A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer

Abstract Ultrasonic method is widely used for the detection and location of partial discharge (PD) in transformer, however, the measured ultrasonic signal is usually corrupted by noise, and sometimes is even buried by noise entirely. Therefore, the de‐noising of the measured signal is essential. Con...

Full description

Bibliographic Details
Main Authors: Jiangrong Cheng, Yuan Xu, Dengwei Ding, Weidong Liu
Format: Article
Language:English
Published: Wiley 2021-05-01
Series:IET Science, Measurement & Technology
Online Access:https://doi.org/10.1049/smt2.12031
id doaj-ad3a67044a0345f2a0ddcc1ac1bda98b
record_format Article
spelling doaj-ad3a67044a0345f2a0ddcc1ac1bda98b2021-08-02T08:25:32ZengWileyIET Science, Measurement & Technology1751-88221751-88302021-05-0115330231110.1049/smt2.12031A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformerJiangrong Cheng0Yuan Xu1Dengwei Ding2Weidong Liu3Department of Electrical Engineering Tsinghua University Beijing ChinaChina Electric Power Research Institute Beijing ChinaSichuan Energy Internet Research Institute Tsinghua University Chengdu ChinaDepartment of Electrical Engineering Tsinghua University Beijing ChinaAbstract Ultrasonic method is widely used for the detection and location of partial discharge (PD) in transformer, however, the measured ultrasonic signal is usually corrupted by noise, and sometimes is even buried by noise entirely. Therefore, the de‐noising of the measured signal is essential. Conventional de‐nosing methods, such as wavelet method and singular value decomposition (SVD) method, generally require empirical parameter selection or estimation, and the best parameters for de‐noising vary with the PD source and noise condition, which will bring some limitation to their applicability. More importantly, conventional de‐noising methods usually have poor performance for the low signal‐to‐noise‐ratio (SNR) signals. To improve this problem, the paper proposes a de‐noising method based on coherence average for the ultrasonic signal. The de‐noising performance of the proposed method is evaluated based on a comparison with conventional methods, the results indicate that the proposed method has great de‐noising effect for the ultrasonic signals, even for the low‐SNR signals. Besides, the proposed method is free from empirical parameter selection or estimation, which can make its applicability more extensive. The proposed method can offer a practical and effective solution to the de‐noising of ultrasonic signal of PD in transformer.https://doi.org/10.1049/smt2.12031
collection DOAJ
language English
format Article
sources DOAJ
author Jiangrong Cheng
Yuan Xu
Dengwei Ding
Weidong Liu
spellingShingle Jiangrong Cheng
Yuan Xu
Dengwei Ding
Weidong Liu
A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
IET Science, Measurement & Technology
author_facet Jiangrong Cheng
Yuan Xu
Dengwei Ding
Weidong Liu
author_sort Jiangrong Cheng
title A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
title_short A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
title_full A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
title_fullStr A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
title_full_unstemmed A novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
title_sort novel de‐noising method based on coherence average for ultrasonic signal of partial discharge in transformer
publisher Wiley
series IET Science, Measurement & Technology
issn 1751-8822
1751-8830
publishDate 2021-05-01
description Abstract Ultrasonic method is widely used for the detection and location of partial discharge (PD) in transformer, however, the measured ultrasonic signal is usually corrupted by noise, and sometimes is even buried by noise entirely. Therefore, the de‐noising of the measured signal is essential. Conventional de‐nosing methods, such as wavelet method and singular value decomposition (SVD) method, generally require empirical parameter selection or estimation, and the best parameters for de‐noising vary with the PD source and noise condition, which will bring some limitation to their applicability. More importantly, conventional de‐noising methods usually have poor performance for the low signal‐to‐noise‐ratio (SNR) signals. To improve this problem, the paper proposes a de‐noising method based on coherence average for the ultrasonic signal. The de‐noising performance of the proposed method is evaluated based on a comparison with conventional methods, the results indicate that the proposed method has great de‐noising effect for the ultrasonic signals, even for the low‐SNR signals. Besides, the proposed method is free from empirical parameter selection or estimation, which can make its applicability more extensive. The proposed method can offer a practical and effective solution to the de‐noising of ultrasonic signal of PD in transformer.
url https://doi.org/10.1049/smt2.12031
work_keys_str_mv AT jiangrongcheng anoveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT yuanxu anoveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT dengweiding anoveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT weidongliu anoveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT jiangrongcheng noveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT yuanxu noveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT dengweiding noveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
AT weidongliu noveldenoisingmethodbasedoncoherenceaverageforultrasonicsignalofpartialdischargeintransformer
_version_ 1721238290601869312