DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT

Turbines convert the kinetic energy of ocean currents into electrical energy produced by the sea current electric power plant. This study aims to design a power generator turbine modeling that is carried out using the Computational Fluid Dynamic (CFD) approach by comparing the geometric performance...

Full description

Bibliographic Details
Main Authors: Boris Metheny, Rosyida Permatasari, Muhammad Sjahrul Annas
Format: Article
Language:Indonesian
Published: Universitas Mercu Buana 2020-11-01
Series:Jurnal Ilmiah SINERGI
Subjects:
cfd
tsr
Online Access:https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8137
id doaj-af688f7795fe41d4a34a02d9a8b1c871
record_format Article
spelling doaj-af688f7795fe41d4a34a02d9a8b1c8712020-12-23T09:12:39ZindUniversitas Mercu BuanaJurnal Ilmiah SINERGI1410-23312460-12172020-11-01251273210.22441/sinergi.2021.1.0043785DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANTBoris Metheny0Rosyida Permatasari1Muhammad Sjahrul Annas2Department of Mechanical Engineering, Universitas TrisaktiDepartment of Mechanical Engineering, Universitas TrisaktiDepartment of Mechanical Engineering, Universitas TrisaktiTurbines convert the kinetic energy of ocean currents into electrical energy produced by the sea current electric power plant. This study aims to design a power generator turbine modeling that is carried out using the Computational Fluid Dynamic (CFD) approach by comparing the geometric performance based on the angle of attack and the Tip Speed Ratio (TSR) value of the Savonius-Darrieus Turbine. Having done several trials and errors during collecting the data, the value of the TSR 1.427; 2.853; 4.28; 5; and 5.7 is proposed. Here, the NACA 0018 series has been adopted on the current design of Savonius-Darrieus Turbine. The turbine has three blades, length of the span 357 mm, the diameter of turbine 428 mm, and length of the hydrofoil chord 40 mm. Effect of various angle of attacks from 0°up to 10° has been taken into account in the computational to obtain the coefficient power for each variation. The results revealed that the turbine with an angle of attack of 5°and TSR value of 5.0 has higher power coefficient value by 0.469 as compared with its angle of attack of 10°. It should be noted here that the increase of the angle of attack up to 10° resulted in a significant reduction of the power coefficient value of 0.206 as the value of TSR about 4.28. The addition of the Savonius Rotor results in increasing efficiency of the turbine for sea current applications.https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8137angle of attackcfdcoefficient of powersavonius-darrieus turbinetsr
collection DOAJ
language Indonesian
format Article
sources DOAJ
author Boris Metheny
Rosyida Permatasari
Muhammad Sjahrul Annas
spellingShingle Boris Metheny
Rosyida Permatasari
Muhammad Sjahrul Annas
DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
Jurnal Ilmiah SINERGI
angle of attack
cfd
coefficient of power
savonius-darrieus turbine
tsr
author_facet Boris Metheny
Rosyida Permatasari
Muhammad Sjahrul Annas
author_sort Boris Metheny
title DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
title_short DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
title_full DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
title_fullStr DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
title_full_unstemmed DESIGN MODELING OF SAVONIUS-DARRIEUS TURBINE FOR SEA CURRENT ELECTRIC POWER PLANT
title_sort design modeling of savonius-darrieus turbine for sea current electric power plant
publisher Universitas Mercu Buana
series Jurnal Ilmiah SINERGI
issn 1410-2331
2460-1217
publishDate 2020-11-01
description Turbines convert the kinetic energy of ocean currents into electrical energy produced by the sea current electric power plant. This study aims to design a power generator turbine modeling that is carried out using the Computational Fluid Dynamic (CFD) approach by comparing the geometric performance based on the angle of attack and the Tip Speed Ratio (TSR) value of the Savonius-Darrieus Turbine. Having done several trials and errors during collecting the data, the value of the TSR 1.427; 2.853; 4.28; 5; and 5.7 is proposed. Here, the NACA 0018 series has been adopted on the current design of Savonius-Darrieus Turbine. The turbine has three blades, length of the span 357 mm, the diameter of turbine 428 mm, and length of the hydrofoil chord 40 mm. Effect of various angle of attacks from 0°up to 10° has been taken into account in the computational to obtain the coefficient power for each variation. The results revealed that the turbine with an angle of attack of 5°and TSR value of 5.0 has higher power coefficient value by 0.469 as compared with its angle of attack of 10°. It should be noted here that the increase of the angle of attack up to 10° resulted in a significant reduction of the power coefficient value of 0.206 as the value of TSR about 4.28. The addition of the Savonius Rotor results in increasing efficiency of the turbine for sea current applications.
topic angle of attack
cfd
coefficient of power
savonius-darrieus turbine
tsr
url https://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/8137
work_keys_str_mv AT borismetheny designmodelingofsavoniusdarrieusturbineforseacurrentelectricpowerplant
AT rosyidapermatasari designmodelingofsavoniusdarrieusturbineforseacurrentelectricpowerplant
AT muhammadsjahrulannas designmodelingofsavoniusdarrieusturbineforseacurrentelectricpowerplant
_version_ 1724372817217060864