Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review
Computer-assisted surgery (CAS) in maxillary reconstruction has proven its value regarding more predictable postoperative results. However, the accuracy evaluation methods differ between studies, and no meta-analysis has been performed yet. A systematic review was performed in the PubMed, Embase, an...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-03-01
|
Series: | Journal of Clinical Medicine |
Subjects: | |
Online Access: | https://www.mdpi.com/2077-0383/10/6/1226 |
id |
doaj-aeea0665cf06485598a3b9968b35f859 |
---|---|
record_format |
Article |
spelling |
doaj-aeea0665cf06485598a3b9968b35f8592021-03-17T00:03:12ZengMDPI AGJournal of Clinical Medicine2077-03832021-03-01101226122610.3390/jcm10061226Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic ReviewGustaaf J. C. van Baar0Kitty Schipper1Tymour Forouzanfar2Lars Leeuwrik3Henri A. H. Winters4Angela Ridwan-Pramana5Frank K. J. Leusink6Department of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsDepartment of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsDepartment of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsDepartment of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsDepartment of Plastic, Reconstructive and Hand Surgery, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsDepartment of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsDepartment of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV Amsterdam, The NetherlandsComputer-assisted surgery (CAS) in maxillary reconstruction has proven its value regarding more predictable postoperative results. However, the accuracy evaluation methods differ between studies, and no meta-analysis has been performed yet. A systematic review was performed in the PubMed, Embase, and Cochrane Library databases, using a Patient, Intervention, Comparison and Outcome (PICO) method: (P) patients in need of maxillary reconstruction using free osteocutaneous tissue transfer, (I) reconstructed according to a virtual plan in CAS software, (C) compared to the actual postoperative result, and (O) postoperatively measured by a quantitative accuracy assessment) search strategy, and was reported according to the PRISMA statement. We reviewed all of the studies that quantitatively assessed the accuracy of maxillary reconstructions using CAS. Twelve studies matched the inclusion criteria, reporting 67 maxillary reconstructions. All of the included studies compared postoperative 3D models to preoperative 3D models (revised to the virtual plan). The postoperative accuracy measurements mainly focused on the position of the fibular bony segments. Only approximate comparisons of postoperative accuracy between studies were feasible because of small differences in the postoperative measurement methods; the accuracy of the bony segment positioning ranged between 0.44 mm and 7.8 mm, and between 2.90° and 6.96°. A postoperative evaluation guideline to create uniformity in evaluation methods needs to be considered so as to allow for valid comparisons of postoperative results and to facilitate meta-analyses in the future. With the proper validation of the postoperative results, future research might explore more definitive evidence regarding the management and superiority of CAS in maxillary and midface reconstruction.https://www.mdpi.com/2077-0383/10/6/1226maxillofacial reconstructionfree tissue flapssurgerycomputer-assistedcomputer-aided designcomputer-aided manufacturing |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gustaaf J. C. van Baar Kitty Schipper Tymour Forouzanfar Lars Leeuwrik Henri A. H. Winters Angela Ridwan-Pramana Frank K. J. Leusink |
spellingShingle |
Gustaaf J. C. van Baar Kitty Schipper Tymour Forouzanfar Lars Leeuwrik Henri A. H. Winters Angela Ridwan-Pramana Frank K. J. Leusink Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review Journal of Clinical Medicine maxillofacial reconstruction free tissue flaps surgery computer-assisted computer-aided design computer-aided manufacturing |
author_facet |
Gustaaf J. C. van Baar Kitty Schipper Tymour Forouzanfar Lars Leeuwrik Henri A. H. Winters Angela Ridwan-Pramana Frank K. J. Leusink |
author_sort |
Gustaaf J. C. van Baar |
title |
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review |
title_short |
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review |
title_full |
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review |
title_fullStr |
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review |
title_full_unstemmed |
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review |
title_sort |
accuracy of computer-assisted surgery in maxillary reconstruction: a systematic review |
publisher |
MDPI AG |
series |
Journal of Clinical Medicine |
issn |
2077-0383 |
publishDate |
2021-03-01 |
description |
Computer-assisted surgery (CAS) in maxillary reconstruction has proven its value regarding more predictable postoperative results. However, the accuracy evaluation methods differ between studies, and no meta-analysis has been performed yet. A systematic review was performed in the PubMed, Embase, and Cochrane Library databases, using a Patient, Intervention, Comparison and Outcome (PICO) method: (P) patients in need of maxillary reconstruction using free osteocutaneous tissue transfer, (I) reconstructed according to a virtual plan in CAS software, (C) compared to the actual postoperative result, and (O) postoperatively measured by a quantitative accuracy assessment) search strategy, and was reported according to the PRISMA statement. We reviewed all of the studies that quantitatively assessed the accuracy of maxillary reconstructions using CAS. Twelve studies matched the inclusion criteria, reporting 67 maxillary reconstructions. All of the included studies compared postoperative 3D models to preoperative 3D models (revised to the virtual plan). The postoperative accuracy measurements mainly focused on the position of the fibular bony segments. Only approximate comparisons of postoperative accuracy between studies were feasible because of small differences in the postoperative measurement methods; the accuracy of the bony segment positioning ranged between 0.44 mm and 7.8 mm, and between 2.90° and 6.96°. A postoperative evaluation guideline to create uniformity in evaluation methods needs to be considered so as to allow for valid comparisons of postoperative results and to facilitate meta-analyses in the future. With the proper validation of the postoperative results, future research might explore more definitive evidence regarding the management and superiority of CAS in maxillary and midface reconstruction. |
topic |
maxillofacial reconstruction free tissue flaps surgery computer-assisted computer-aided design computer-aided manufacturing |
url |
https://www.mdpi.com/2077-0383/10/6/1226 |
work_keys_str_mv |
AT gustaafjcvanbaar accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview AT kittyschipper accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview AT tymourforouzanfar accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview AT larsleeuwrik accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview AT henriahwinters accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview AT angelaridwanpramana accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview AT frankkjleusink accuracyofcomputerassistedsurgeryinmaxillaryreconstructionasystematicreview |
_version_ |
1724219131531624448 |