Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.

Accurate and sensitive quantification of rebound competent HIV that persists despite combination antiretroviral treatment (cART), including in latently infected cells (i.e., viral reservoir), is critical for evaluating cure strategies for decreasing or eliminating this reservoir. Simian immunodefici...

Full description

Bibliographic Details
Main Authors: Samuel Long, Brian Berkemeier
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0240447
id doaj-ac6af003553d45168439b8cb9181d8a6
record_format Article
spelling doaj-ac6af003553d45168439b8cb9181d8a62021-03-04T11:11:02ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-011510e024044710.1371/journal.pone.0240447Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.Samuel LongBrian BerkemeierAccurate and sensitive quantification of rebound competent HIV that persists despite combination antiretroviral treatment (cART), including in latently infected cells (i.e., viral reservoir), is critical for evaluating cure strategies for decreasing or eliminating this reservoir. Simian immunodeficiency virus (SIV)-infected Rhesus macaques are an important non-human primate (NHP) system for studying potential cure strategies as they model many key aspects of human HIV-infection including the persistence of a latent viral reservoir in resting memory CD4+ T cells in animals receiving prolonged cART. In this report, we describe the design and testing of a sensitive SIV droplet digital PCR (ddPCR) assay through exploring the combination and optimization of different probe systems (including single, double quencher probes and minor groove binder (MGB) probes) and reaction conditions to eliminate background signal(s), ensure distinct target signal cluster separation from non-target signals, and enable detection and quantification of low level authentic target signals. Similar reaction conditions and assay validation procedures can be explored for potential development of additional assays for other applications that require sensitive detection of low-level targets in a large background of nucleic acid input derived from cell or tissue sources.https://doi.org/10.1371/journal.pone.0240447
collection DOAJ
language English
format Article
sources DOAJ
author Samuel Long
Brian Berkemeier
spellingShingle Samuel Long
Brian Berkemeier
Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.
PLoS ONE
author_facet Samuel Long
Brian Berkemeier
author_sort Samuel Long
title Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.
title_short Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.
title_full Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.
title_fullStr Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.
title_full_unstemmed Development and optimization of a simian immunodeficiency virus (SIV) droplet digital PCR (ddPCR) assay.
title_sort development and optimization of a simian immunodeficiency virus (siv) droplet digital pcr (ddpcr) assay.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2020-01-01
description Accurate and sensitive quantification of rebound competent HIV that persists despite combination antiretroviral treatment (cART), including in latently infected cells (i.e., viral reservoir), is critical for evaluating cure strategies for decreasing or eliminating this reservoir. Simian immunodeficiency virus (SIV)-infected Rhesus macaques are an important non-human primate (NHP) system for studying potential cure strategies as they model many key aspects of human HIV-infection including the persistence of a latent viral reservoir in resting memory CD4+ T cells in animals receiving prolonged cART. In this report, we describe the design and testing of a sensitive SIV droplet digital PCR (ddPCR) assay through exploring the combination and optimization of different probe systems (including single, double quencher probes and minor groove binder (MGB) probes) and reaction conditions to eliminate background signal(s), ensure distinct target signal cluster separation from non-target signals, and enable detection and quantification of low level authentic target signals. Similar reaction conditions and assay validation procedures can be explored for potential development of additional assays for other applications that require sensitive detection of low-level targets in a large background of nucleic acid input derived from cell or tissue sources.
url https://doi.org/10.1371/journal.pone.0240447
work_keys_str_mv AT samuellong developmentandoptimizationofasimianimmunodeficiencyvirussivdropletdigitalpcrddpcrassay
AT brianberkemeier developmentandoptimizationofasimianimmunodeficiencyvirussivdropletdigitalpcrddpcrassay
_version_ 1714804677680300032