DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
Turbines convert the kinetic energy of ocean currents into electrical energy produced by the sea current electric power plant. This study aims to design a power generator turbine modeling that is carried out using the Computational Fluid Dynamic (CFD) approach by comparing the geometric performance...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
Universitas Mercu Buana
2020-11-01
|
Series: | Jurnal Ilmiah SINERGI |
Subjects: | |
Online Access: | https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8137 |
id |
doaj-af688f7795fe41d4a34a02d9a8b1c871 |
---|---|
record_format |
Article |
spelling |
doaj-af688f7795fe41d4a34a02d9a8b1c8712020-12-23T09:12:39ZindUniversitas Mercu BuanaJurnal Ilmiah SINERGI1410-23312460-12172020-11-01251273210.22441/sinergi.2021.1.0043785DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANTBoris Metheny0Rosyida Permatasari1Muhammad Sjahrul Annas2Department of Mechanical Engineering, Universitas TrisaktiDepartment of Mechanical Engineering, Universitas TrisaktiDepartment of Mechanical Engineering, Universitas TrisaktiTurbines convert the kinetic energy of ocean currents into electrical energy produced by the sea current electric power plant. This study aims to design a power generator turbine modeling that is carried out using the Computational Fluid Dynamic (CFD) approach by comparing the geometric performance based on the angle of attack and the Tip Speed Ratio (TSR) value of the Savonius-Darrieus Turbine. Having done several trials and errors during collecting the data, the value of the TSR 1.427; 2.853; 4.28; 5; and 5.7 is proposed. Here, the NACA 0018 series has been adopted on the current design of Savonius-Darrieus Turbine. The turbine has three blades, length of the span 357 mm, the diameter of turbine 428 mm, and length of the hydrofoil chord 40 mm. Effect of various angle of attacks from 0°up to 10° has been taken into account in the computational to obtain the coefficient power for each variation. The results revealed that the turbine with an angle of attack of 5°and TSR value of 5.0 has higher power coefficient value by 0.469 as compared with its angle of attack of 10°. It should be noted here that the increase of the angle of attack up to 10° resulted in a significant reduction of the power coefficient value of 0.206 as the value of TSR about 4.28. The addition of the Savonius Rotor results in increasing efficiency of the turbine for sea current applications.https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8137angle of attackcfdcoefficient of powersavonius-darrieus turbinetsr |
collection |
DOAJ |
language |
Indonesian |
format |
Article |
sources |
DOAJ |
author |
Boris Metheny Rosyida Permatasari Muhammad Sjahrul Annas |
spellingShingle |
Boris Metheny Rosyida Permatasari Muhammad Sjahrul Annas DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT Jurnal Ilmiah SINERGI angle of attack cfd coefficient of power savonius-darrieus turbine tsr |
author_facet |
Boris Metheny Rosyida Permatasari Muhammad Sjahrul Annas |
author_sort |
Boris Metheny |
title |
DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT |
title_short |
DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT |
title_full |
DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT |
title_fullStr |
DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT |
title_full_unstemmed |
DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT |
title_sort |
design modeling of savonius-darrieus turbine for sea current electric power plant |
publisher |
Universitas Mercu Buana |
series |
Jurnal Ilmiah SINERGI |
issn |
1410-2331 2460-1217 |
publishDate |
2020-11-01 |
description |
Turbines convert the kinetic energy of ocean currents into electrical energy produced by the sea current electric power plant. This study aims to design a power generator turbine modeling that is carried out using the Computational Fluid Dynamic (CFD) approach by comparing the geometric performance based on the angle of attack and the Tip Speed Ratio (TSR) value of the Savonius-Darrieus Turbine. Having done several trials and errors during collecting the data, the value of the TSR 1.427; 2.853; 4.28; 5; and 5.7 is proposed. Here, the NACA 0018 series has been adopted on the current design of Savonius-Darrieus Turbine. The turbine has three blades, length of the span 357 mm, the diameter of turbine 428 mm, and length of the hydrofoil chord 40 mm. Effect of various angle of attacks from 0°up to 10° has been taken into account in the computational to obtain the coefficient power for each variation. The results revealed that the turbine with an angle of attack of 5°and TSR value of 5.0 has higher power coefficient value by 0.469 as compared with its angle of attack of 10°. It should be noted here that the increase of the angle of attack up to 10° resulted in a significant reduction of the power coefficient value of 0.206 as the value of TSR about 4.28. The addition of the Savonius Rotor results in increasing efficiency of the turbine for sea current applications. |
topic |
angle of attack cfd coefficient of power savonius-darrieus turbine tsr |
url |
https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8137 |
work_keys_str_mv |
AT borismetheny designmodelingofsavoniusdarrieusturbineforseacurrentelectricpowerplant AT rosyidapermatasari designmodelingofsavoniusdarrieusturbineforseacurrentelectricpowerplant AT muhammadsjahrulannas designmodelingofsavoniusdarrieusturbineforseacurrentelectricpowerplant |
_version_ |
1724372817217060864 |