Determination of HIV-1 viral load on dried blood spot specimens

Dried blood spot specimens on filter paper were evaluated to determine the viral load of the human immunodeficiency virus type 1 (HIV-1), through the Cobas(r)Ampliprep/Cobas(r)Taqman(r) HIV-1 test. RNA levels were quantified in pairs of plasma and dry blood spot specimens on filter paper from person...

Full description

Bibliographic Details
Main Authors: Nancy M Ruiz, María T Pérez, Héctor M Díaz, Maricela Izquierdo, Madeline Blanco, Liuber Y Machado, Eladio Silva
Format: Article
Language:English
Published: Elfos Scientiae
Series:Biotecnología Aplicada
Subjects:
arn
Online Access:http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1027-28522014000200006&lng=en&tlng=en
id doaj-b00f9d2f3a6b42c3a5ef56e2346ffe07
record_format Article
spelling doaj-b00f9d2f3a6b42c3a5ef56e2346ffe072020-11-25T03:18:53ZengElfos ScientiaeBiotecnología Aplicada1027-2852312146149S1027-28522014000200006Determination of HIV-1 viral load on dried blood spot specimensNancy M Ruiz0María T Pérez1Héctor M Díaz2Maricela Izquierdo3Madeline Blanco4Liuber Y Machado5Eladio Silva6Laboratorio de Investigaciones del Sida, LisidaLisidaLisidaLisidaLaboratorio de Investigaciones del Sida, LisidaLaboratorio de Investigaciones del Sida, LisidaLisidaDried blood spot specimens on filter paper were evaluated to determine the viral load of the human immunodeficiency virus type 1 (HIV-1), through the Cobas(r)Ampliprep/Cobas(r)Taqman(r) HIV-1 test. RNA levels were quantified in pairs of plasma and dry blood spot specimens on filter paper from persons infected with HIV-1. The Pearson linear correlation coefficient was calculated as well as the agreement by the Bland-Altman method. Studies on precision, linearity and analytical sensitivity of the assay were also carried out. The linear regression model was used to predict the value of the viral load in the plasma. There was a high correlation in viral load measurements in the plasma and dried blood spot specimens, in 39 out of the 43 sample pairs studied (r = 0.964, p < 0.0001). Detection rate was 90.7 % and the test behaved linearly between 134 and 420 000 copies/mL of viral RNA, showing good precision. No statistically significant differences were observed between the means of the true and predicted values of viral load in the plasma, with a 95 % confidence level. These results support the use of dried blood spots on filter paper for viral load determination with the Cobas(r)Ampliprep/Cobas(r)Taqman(r) HIV-1 Test. Authors recommend the validation of the model proposed with a larger number of samples.http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1027-28522014000200006&lng=en&tlng=envih-1arncarga viralsangre seca en papel de filtrocap/ctm hiv-1 test
collection DOAJ
language English
format Article
sources DOAJ
author Nancy M Ruiz
María T Pérez
Héctor M Díaz
Maricela Izquierdo
Madeline Blanco
Liuber Y Machado
Eladio Silva
spellingShingle Nancy M Ruiz
María T Pérez
Héctor M Díaz
Maricela Izquierdo
Madeline Blanco
Liuber Y Machado
Eladio Silva
Determination of HIV-1 viral load on dried blood spot specimens
Biotecnología Aplicada
vih-1
arn
carga viral
sangre seca en papel de filtro
cap/ctm hiv-1 test
author_facet Nancy M Ruiz
María T Pérez
Héctor M Díaz
Maricela Izquierdo
Madeline Blanco
Liuber Y Machado
Eladio Silva
author_sort Nancy M Ruiz
title Determination of HIV-1 viral load on dried blood spot specimens
title_short Determination of HIV-1 viral load on dried blood spot specimens
title_full Determination of HIV-1 viral load on dried blood spot specimens
title_fullStr Determination of HIV-1 viral load on dried blood spot specimens
title_full_unstemmed Determination of HIV-1 viral load on dried blood spot specimens
title_sort determination of hiv-1 viral load on dried blood spot specimens
publisher Elfos Scientiae
series Biotecnología Aplicada
issn 1027-2852
description Dried blood spot specimens on filter paper were evaluated to determine the viral load of the human immunodeficiency virus type 1 (HIV-1), through the Cobas(r)Ampliprep/Cobas(r)Taqman(r) HIV-1 test. RNA levels were quantified in pairs of plasma and dry blood spot specimens on filter paper from persons infected with HIV-1. The Pearson linear correlation coefficient was calculated as well as the agreement by the Bland-Altman method. Studies on precision, linearity and analytical sensitivity of the assay were also carried out. The linear regression model was used to predict the value of the viral load in the plasma. There was a high correlation in viral load measurements in the plasma and dried blood spot specimens, in 39 out of the 43 sample pairs studied (r = 0.964, p < 0.0001). Detection rate was 90.7 % and the test behaved linearly between 134 and 420 000 copies/mL of viral RNA, showing good precision. No statistically significant differences were observed between the means of the true and predicted values of viral load in the plasma, with a 95 % confidence level. These results support the use of dried blood spots on filter paper for viral load determination with the Cobas(r)Ampliprep/Cobas(r)Taqman(r) HIV-1 Test. Authors recommend the validation of the model proposed with a larger number of samples.
topic vih-1
arn
carga viral
sangre seca en papel de filtro
cap/ctm hiv-1 test
url http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1027-28522014000200006&lng=en&tlng=en
work_keys_str_mv AT nancymruiz determinationofhiv1viralloadondriedbloodspotspecimens
AT mariatperez determinationofhiv1viralloadondriedbloodspotspecimens
AT hectormdiaz determinationofhiv1viralloadondriedbloodspotspecimens
AT maricelaizquierdo determinationofhiv1viralloadondriedbloodspotspecimens
AT madelineblanco determinationofhiv1viralloadondriedbloodspotspecimens
AT liuberymachado determinationofhiv1viralloadondriedbloodspotspecimens
AT eladiosilva determinationofhiv1viralloadondriedbloodspotspecimens
_version_ 1724625161958719488