Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate
A desiccant air handling unit is one of the major types of dehumidification handling systems and requires hot water or hot air to regenerate sorption materials. If solar thermal energy is used as the heat source for regeneration, in general, a backup electrical heater, backup boiler, or combined hea...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-03-01
|
Series: | Sustainability |
Subjects: | |
Online Access: | https://www.mdpi.com/2071-1050/12/5/1921 |
id |
doaj-b13dc6c5e237420b8edd42d284f6ea26 |
---|---|
record_format |
Article |
spelling |
doaj-b13dc6c5e237420b8edd42d284f6ea262020-11-25T03:03:25ZengMDPI AGSustainability2071-10502020-03-01125192110.3390/su12051921su12051921Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid ClimateMakiko Ukai0Masaya Okumiya1Hideki Tanaka2Graduate School of Environmental Studies, Nagoya University, Nagoya 464-8603, JapanGraduate School of Environmental Studies, Nagoya University, Nagoya 464-8603, JapanCampus Planning & Environment Management Office, Nagoya University, Nagoya 464-8603, JapanA desiccant air handling unit is one of the major types of dehumidification handling systems and requires hot water or hot air to regenerate sorption materials. If solar thermal energy is used as the heat source for regeneration, in general, a backup electrical heater, backup boiler, or combined heat and power (CHP) is installed in order to maintain a stable hot water supply. In this study, effective control is proposed for a desiccant air handling system that uses solar thermal energy (flexible control), and its energy performance is compared to that of a traditional control (the fixed control) through a system simulation. The diurnal behavior shows that the system with a fixed control without a backup boiler cannot process the latent load properly (28 GJ of unprocessed latent load for July and August). On the other hand, the system with a flexible control without a backup boiler is able to process required latent heat load. Based on the fact that the fixed control needs a backup boiler to process the latent load, the system with a fixed control with a backup boiler is considered for the energy performance comparison. The simulation results show that the primary energy-based coefficient of performance (hereafter, COP) of the system with a flexible control without a backup boiler reaches 1.56. On the other hand, the primary energy-based COP of the system with a fixed control with a backup boiler reaches only 1.43. This proves that the flexible control contributes to the higher energy performance of the system and maximizes the use of solar thermal energy more than the fixed control.https://www.mdpi.com/2071-1050/12/5/1921desiccant air handling unitperformance evaluationflexible control |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Makiko Ukai Masaya Okumiya Hideki Tanaka |
spellingShingle |
Makiko Ukai Masaya Okumiya Hideki Tanaka Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate Sustainability desiccant air handling unit performance evaluation flexible control |
author_facet |
Makiko Ukai Masaya Okumiya Hideki Tanaka |
author_sort |
Makiko Ukai |
title |
Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate |
title_short |
Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate |
title_full |
Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate |
title_fullStr |
Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate |
title_full_unstemmed |
Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate |
title_sort |
energy performance evaluation of a desiccant air handling system to maximize solar thermal energy use in a hot and humid climate |
publisher |
MDPI AG |
series |
Sustainability |
issn |
2071-1050 |
publishDate |
2020-03-01 |
description |
A desiccant air handling unit is one of the major types of dehumidification handling systems and requires hot water or hot air to regenerate sorption materials. If solar thermal energy is used as the heat source for regeneration, in general, a backup electrical heater, backup boiler, or combined heat and power (CHP) is installed in order to maintain a stable hot water supply. In this study, effective control is proposed for a desiccant air handling system that uses solar thermal energy (flexible control), and its energy performance is compared to that of a traditional control (the fixed control) through a system simulation. The diurnal behavior shows that the system with a fixed control without a backup boiler cannot process the latent load properly (28 GJ of unprocessed latent load for July and August). On the other hand, the system with a flexible control without a backup boiler is able to process required latent heat load. Based on the fact that the fixed control needs a backup boiler to process the latent load, the system with a fixed control with a backup boiler is considered for the energy performance comparison. The simulation results show that the primary energy-based coefficient of performance (hereafter, COP) of the system with a flexible control without a backup boiler reaches 1.56. On the other hand, the primary energy-based COP of the system with a fixed control with a backup boiler reaches only 1.43. This proves that the flexible control contributes to the higher energy performance of the system and maximizes the use of solar thermal energy more than the fixed control. |
topic |
desiccant air handling unit performance evaluation flexible control |
url |
https://www.mdpi.com/2071-1050/12/5/1921 |
work_keys_str_mv |
AT makikoukai energyperformanceevaluationofadesiccantairhandlingsystemtomaximizesolarthermalenergyuseinahotandhumidclimate AT masayaokumiya energyperformanceevaluationofadesiccantairhandlingsystemtomaximizesolarthermalenergyuseinahotandhumidclimate AT hidekitanaka energyperformanceevaluationofadesiccantairhandlingsystemtomaximizesolarthermalenergyuseinahotandhumidclimate |
_version_ |