Coil Embolization of Arc of Buhler Aneurysm Rupture
The arc of Buhler (AOB) is a rare anatomical variant. Rupture of an AOB aneurysm is exceedingly rare. In this study, we report a case of AOB aneurysm rupture, which was successfully treated by transcatheter coil embolization. A 74-year-old man presented with symptomatic AOB aneurysm rupture. A compu...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2020-01-01
|
Series: | Case Reports in Radiology |
Online Access: | http://dx.doi.org/10.1155/2020/8855946 |
id |
doaj-ac17e070f67246fb912ccf4a4eaea4fa |
---|---|
record_format |
Article |
spelling |
doaj-ac17e070f67246fb912ccf4a4eaea4fa2020-12-21T11:41:29ZengHindawi LimitedCase Reports in Radiology2090-68622090-68702020-01-01202010.1155/2020/88559468855946Coil Embolization of Arc of Buhler Aneurysm RuptureDaniel Yuxuan Ong0Uei Pua1Department of Diagnostic Radiology, Tan Tock Seng Hospital, SingaporeDepartment of Diagnostic Radiology, Tan Tock Seng Hospital, SingaporeThe arc of Buhler (AOB) is a rare anatomical variant. Rupture of an AOB aneurysm is exceedingly rare. In this study, we report a case of AOB aneurysm rupture, which was successfully treated by transcatheter coil embolization. A 74-year-old man presented with symptomatic AOB aneurysm rupture. A computed tomography scan and subsequent angiography revealed the aberrant connection between the common hepatic artery and the superior mesenteric artery. A fusiform AOB aneurysm with focus of active bleeding was detected. This was successfully treated through embolization and sacrifice of the AOB. This suggests that conventional embolization with sacrifice of AOB is a feasible and safe approach.http://dx.doi.org/10.1155/2020/8855946 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Daniel Yuxuan Ong Uei Pua |
spellingShingle |
Daniel Yuxuan Ong Uei Pua Coil Embolization of Arc of Buhler Aneurysm Rupture Case Reports in Radiology |
author_facet |
Daniel Yuxuan Ong Uei Pua |
author_sort |
Daniel Yuxuan Ong |
title |
Coil Embolization of Arc of Buhler Aneurysm Rupture |
title_short |
Coil Embolization of Arc of Buhler Aneurysm Rupture |
title_full |
Coil Embolization of Arc of Buhler Aneurysm Rupture |
title_fullStr |
Coil Embolization of Arc of Buhler Aneurysm Rupture |
title_full_unstemmed |
Coil Embolization of Arc of Buhler Aneurysm Rupture |
title_sort |
coil embolization of arc of buhler aneurysm rupture |
publisher |
Hindawi Limited |
series |
Case Reports in Radiology |
issn |
2090-6862 2090-6870 |
publishDate |
2020-01-01 |
description |
The arc of Buhler (AOB) is a rare anatomical variant. Rupture of an AOB aneurysm is exceedingly rare. In this study, we report a case of AOB aneurysm rupture, which was successfully treated by transcatheter coil embolization. A 74-year-old man presented with symptomatic AOB aneurysm rupture. A computed tomography scan and subsequent angiography revealed the aberrant connection between the common hepatic artery and the superior mesenteric artery. A fusiform AOB aneurysm with focus of active bleeding was detected. This was successfully treated through embolization and sacrifice of the AOB. This suggests that conventional embolization with sacrifice of AOB is a feasible and safe approach. |
url |
http://dx.doi.org/10.1155/2020/8855946 |
work_keys_str_mv |
AT danielyuxuanong coilembolizationofarcofbuhleraneurysmrupture AT ueipua coilembolizationofarcofbuhleraneurysmrupture |
_version_ |
1714988381531799552 |