[Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]

Background. The acute coronary insufficiency is a common pathology in the practice of forensic experts. A small window of opportunity to study changes in myocardial tissue after death is a challenge for forensic experts. It is known that the established methods of detecting lesions of acute ischemia...

Full description

Bibliographic Details
Main Author: Vanchuliak O.Ya.
Format: Article
Language:Russian
Published: Ministry of Health of Ukraine. Dnipropetrovsk Medical Academy 2015-06-01
Series:Морфологія
Subjects:
Online Access:http://www.morphology.dp.ua/_pub/MORPHO-2015-09-02/15voysfa.pdf
id doaj-ad9f56cb39be4f11a632c8c1c0cfd1b9
record_format Article
spelling doaj-ad9f56cb39be4f11a632c8c1c0cfd1b92020-11-25T00:20:24ZrusMinistry of Health of Ukraine. Dnipropetrovsk Medical Academy Морфологія1997-96651997-96652015-06-01922428[Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]Vanchuliak O.Ya.0Bukovinian State Medical University, ChernivtsiBackground. The acute coronary insufficiency is a common pathology in the practice of forensic experts. A small window of opportunity to study changes in myocardial tissue after death is a challenge for forensic experts. It is known that the established methods of detecting lesions of acute ischemia that are used in forensic practice need to be considerably updated since they depend on a multitude of internal and external environmental factors, require expensive reagents and are time consuming. These are precise reasons for searching and improving existing methods of diagnostics of myocardial changes to develop objective criteria for forensic determination of acute ischemic myocardial injury. Objective. To study the structure of the human myocardium under the acute coronary insufficiency using Mueller - matrix analysis of the optical anisotropy myosin networks of myocardium using a statistical and fractal approach. Methods. The study of myocardial samples was conducted with a laser polarimeter with subsequent analysis of the results in the MathLab 6 program. The object of the study was native myocardial sections of people who died as a result of acute coronary insufficiency and chronic ischemic heart disease. Results. We have revealed that in acute coronary insufficiency there was a decrease (20-fold) in the number of extreme values of the "orientational" Mueller matrix element of myocardial tissue. In other words, there is a clear disorientation of the optical axes of myosin fibrils in cases of acute coronary insufficiency comparing with chronic ischemic heart disease. Conclusion. We can assert the essential diagnostic sensitivity of laser polarimetry to differentiate death due to chronic ischemic heart disease and acute coronary insufficiency. Citation: Vanchuliak OYa. [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]. Morphologia. 2015;9(2):24-8. Ukrainian. http://www.morphology.dp.ua/_pub/MORPHO-2015-09-02/15voysfa.pdfsudden cardiac deathforensic medical examination of the myocardial structurediagnostics
collection DOAJ
language Russian
format Article
sources DOAJ
author Vanchuliak O.Ya.
spellingShingle Vanchuliak O.Ya.
[Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]
Морфологія
sudden cardiac death
forensic medical examination of the myocardial structure
diagnostics
author_facet Vanchuliak O.Ya.
author_sort Vanchuliak O.Ya.
title [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]
title_short [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]
title_full [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]
title_fullStr [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]
title_full_unstemmed [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]
title_sort [diagnostics of the acute coronary insufficiency by the method of muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. a statistical and fractal approach]
publisher Ministry of Health of Ukraine. Dnipropetrovsk Medical Academy
series Морфологія
issn 1997-9665
1997-9665
publishDate 2015-06-01
description Background. The acute coronary insufficiency is a common pathology in the practice of forensic experts. A small window of opportunity to study changes in myocardial tissue after death is a challenge for forensic experts. It is known that the established methods of detecting lesions of acute ischemia that are used in forensic practice need to be considerably updated since they depend on a multitude of internal and external environmental factors, require expensive reagents and are time consuming. These are precise reasons for searching and improving existing methods of diagnostics of myocardial changes to develop objective criteria for forensic determination of acute ischemic myocardial injury. Objective. To study the structure of the human myocardium under the acute coronary insufficiency using Mueller - matrix analysis of the optical anisotropy myosin networks of myocardium using a statistical and fractal approach. Methods. The study of myocardial samples was conducted with a laser polarimeter with subsequent analysis of the results in the MathLab 6 program. The object of the study was native myocardial sections of people who died as a result of acute coronary insufficiency and chronic ischemic heart disease. Results. We have revealed that in acute coronary insufficiency there was a decrease (20-fold) in the number of extreme values of the "orientational" Mueller matrix element of myocardial tissue. In other words, there is a clear disorientation of the optical axes of myosin fibrils in cases of acute coronary insufficiency comparing with chronic ischemic heart disease. Conclusion. We can assert the essential diagnostic sensitivity of laser polarimetry to differentiate death due to chronic ischemic heart disease and acute coronary insufficiency. Citation: Vanchuliak OYa. [Diagnostics of the acute coronary insufficiency by the method of Muller-matrix analysis of the optic anisotropy of myosin networks of the myocardium. A statistical and fractal approach]. Morphologia. 2015;9(2):24-8. Ukrainian.
topic sudden cardiac death
forensic medical examination of the myocardial structure
diagnostics
url http://www.morphology.dp.ua/_pub/MORPHO-2015-09-02/15voysfa.pdf
work_keys_str_mv AT vanchuliakoya diagnosticsoftheacutecoronaryinsufficiencybythemethodofmullermatrixanalysisoftheopticanisotropyofmyosinnetworksofthemyocardiumastatisticalandfractalapproach
_version_ 1725367959070703616