Bond strength of hot – dip galvanized reinforcement (B500B) with concrete

This paper evaluates the effect of initial corrosion damage to the surface of the hot - dip galvanized steel coating in fresh concrete on its final bond strength. The tests were performed on uncoated and hot-dip galvanized ribbed reinforcements. The measurement of bond stress (τ<sub>m</sub&...

Full description

Bibliographic Details
Main Authors: P. Pokorný, D. Dobiáš, M. Vokáč
Format: Article
Language:English
Published: Croatian Metallurgical Society 2016-07-01
Series:Metalurgija
Subjects:
Online Access:http://hrcak.srce.hr/file/226313
id doaj-adc10c75f9994dca91765212ba466c16
record_format Article
spelling doaj-adc10c75f9994dca91765212ba466c162020-11-24T23:48:28ZengCroatian Metallurgical SocietyMetalurgija0543-58461334-25762016-07-01553337340Bond strength of hot – dip galvanized reinforcement (B500B) with concrete P. PokornýD. DobiášM. VokáčThis paper evaluates the effect of initial corrosion damage to the surface of the hot - dip galvanized steel coating in fresh concrete on its final bond strength. The tests were performed on uncoated and hot-dip galvanized ribbed reinforcements. The measurement of bond stress (τ<sub>m</sub>) according to the standard procedure (ASTM C234; ČSN 73 1328) revealed decreased bond strength of the coated reinforcement. Both types of reinforcement exhibit similar values of maximum shear stress (τ). To make some general conclusion, the bond strength also needs to be verified on smooth profiles.http://hrcak.srce.hr/file/226313corrosionsteelhot-dip galvanized coatingpull – out testASTM C234
collection DOAJ
language English
format Article
sources DOAJ
author P. Pokorný
D. Dobiáš
M. Vokáč
spellingShingle P. Pokorný
D. Dobiáš
M. Vokáč
Bond strength of hot – dip galvanized reinforcement (B500B) with concrete
Metalurgija
corrosion
steel
hot-dip galvanized coating
pull – out test
ASTM C234
author_facet P. Pokorný
D. Dobiáš
M. Vokáč
author_sort P. Pokorný
title Bond strength of hot – dip galvanized reinforcement (B500B) with concrete
title_short Bond strength of hot – dip galvanized reinforcement (B500B) with concrete
title_full Bond strength of hot – dip galvanized reinforcement (B500B) with concrete
title_fullStr Bond strength of hot – dip galvanized reinforcement (B500B) with concrete
title_full_unstemmed Bond strength of hot – dip galvanized reinforcement (B500B) with concrete
title_sort bond strength of hot – dip galvanized reinforcement (b500b) with concrete
publisher Croatian Metallurgical Society
series Metalurgija
issn 0543-5846
1334-2576
publishDate 2016-07-01
description This paper evaluates the effect of initial corrosion damage to the surface of the hot - dip galvanized steel coating in fresh concrete on its final bond strength. The tests were performed on uncoated and hot-dip galvanized ribbed reinforcements. The measurement of bond stress (τ<sub>m</sub>) according to the standard procedure (ASTM C234; ČSN 73 1328) revealed decreased bond strength of the coated reinforcement. Both types of reinforcement exhibit similar values of maximum shear stress (τ). To make some general conclusion, the bond strength also needs to be verified on smooth profiles.
topic corrosion
steel
hot-dip galvanized coating
pull – out test
ASTM C234