Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report

Abstract Background Transcatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing t...

Full description

Bibliographic Details
Main Authors: Lukasz Kmiec, Andreas Holzamer, Marcus Fischer, Kurt Debl, Matthäus Zerdzitzki, Christof Schmid, Lars Maier, Michael Hilker, Samuel Sossalla
Format: Article
Language:English
Published: BMC 2020-09-01
Series:Journal of Medical Case Reports
Subjects:
PCI
Online Access:http://link.springer.com/article/10.1186/s13256-020-02474-x
id doaj-aef616f990e44b4abd3512aa70cc0305
record_format Article
spelling doaj-aef616f990e44b4abd3512aa70cc03052020-11-25T03:21:31ZengBMCJournal of Medical Case Reports1752-19472020-09-011411510.1186/s13256-020-02474-xProtected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case reportLukasz Kmiec0Andreas Holzamer1Marcus Fischer2Kurt Debl3Matthäus Zerdzitzki4Christof Schmid5Lars Maier6Michael Hilker7Samuel Sossalla8Department of Cardiothoracic Surgery, University Medical Center RegensburgDepartment of Cardiothoracic Surgery, University Medical Center RegensburgDepartment of Internal Medicine II, University Medical Center RegensburgDepartment of Internal Medicine II, University Medical Center RegensburgDepartment of Cardiothoracic Surgery, University Medical Center RegensburgDepartment of Cardiothoracic Surgery, University Medical Center RegensburgDepartment of Internal Medicine II, University Medical Center RegensburgDepartment of Cardiothoracic Surgery, University Medical Center RegensburgDepartment of Internal Medicine II, University Medical Center RegensburgAbstract Background Transcatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing transcatheter aortic valve replacement and eventually concomitant complex percutaneous coronary intervention. Case presentation We present a successful procedure of transcatheter aortic valve replacement and high-risk percutaneous coronary intervention utilizing venoarterial extracorporeal membrane oxygenation for hemodynamic support in a very frail 88-year-old Caucasian woman with severe symptomatic aortic stenosis and coronary bypass grafting in the past. Echocardiography revealed a “low-flow low-gradient” aortic stenosis (mean transvalvular gradient 30 mmHg, aortic valve area 0.4 cm2, significant calcification), a left ventricular ejection fraction of 35%, severe mitral regurgitation with moderate stenosis (mean transvalvular gradient 7 mmHg), with a systolic pulmonary artery pressure of 80 mmHg. Moreover, pre-interventional coronary angiography exposed a severe left main ostial stenosis and sequential subtotal heavily calcified stenosis of the left anterior descending artery . Computed tomographic angiography showed no heavy tortuosity but moderate calcification of the iliofemoral arteries. The procedure was performed under general anesthesia in our hybrid operating room. Extracorporeal membrane oxygenation was established by left femoral percutaneous cannulation using a 21-Fr venous and 15-Fr arterial cannula. Subsequently, complex percutaneous coronary intervention with implantation of two drug-eluting stents from the left main into the left anterior descending artery was performed via a right femoral arterial 7F sheath. Thereafter, a 23-mm Sapien 3 aortic valve prosthesis (Edwards, Irvine, CA, USA) was implanted via right femoral artery in the usual manner, whereby the arterial pigtail catheter for marking the aortic annulus during transcatheter aortic valve replacement was inserted over a Check-Flo® Hemostasis Assembly (Cook Medical, Bloomington, IN, USA) on a Y-adapter via the arterial extracorporeal membrane oxygenation cannula. After extracorporeal membrane oxygenation decannulation, vascular closure was easily performed using the MANTA vascular closure device in order to reduce procedural time and risk of access site complications. Conclusions In summary, we demonstrate the feasibility of elective prophylactic extracorporeal membrane oxygenation implementation in selected very high-risk and frail patients undergoing transcatheter aortic valve replacement and percutaneous coronary intervention in order to avoid intraprocedural complications.http://link.springer.com/article/10.1186/s13256-020-02474-xTAVRPCIECMOvascular closure devicecase report
collection DOAJ
language English
format Article
sources DOAJ
author Lukasz Kmiec
Andreas Holzamer
Marcus Fischer
