Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients

PURPOSE: The purpose of this study is to compare the accuracy of new generation formulas to standard formulas for intraocular lens (IOL) power calculations in pediatric patients. SUBJECTS AND METHODS: This retrospective case series compared the postoperative refractions to the predicted refractions...

Full description

Bibliographic Details
Main Author: Fouad Raja an-Nakhli
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Taiwan Journal of Ophthalmology
Subjects:
Online Access:http://www.e-tjo.org/article.asp?issn=2211-5056;year=2019;volume=9;issue=1;spage=37;epage=42;aulast=an-Nakhli
id doaj-aedda1ed1c58480f8586723297d2c65c
record_format Article
spelling doaj-aedda1ed1c58480f8586723297d2c65c2020-11-25T00:46:34ZengWolters Kluwer Medknow PublicationsTaiwan Journal of Ophthalmology2211-50562211-50722019-01-0191374210.4103/tjo.tjo_71_18Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patientsFouad Raja an-NakhliPURPOSE: The purpose of this study is to compare the accuracy of new generation formulas to standard formulas for intraocular lens (IOL) power calculations in pediatric patients. SUBJECTS AND METHODS: This retrospective case series compared the postoperative refractions to the predicted refractions after lensectomy and IOL implantation in pediatric patients. Four new generation formulas (Haigis, Holladay II, Olsen, and Barrett Universal II) were compared to four standard formulas (Holladay I, Hoffer Q, SRK/T, and SRKII) 4. The absolute prediction error (APE) was calculated as the absolute difference between the actual postoperative spherical equivalent and predicted spherical equivalent). The Friedman test was used to evaluate the difference between formulas. P < 0.05 was statistically significant. RESULTS: The study sample was comprised 44 eyes from 29 patients (20 males and 9 females) with median age at surgery of 2.85 years (2.04–6.14 years). The Holladay I and II, Barrett Universal II, SRK/T, SRKII, Olsen, and Hoffer Q formulas had comparable median APE (MedAPE) of 1.32 D (0.51–2.11 D), 1.34 D (0.82–1.94 D), 1.28 D (0.73–1.85 D), 1.26 D (0.60–2.08 D), 1.16 D (0.54–1.16 D), 1.34 D (0.80–1.98 D), and 1.27 D (0.63–2.08 D), respectively (P = 1.0). The Haigis formula had the statistically highest MedAPE of 2.00 D (1.27–3.04 D) (P < 0.001). More than 70% of eyes were within ±2.0 D for the Holladay I and II, Barrett Universal II, SRK/T, SRKII, Olsen, and Hoffer Q formulas. Fifty percent of eyes were within ±2.0 D for the Haigis formula. CONCLUSION: New generation IOL formulas do not outperform standard IOL formulas in predicting postoperative refraction for pediatric patients.http://www.e-tjo.org/article.asp?issn=2211-5056;year=2019;volume=9;issue=1;spage=37;epage=42;aulast=an-NakhliChildrenintraocular lens formulaintraocular lens powerpediatricprediction error
collection DOAJ
language English
format Article
sources DOAJ
author Fouad Raja an-Nakhli
spellingShingle Fouad Raja an-Nakhli
Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
Taiwan Journal of Ophthalmology
Children
intraocular lens formula
intraocular lens power
pediatric
prediction error
author_facet Fouad Raja an-Nakhli
author_sort Fouad Raja an-Nakhli
title Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
title_short Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
title_full Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
title_fullStr Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
title_full_unstemmed Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients
title_sort accuracy of new and standard intraocular lens power calculations formulae in saudi pediatric patients
publisher Wolters Kluwer Medknow Publications
series Taiwan Journal of Ophthalmology
issn 2211-5056
2211-5072
publishDate 2019-01-01
description PURPOSE: The purpose of this study is to compare the accuracy of new generation formulas to standard formulas for intraocular lens (IOL) power calculations in pediatric patients. SUBJECTS AND METHODS: This retrospective case series compared the postoperative refractions to the predicted refractions after lensectomy and IOL implantation in pediatric patients. Four new generation formulas (Haigis, Holladay II, Olsen, and Barrett Universal II) were compared to four standard formulas (Holladay I, Hoffer Q, SRK/T, and SRKII) 4. The absolute prediction error (APE) was calculated as the absolute difference between the actual postoperative spherical equivalent and predicted spherical equivalent). The Friedman test was used to evaluate the difference between formulas. P < 0.05 was statistically significant. RESULTS: The study sample was comprised 44 eyes from 29 patients (20 males and 9 females) with median age at surgery of 2.85 years (2.04–6.14 years). The Holladay I and II, Barrett Universal II, SRK/T, SRKII, Olsen, and Hoffer Q formulas had comparable median APE (MedAPE) of 1.32 D (0.51–2.11 D), 1.34 D (0.82–1.94 D), 1.28 D (0.73–1.85 D), 1.26 D (0.60–2.08 D), 1.16 D (0.54–1.16 D), 1.34 D (0.80–1.98 D), and 1.27 D (0.63–2.08 D), respectively (P = 1.0). The Haigis formula had the statistically highest MedAPE of 2.00 D (1.27–3.04 D) (P < 0.001). More than 70% of eyes were within ±2.0 D for the Holladay I and II, Barrett Universal II, SRK/T, SRKII, Olsen, and Hoffer Q formulas. Fifty percent of eyes were within ±2.0 D for the Haigis formula. CONCLUSION: New generation IOL formulas do not outperform standard IOL formulas in predicting postoperative refraction for pediatric patients.
topic Children
intraocular lens formula
intraocular lens power
pediatric
prediction error
url http://www.e-tjo.org/article.asp?issn=2211-5056;year=2019;volume=9;issue=1;spage=37;epage=42;aulast=an-Nakhli
work_keys_str_mv AT fouadrajaannakhli accuracyofnewandstandardintraocularlenspowercalculationsformulaeinsaudipediatricpatients
_version_ 1725264389460721664