Assessment of desiccants and their instructions for use in rapid diagnostic tests

<p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are protected from humidity-caused degradation by a desiccant added to the device packaging. The present study assessed malaria RDT products for the availability, type and design of desiccants an...

Full description

Bibliographic Details
Main Authors: Barbé Barbara, Gillet Philippe, Beelaert Greet, Fransen Katrien, Jacobs Jan
Format: Article
Language:English
Published: BMC 2012-09-01
Series:Malaria Journal
Subjects:
HIV
Online Access:http://www.malariajournal.com/content/11/1/326
id doaj-ac176d74e56b4c48979aa6cc0de9b36a
record_format Article
spelling doaj-ac176d74e56b4c48979aa6cc0de9b36a2020-11-24T21:11:50ZengBMCMalaria Journal1475-28752012-09-0111132610.1186/1475-2875-11-326Assessment of desiccants and their instructions for use in rapid diagnostic testsBarbé BarbaraGillet PhilippeBeelaert GreetFransen KatrienJacobs Jan<p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are protected from humidity-caused degradation by a desiccant added to the device packaging. The present study assessed malaria RDT products for the availability, type and design of desiccants and their information supplied in the instructions for use (IFU).</p> <p>Methods</p> <p>Criteria were based on recommendations of the World Health Organization (WHO), the European Community (CE) and own observations. Silica gel sachets were defined as self-indicating (all beads coated with a humidity indicator that changes colour upon saturation), partial-indicating (part of beads coated) and non-indicating (none of the beads coated). Indicating silica gel sachets were individually assessed for humidity saturation and (in case of partial-indicating silica gels) for the presence of indicating beads.</p> <p>Results</p> <p>Fifty malaria RDT products from 25 manufacturers were assessed, 14 (28%) products were listed by the “Global Fund Quality Assurance Policy” and 31 (62%) were CE-marked. All but one product contained a desiccant, mostly (47/50, 94%) silica gel. Twenty (40%) RDT products (one with no desiccant and 19 with non-indicating desiccant) did not meet the WHO guidelines recommending indicating desiccant. All RDT products with self- or partial-indicating silica gel (n = 22 and 8 respectively) contained the toxic cobalt dichloride as humidity indicator. Colour change indicating humidity saturation was observed for 8/16 RDT products, at a median incidence of 0.8% (range 0.05%-4.6%) of sachets inspected. In all RDTs with partial-indicating silica gel, sachets with no colour indicating beads were found (median proportion 13.5% (0.6% - 17.8%) per product) and additional light was needed to assess the humidity colour. Less than half (14/30, 47%) IFUs of RDT products with indicating desiccants mentioned to check the humidity saturation before using the test. Information on properties, safety hazards and disposal of the desiccant was not included in any of the IFUs. There were no differences between Global Fund-listed and CE marked RDT products compared to those which were not. Similar findings were noted for a panel of 11 HIV RDTs that was assessed with the same checklist as the malaria RDTs.</p> <p>Conclusion</p> <p>RDTs showed shortcomings in desiccant type and information supplied in the IFU.</p> http://www.malariajournal.com/content/11/1/326DesiccantSilica gelRapid diagnostic testRDT-malariaHIVDiagnosis
collection DOAJ
language English
format Article
sources DOAJ
author Barbé Barbara
Gillet Philippe
Beelaert Greet
Fransen Katrien
Jacobs Jan
spellingShingle Barbé Barbara
Gillet Philippe
Beelaert Greet
Fransen Katrien
Jacobs Jan
Assessment of desiccants and their instructions for use in rapid diagnostic tests
Malaria Journal
Desiccant
Silica gel
Rapid diagnostic test
RDT-malaria
HIV
Diagnosis
author_facet Barbé Barbara
Gillet Philippe
Beelaert Greet
Fransen Katrien
Jacobs Jan
author_sort Barbé Barbara
title Assessment of desiccants and their instructions for use in rapid diagnostic tests
title_short Assessment of desiccants and their instructions for use in rapid diagnostic tests
title_full Assessment of desiccants and their instructions for use in rapid diagnostic tests
title_fullStr Assessment of desiccants and their instructions for use in rapid diagnostic tests
title_full_unstemmed Assessment of desiccants and their instructions for use in rapid diagnostic tests
title_sort assessment of desiccants and their instructions for use in rapid diagnostic tests
publisher BMC
series Malaria Journal
issn 1475-2875
publishDate 2012-09-01
description <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are protected from humidity-caused degradation by a desiccant added to the device packaging. The present study assessed malaria RDT products for the availability, type and design of desiccants and their information supplied in the instructions for use (IFU).</p> <p>Methods</p> <p>Criteria were based on recommendations of the World Health Organization (WHO), the European Community (CE) and own observations. Silica gel sachets were defined as self-indicating (all beads coated with a humidity indicator that changes colour upon saturation), partial-indicating (part of beads coated) and non-indicating (none of the beads coated). Indicating silica gel sachets were individually assessed for humidity saturation and (in case of partial-indicating silica gels) for the presence of indicating beads.</p> <p>Results</p> <p>Fifty malaria RDT products from 25 manufacturers were assessed, 14 (28%) products were listed by the “Global Fund Quality Assurance Policy” and 31 (62%) were CE-marked. All but one product contained a desiccant, mostly (47/50, 94%) silica gel. Twenty (40%) RDT products (one with no desiccant and 19 with non-indicating desiccant) did not meet the WHO guidelines recommending indicating desiccant. All RDT products with self- or partial-indicating silica gel (n = 22 and 8 respectively) contained the toxic cobalt dichloride as humidity indicator. Colour change indicating humidity saturation was observed for 8/16 RDT products, at a median incidence of 0.8% (range 0.05%-4.6%) of sachets inspected. In all RDTs with partial-indicating silica gel, sachets with no colour indicating beads were found (median proportion 13.5% (0.6% - 17.8%) per product) and additional light was needed to assess the humidity colour. Less than half (14/30, 47%) IFUs of RDT products with indicating desiccants mentioned to check the humidity saturation before using the test. Information on properties, safety hazards and disposal of the desiccant was not included in any of the IFUs. There were no differences between Global Fund-listed and CE marked RDT products compared to those which were not. Similar findings were noted for a panel of 11 HIV RDTs that was assessed with the same checklist as the malaria RDTs.</p> <p>Conclusion</p> <p>RDTs showed shortcomings in desiccant type and information supplied in the IFU.</p>
topic Desiccant
Silica gel
Rapid diagnostic test
RDT-malaria
HIV
Diagnosis
url http://www.malariajournal.com/content/11/1/326
work_keys_str_mv AT barbebarbara assessmentofdesiccantsandtheirinstructionsforuseinrapiddiagnostictests
AT gilletphilippe assessmentofdesiccantsandtheirinstructionsforuseinrapiddiagnostictests
AT beelaertgreet assessmentofdesiccantsandtheirinstructionsforuseinrapiddiagnostictests
AT fransenkatrien assessmentofdesiccantsandtheirinstructionsforuseinrapiddiagnostictests
AT jacobsjan assessmentofdesiccantsandtheirinstructionsforuseinrapiddiagnostictests
_version_ 1716752575799230464