Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error

The vascular function of a vessel can be qualitatively and intraoperatively checked by recording the blood dynamics inside the vessel via fluorescence angiography (FA). Although FA is the state of the art in proving the existence of blood flow during interventions such as bypass surgery, it still la...

Full description

Bibliographic Details
Main Authors: Ady Naber, Michael Reiß, Werner Nahm
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-05-01
Series:Frontiers in Physiology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fphys.2021.588120/full
id doaj-ac5bb01c99054600951d056a5ea99bed
record_format Article
spelling doaj-ac5bb01c99054600951d056a5ea99bed2021-05-28T09:32:02ZengFrontiers Media S.A.Frontiers in Physiology1664-042X2021-05-011210.3389/fphys.2021.588120588120Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the ErrorAdy NaberMichael ReißWerner NahmThe vascular function of a vessel can be qualitatively and intraoperatively checked by recording the blood dynamics inside the vessel via fluorescence angiography (FA). Although FA is the state of the art in proving the existence of blood flow during interventions such as bypass surgery, it still lacks a quantitative blood flow measurement that could decrease the recurrence rate and postsurgical mortality. Previous approaches show that the measured flow has a significant deviation compared to the gold standard reference (ultrasonic flow meter). In order to systematically address the possible sources of error, we investigated the error in transit time measurement of an indicator. Obtaining in vivo indicator dilution curves with a known ground truth is complex and often not possible. Further, the error in transit time measurement should be quantified and reduced. To tackle both issues, we first computed many diverse indicator dilution curves using an in silico simulation of the indicator's flow. Second, we post-processed these curves to mimic measured signals. Finally, we fitted mathematical models (parabola, gamma variate, local density random walk, and mono-exponential model) to re-continualize the obtained discrete indicator dilution curves and calculate the time delay of two analytical functions. This re-continualization showed an increase in the temporal accuracy up to a sub-sample accuracy. Thereby, the Local Density Random Walk (LDRW) model performed best using the cross-correlation of the first derivative of both indicator curves with a cutting of the data at 40% of the peak intensity. The error in frames depends on the noise level and is for a signal-to-noise ratio (SNR) of 20 dB and a sampling rate of fs = 60 Hz at fs-1·0.25(±0.18), so this error is smaller than the distance between two consecutive samples. The accurate determination of the transit time and the quantification of the error allow the calculation of the error propagation onto the flow measurement. Both can assist surgeons as an intraoperative quality check and thereby reduce the recurrence rate and post-surgical mortality.https://www.frontiersin.org/articles/10.3389/fphys.2021.588120/fullindicator dilution curvemathematical fitstransit timeblood flow velocityfluorescence angiographysub-frame rate accuracy
collection DOAJ
language English
format Article
sources DOAJ
author Ady Naber
Michael Reiß
Werner Nahm
spellingShingle Ady Naber
Michael Reiß
Werner Nahm
Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error
Frontiers in Physiology
indicator dilution curve
mathematical fits
transit time
blood flow velocity
fluorescence angiography
sub-frame rate accuracy
author_facet Ady Naber
Michael Reiß
Werner Nahm
author_sort Ady Naber
title Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error
title_short Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error
title_full Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error
title_fullStr Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error
title_full_unstemmed Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error
title_sort transit time measurement in indicator dilution curves: overcoming the missing ground truth and quantifying the error
publisher Frontiers Media S.A.
series Frontiers in Physiology
issn 1664-042X
publishDate 2021-05-01
description The vascular function of a vessel can be qualitatively and intraoperatively checked by recording the blood dynamics inside the vessel via fluorescence angiography (FA). Although FA is the state of the art in proving the existence of blood flow during interventions such as bypass surgery, it still lacks a quantitative blood flow measurement that could decrease the recurrence rate and postsurgical mortality. Previous approaches show that the measured flow has a significant deviation compared to the gold standard reference (ultrasonic flow meter). In order to systematically address the possible sources of error, we investigated the error in transit time measurement of an indicator. Obtaining in vivo indicator dilution curves with a known ground truth is complex and often not possible. Further, the error in transit time measurement should be quantified and reduced. To tackle both issues, we first computed many diverse indicator dilution curves using an in silico simulation of the indicator's flow. Second, we post-processed these curves to mimic measured signals. Finally, we fitted mathematical models (parabola, gamma variate, local density random walk, and mono-exponential model) to re-continualize the obtained discrete indicator dilution curves and calculate the time delay of two analytical functions. This re-continualization showed an increase in the temporal accuracy up to a sub-sample accuracy. Thereby, the Local Density Random Walk (LDRW) model performed best using the cross-correlation of the first derivative of both indicator curves with a cutting of the data at 40% of the peak intensity. The error in frames depends on the noise level and is for a signal-to-noise ratio (SNR) of 20 dB and a sampling rate of fs = 60 Hz at fs-1·0.25(±0.18), so this error is smaller than the distance between two consecutive samples. The accurate determination of the transit time and the quantification of the error allow the calculation of the error propagation onto the flow measurement. Both can assist surgeons as an intraoperative quality check and thereby reduce the recurrence rate and post-surgical mortality.
topic indicator dilution curve
mathematical fits
transit time
blood flow velocity
fluorescence angiography
sub-frame rate accuracy
url https://www.frontiersin.org/articles/10.3389/fphys.2021.588120/full
work_keys_str_mv AT adynaber transittimemeasurementinindicatordilutioncurvesovercomingthemissinggroundtruthandquantifyingtheerror
AT michaelreiß transittimemeasurementinindicatordilutioncurvesovercomingthemissinggroundtruthandquantifyingtheerror
AT wernernahm transittimemeasurementinindicatordilutioncurvesovercomingthemissinggroundtruthandquantifyingtheerror
_version_ 1721424363231641600