if there was an air-conditioning system or not. These differences were observed at all the measurement times. According to the results from the current study, levels of Nitrous Oxide in operating rooms were higher than that recommended by international organizations (25 ppm) and it appears that exposure to this amount of gas could be potentially harmful for staff. It is recommended to take special safety measures and prevent the gas to be increased in the operating room using air conditioning and proper ventilation of the room.http://www.ijhse.ir/index.php/IJHSE/article/view/44
collection DOAJ
language English
format Article
sources DOAJ
author Masoumeh Albooghobeish
Dr. Abdolkazem nesisi
Mostafa Fattahi
Shahnam Sedigh Marofi
spellingShingle Masoumeh Albooghobeish
Dr. Abdolkazem nesisi
Mostafa Fattahi
Shahnam Sedigh Marofi
Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012
Iranian Journal of Health, Safety and Environment
author_facet Masoumeh Albooghobeish
Dr. Abdolkazem nesisi
Mostafa Fattahi
Shahnam Sedigh Marofi
author_sort Masoumeh Albooghobeish
title Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012
title_short Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012
title_full Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012
title_fullStr Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012
title_full_unstemmed Measurement of Nitrous Oxide gas pollution in operating rooms of educational hospitals of Ahvaz Jundishapur University in the year 2012
title_sort measurement of nitrous oxide gas pollution in operating rooms of educational hospitals of ahvaz jundishapur university in the year 2012
publisher Iranian Journal of Health, Safety and Environment
series Iranian Journal of Health, Safety and Environment
issn 2345-3206
2345-5535
publishDate 2014-08-01
description Nitrous Oxide gas can affect the patient and also cause chronic complications in operating room staff in the short term. In the current survey, we measured the Nitrous Oxide gas levels in the operating room of the educational hospitals of the Ahvaz Jundishapur Medical University. 576 samples were taken from 32 operating rooms through 4 months. Sampling was done in 3 different working times (8:30-9:00, 10:30-11, 12:30-13:00) from 6 different sites in the operating room. Portable infrared spectrophotometer was used for measuring the concentration of nitrous oxide. The apparatus was calibrated by Nitrous Oxide gas capsule before each reading. Variance analysis was used to compare the means of Nitrous Oxide levels between places of sampling in the operating rooms. There was a significant difference between these amounts (p≤0.00). Then LSD analysis was used to locate the variation factor. The exhaust of the anesthesia machine was the most noted place (p≤0.0001) and the other places did not show significant differences. There was a significant difference between measurements recorded when the air-conditioning system was on or off and if there was an air-conditioning system or not. These differences were observed at all the measurement times. According to the results from the current study, levels of Nitrous Oxide in operating rooms were higher than that recommended by international organizations (25 ppm) and it appears that exposure to this amount of gas could be potentially harmful for staff. It is recommended to take special safety measures and prevent the gas to be increased in the operating room using air conditioning and proper ventilation of the room.
url http://www.ijhse.ir/index.php/IJHSE/article/view/44
work_keys_str_mv AT masoumehalbooghobeish measurementofnitrousoxidegaspollutioninoperatingroomsofeducationalhospitalsofahvazjundishapuruniversityintheyear2012
AT drabdolkazemnesisi measurementofnitrousoxidegaspollutioninoperatingroomsofeducationalhospitalsofahvazjundishapuruniversityintheyear2012
AT mostafafattahi measurementofnitrousoxidegaspollutioninoperatingroomsofeducationalhospitalsofahvazjundishapuruniversityintheyear2012
AT shahnamsedighmarofi measurementofnitrousoxidegaspollutioninoperatingroomsofeducationalhospitalsofahvazjundishapuruniversityintheyear2012
_version_ 1725566451461390336