Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer

<p>Abstract</p> <p>Background</p> <p>4-dimensional CT (4DCT) scans are increasingly used to account for mobility during radiotherapy planning. As variations in respiratory patterns can alter observed motion, with consequent changes in the generated target volumes, we ev...

Full description

Bibliographic Details
Main Authors: Cuijpers Johan P, van Sörnsen de Koste John R, Lagerwaard Frank J, van der Geld Ylanga G, Slotman Ben J, Senan Suresh
Format: Article
Language:English
Published: BMC 2006-11-01
Series:Radiation Oncology
Online Access:http://www.ro-journal.com/content/1/1/43
id doaj-af737166a84c4d66b6b93d4fa1f1f632
record_format Article
spelling doaj-af737166a84c4d66b6b93d4fa1f1f6322020-11-25T00:19:18ZengBMCRadiation Oncology1748-717X2006-11-01114310.1186/1748-717X-1-43Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancerCuijpers Johan Pvan Sörnsen de Koste John RLagerwaard Frank Jvan der Geld Ylanga GSlotman Ben JSenan Suresh<p>Abstract</p> <p>Background</p> <p>4-dimensional CT (4DCT) scans are increasingly used to account for mobility during radiotherapy planning. As variations in respiratory patterns can alter observed motion, with consequent changes in the generated target volumes, we evaluated the reproducibility of 4D target volumes generated during repeat uncoached quiet respiration.</p> <p>Methods</p> <p>A retrospective analysis was performed on two successive scans (4DCT1 and 4DCT2) generated at the same scanning session for 26 patients with peripheral lung cancer treated with stereotactic radiotherapy (SRT). The volume and position of planning target volumes (PTV<sub>4DCT1 </sub>and PTV<sub>4DCT2</sub>) contoured on both scans were compared, and a dosimetric analysis performed. A SRT plan optimized for each PTV was sequentially applied to the other PTV, and coverage by the 80% isodose was evaluated. Color intensity projections (CIP) were used to evaluate regions of underdosage.</p> <p>Results</p> <p>No significant volumetric differences were observed between the two PTVs (<it>t</it>-Test p = 0.60). The average displacement of the center of mass between corresponding PTVs was 1.4 ± 1.0 mm, but differences in position were 2.0 mm or greater in 5 cases (19%). Coverage of both PTVs by the 80% prescription isodose exceeded 90% for all but one patient. For the latter, the prescription isodose covered only 82.5% of PTV<sub>4DCT1</sub>. CIP analysis revealed that the region of underdosage was an end-inspiratory position occupied by the tumor for only 10–20% of the respiratory cycle.</p> <p>Conclusion</p> <p>In nearly all patients with stage I lung cancer, the PTV derived from a single uncoached 4DCT achieves dosimetric coverage that is similar to that achieved using two such consecutive scans.</p> http://www.ro-journal.com/content/1/1/43
collection DOAJ
language English
format Article
sources DOAJ
author Cuijpers Johan P
van Sörnsen de Koste John R
Lagerwaard Frank J
van der Geld Ylanga G
Slotman Ben J
Senan Suresh
spellingShingle Cuijpers Johan P
van Sörnsen de Koste John R
Lagerwaard Frank J
van der Geld Ylanga G
Slotman Ben J
Senan Suresh
Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer
Radiation Oncology
author_facet Cuijpers Johan P
van Sörnsen de Koste John R
Lagerwaard Frank J
van der Geld Ylanga G
Slotman Ben J
Senan Suresh
author_sort Cuijpers Johan P
title Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer
title_short Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer
title_full Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer
title_fullStr Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer
title_full_unstemmed Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer
title_sort reproducibility of target volumes generated using uncoached 4-dimensional ct scans for peripheral lung cancer
publisher BMC
series Radiation Oncology
issn 1748-717X
publishDate 2006-11-01
description <p>Abstract</p> <p>Background</p> <p>4-dimensional CT (4DCT) scans are increasingly used to account for mobility during radiotherapy planning. As variations in respiratory patterns can alter observed motion, with consequent changes in the generated target volumes, we evaluated the reproducibility of 4D target volumes generated during repeat uncoached quiet respiration.</p> <p>Methods</p> <p>A retrospective analysis was performed on two successive scans (4DCT1 and 4DCT2) generated at the same scanning session for 26 patients with peripheral lung cancer treated with stereotactic radiotherapy (SRT). The volume and position of planning target volumes (PTV<sub>4DCT1 </sub>and PTV<sub>4DCT2</sub>) contoured on both scans were compared, and a dosimetric analysis performed. A SRT plan optimized for each PTV was sequentially applied to the other PTV, and coverage by the 80% isodose was evaluated. Color intensity projections (CIP) were used to evaluate regions of underdosage.</p> <p>Results</p> <p>No significant volumetric differences were observed between the two PTVs (<it>t</it>-Test p = 0.60). The average displacement of the center of mass between corresponding PTVs was 1.4 ± 1.0 mm, but differences in position were 2.0 mm or greater in 5 cases (19%). Coverage of both PTVs by the 80% prescription isodose exceeded 90% for all but one patient. For the latter, the prescription isodose covered only 82.5% of PTV<sub>4DCT1</sub>. CIP analysis revealed that the region of underdosage was an end-inspiratory position occupied by the tumor for only 10–20% of the respiratory cycle.</p> <p>Conclusion</p> <p>In nearly all patients with stage I lung cancer, the PTV derived from a single uncoached 4DCT achieves dosimetric coverage that is similar to that achieved using two such consecutive scans.</p>
url http://www.ro-journal.com/content/1/1/43
work_keys_str_mv AT cuijpersjohanp reproducibilityoftargetvolumesgeneratedusinguncoached4dimensionalctscansforperipherallungcancer
AT vansornsendekostejohnr reproducibilityoftargetvolumesgeneratedusinguncoached4dimensionalctscansforperipherallungcancer
AT lagerwaardfrankj reproducibilityoftargetvolumesgeneratedusinguncoached4dimensionalctscansforperipherallungcancer
AT vandergeldylangag reproducibilityoftargetvolumesgeneratedusinguncoached4dimensionalctscansforperipherallungcancer
AT slotmanbenj reproducibilityoftargetvolumesgeneratedusinguncoached4dimensionalctscansforperipherallungcancer
AT senansuresh reproducibilityoftargetvolumesgeneratedusinguncoached4dimensionalctscansforperipherallungcancer
_version_ 1725372041216917504