Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study

To evaluate the influence of deployment strategy on the mechanical interaction between braided stent and parent artery of intracranial aneurysm (the elasticity of the arterial wall is considered), finite-element analyses are carried out by referring to computational models of flow-diverter device an...

Full description

Bibliographic Details
Main Authors: Wenyu Fu, Qixiao Xia
Format: Article
Language:English
Published: Hindawi Limited 2017-01-01
Series:Applied Bionics and Biomechanics
Online Access:http://dx.doi.org/10.1155/2017/3751202
id doaj-ae926163c7c147d8bba8a3ebcc43d8ea
record_format Article
spelling doaj-ae926163c7c147d8bba8a3ebcc43d8ea2021-07-02T03:29:14ZengHindawi LimitedApplied Bionics and Biomechanics1176-23221754-21032017-01-01201710.1155/2017/37512023751202Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational StudyWenyu Fu0Qixiao Xia1College of Mechanical and Electrical Engineering, Beijing Union University, Beijing 100020, ChinaCollege of Mechanical and Electrical Engineering, Beijing Union University, Beijing 100020, ChinaTo evaluate the influence of deployment strategy on the mechanical interaction between braided stent and parent artery of intracranial aneurysm (the elasticity of the arterial wall is considered), finite-element analyses are carried out by referring to computational models of flow-diverter device and arterial wall. Two implantation strategies are used to virtually implant the braided stent into the ideal intracranial aneurysm model. One is the noncompacted implantation method, and the other is the implantation method of using push-pull technique. During the process of the implantation, the changes of the arterial shape around the aneurysm and the changes of the wall pressure at the contact area between the braided stent and the inner wall of the artery are analyzed. The results indicate that the average contact pressure in the area of low porosity is 57 mmHg using the push-pull technique, and the average contact pressure of the parent artery is 10.45 mmHg using the non-push-pull technique. The diameter of the parent artery at the aneurismal orifice increased about 0.2 mm when using the push-pull technique, so the elasticity of the vessel should be considered in the mechanical analysis of interaction between stent and vessel.http://dx.doi.org/10.1155/2017/3751202
collection DOAJ
language English
format Article
sources DOAJ
author Wenyu Fu
Qixiao Xia
spellingShingle Wenyu Fu
Qixiao Xia
Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
Applied Bionics and Biomechanics
author_facet Wenyu Fu
Qixiao Xia
author_sort Wenyu Fu
title Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
title_short Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
title_full Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
title_fullStr Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
title_full_unstemmed Interaction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
title_sort interaction between flow diverter and parent artery of intracranial aneurysm: a computational study
publisher Hindawi Limited
series Applied Bionics and Biomechanics
issn 1176-2322
1754-2103
publishDate 2017-01-01
description To evaluate the influence of deployment strategy on the mechanical interaction between braided stent and parent artery of intracranial aneurysm (the elasticity of the arterial wall is considered), finite-element analyses are carried out by referring to computational models of flow-diverter device and arterial wall. Two implantation strategies are used to virtually implant the braided stent into the ideal intracranial aneurysm model. One is the noncompacted implantation method, and the other is the implantation method of using push-pull technique. During the process of the implantation, the changes of the arterial shape around the aneurysm and the changes of the wall pressure at the contact area between the braided stent and the inner wall of the artery are analyzed. The results indicate that the average contact pressure in the area of low porosity is 57 mmHg using the push-pull technique, and the average contact pressure of the parent artery is 10.45 mmHg using the non-push-pull technique. The diameter of the parent artery at the aneurismal orifice increased about 0.2 mm when using the push-pull technique, so the elasticity of the vessel should be considered in the mechanical analysis of interaction between stent and vessel.
url http://dx.doi.org/10.1155/2017/3751202
work_keys_str_mv AT wenyufu interactionbetweenflowdiverterandparentarteryofintracranialaneurysmacomputationalstudy
AT qixiaoxia interactionbetweenflowdiverterandparentarteryofintracranialaneurysmacomputationalstudy
_version_ 1721341519663726592