Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive

An experimental study of the control of the operating modes of the plate feeder based on a frequency-controlled electric drive in the mining industry has been carried out. The graphs of measurements of the electrical parameters of the electric drive supplied from the frequency converter of the plast...

Full description

Bibliographic Details
Main Authors: Toirov Olimjon, Urokov Sardor, Mirkhonov Utkir, Afrisal Hadha, Jumaeva Dilnoza
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/64/e3sconf_suse2021_01086.pdf
id doaj-ab55f9d7bb6247bdbcac681272729a43
record_format Article
spelling doaj-ab55f9d7bb6247bdbcac681272729a432021-07-15T06:53:02ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012880108610.1051/e3sconf/202128801086e3sconf_suse2021_01086Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric driveToirov Olimjon0Urokov Sardor1Mirkhonov Utkir2Afrisal Hadha3Jumaeva Dilnoza4Tashkent State Technical University, DSc., Prof. Head of the Department of Electrical machineTashkent State Technical University, Doctoral Student, Department of Electrical machineBukhara Engineering Technological Institute, Senior Lecturer, Doctoral Student, Department of Energy AuditUniversitas Diponegoro, Department of Electrical EngineeringInstitute of General and Inorganic Chemistry of the Academy of Sciences of the Republic of UzbekistanAn experimental study of the control of the operating modes of the plate feeder based on a frequency-controlled electric drive in the mining industry has been carried out. The graphs of measurements of the electrical parameters of the electric drive supplied from the frequency converter of the plastic feeder, instantaneous values of harmonic composition of voltage and current up to 50 harmonics, as well as changes in current and voltage harmonics over a period of 30 minutes were obtained. Measurement of oscillograms of voltage and current of each phase in operating mode and the moment of turning off and turning on the electric motor of the plastic feeder. The issues of control of starting modes of the plate feeder from frequency-controlled electric drives are considered. It has been determined that frequency start-up with the linear control law for the frequency of the plate feeder as a function of time and technological parameters are the most acceptable condition for starting modes.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/64/e3sconf_suse2021_01086.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Toirov Olimjon
Urokov Sardor
Mirkhonov Utkir
Afrisal Hadha
Jumaeva Dilnoza
spellingShingle Toirov Olimjon
Urokov Sardor
Mirkhonov Utkir
Afrisal Hadha
Jumaeva Dilnoza
Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
E3S Web of Conferences
author_facet Toirov Olimjon
Urokov Sardor
Mirkhonov Utkir
Afrisal Hadha
Jumaeva Dilnoza
author_sort Toirov Olimjon
title Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
title_short Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
title_full Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
title_fullStr Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
title_full_unstemmed Experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
title_sort experimental study of the control of operating modes of a plate feeder based on the frequency-controlled electric drive
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description An experimental study of the control of the operating modes of the plate feeder based on a frequency-controlled electric drive in the mining industry has been carried out. The graphs of measurements of the electrical parameters of the electric drive supplied from the frequency converter of the plastic feeder, instantaneous values of harmonic composition of voltage and current up to 50 harmonics, as well as changes in current and voltage harmonics over a period of 30 minutes were obtained. Measurement of oscillograms of voltage and current of each phase in operating mode and the moment of turning off and turning on the electric motor of the plastic feeder. The issues of control of starting modes of the plate feeder from frequency-controlled electric drives are considered. It has been determined that frequency start-up with the linear control law for the frequency of the plate feeder as a function of time and technological parameters are the most acceptable condition for starting modes.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/64/e3sconf_suse2021_01086.pdf
work_keys_str_mv AT toirovolimjon experimentalstudyofthecontrolofoperatingmodesofaplatefeederbasedonthefrequencycontrolledelectricdrive
AT urokovsardor experimentalstudyofthecontrolofoperatingmodesofaplatefeederbasedonthefrequencycontrolledelectricdrive
AT mirkhonovutkir experimentalstudyofthecontrolofoperatingmodesofaplatefeederbasedonthefrequencycontrolledelectricdrive
AT afrisalhadha experimentalstudyofthecontrolofoperatingmodesofaplatefeederbasedonthefrequencycontrolledelectricdrive
AT jumaevadilnoza experimentalstudyofthecontrolofoperatingmodesofaplatefeederbasedonthefrequencycontrolledelectricdrive
_version_ 1721301800295858176