Kurt Debl
Matthäus Zerdzitzki
Christof Schmid
Lars Maier
Michael Hilker
Samuel Sossalla
spellingShingle Lukasz Kmiec
Andreas Holzamer
Marcus Fischer
Kurt Debl
Matthäus Zerdzitzki
Christof Schmid
Lars Maier
Michael Hilker
Samuel Sossalla
Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
Journal of Medical Case Reports
TAVR
PCI
ECMO
vascular closure device
case report
author_facet Lukasz Kmiec
Andreas Holzamer
Marcus Fischer
Kurt Debl
Matthäus Zerdzitzki
Christof Schmid
Lars Maier
Michael Hilker
Samuel Sossalla
author_sort Lukasz Kmiec
title Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_short Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_full Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_fullStr Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_full_unstemmed Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_sort protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
publisher BMC
series Journal of Medical Case Reports
issn 1752-1947
publishDate 2020-09-01
description Abstract Background Transcatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing transcatheter aortic valve replacement and eventually concomitant complex percutaneous coronary intervention. Case presentation We present a successful procedure of transcatheter aortic valve replacement and high-risk percutaneous coronary intervention utilizing venoarterial extracorporeal membrane oxygenation for hemodynamic support in a very frail 88-year-old Caucasian woman with severe symptomatic aortic stenosis and coronary bypass grafting in the past. Echocardiography revealed a “low-flow low-gradient” aortic stenosis (mean transvalvular gradient 30 mmHg, aortic valve area 0.4 cm2, significant calcification), a left ventricular ejection fraction of 35%, severe mitral regurgitation with moderate stenosis (mean transvalvular gradient 7 mmHg), with a systolic pulmonary artery pressure of 80 mmHg. Moreover, pre-interventional coronary angiography exposed a severe left main ostial stenosis and sequential subtotal heavily calcified stenosis of the left anterior descending artery . Computed tomographic angiography showed no heavy tortuosity but moderate calcification of the iliofemoral arteries. The procedure was performed under general anesthesia in our hybrid operating room. Extracorporeal membrane oxygenation was established by left femoral percutaneous cannulation using a 21-Fr venous and 15-Fr arterial cannula. Subsequently, complex percutaneous coronary intervention with implantation of two drug-eluting stents from the left main into the left anterior descending artery was performed via a right femoral arterial 7F sheath. Thereafter, a 23-mm Sapien 3 aortic valve prosthesis (Edwards, Irvine, CA, USA) was implanted via right femoral artery in the usual manner, whereby the arterial pigtail catheter for marking the aortic annulus during transcatheter aortic valve replacement was inserted over a Check-Flo® Hemostasis Assembly (Cook Medical, Bloomington, IN, USA) on a Y-adapter via the arterial extracorporeal membrane oxygenation cannula. After extracorporeal membrane oxygenation decannulation, vascular closure was easily performed using the MANTA vascular closure device in order to reduce procedural time and risk of access site complications. Conclusions In summary, we demonstrate the feasibility of elective prophylactic extracorporeal membrane oxygenation implementation in selected very high-risk and frail patients undergoing transcatheter aortic valve replacement and percutaneous coronary intervention in order to avoid intraprocedural complications.
topic TAVR
PCI
ECMO
vascular closure device
case report
url http://link.springer.com/article/10.1186/s13256-020-02474-x
work_keys_str_mv AT lukaszkmiec protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT andreasholzamer protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT marcusfischer protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT kurtdebl protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT matthauszerdzitzki protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT christofschmid protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT larsmaier protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT michaelhilker protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT samuelsossalla protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
_version_ 1724614092266668032