We have retrospectively investigated the relationship between the presence of total aerobic bacteria (TAB) and the presence of <em>Legionella</em> sp. in 576 water samples from industrial cooling towers. A lower percentage of positive samples for <em>Legionella</em> sp. (19.8...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedad Española de Sanidad Ambiental
2006-12-01
|
Series: | Revista de Salud Ambiental |
Subjects: | |
Online Access: | https://ojs.diffundit.com/index.php/rsa/article/view/302 |
id |
doaj-ab44cb5f2a9142da8fd136fd6f7c4dd7 |
---|---|
record_format |
Article |
spelling |
doaj-ab44cb5f2a9142da8fd136fd6f7c4dd72021-06-15T06:08:53ZengSociedad Española de Sanidad AmbientalRevista de Salud Ambiental1577-95721697-27912006-12-0161-28991260Microbiological and sampling criteria established in the present Spanish legislation for the control of LegionellaIsabel Inza RojasWe have retrospectively investigated the relationship between the presence of total aerobic bacteria (TAB) and the presence of <em>Legionella</em> sp. in 576 water samples from industrial cooling towers. A lower percentage of positive samples for <em>Legionella</em> sp. (19.8%) was encountered when the concentration of TAB was above 104 CFU/ml than below this concentration (80.2%). The concentration of 104 CFU/ml TAB is established in Spanish legislation as the action limit, above which a higher risk of <em>Legionella</em> positive samples is expected. Despite that, our results indicate that levels of TAB above 100 or 1000 CFU/ml seem more useful for predicting the presence of <em>Legionella</em> in the cooling towers investigated. We observed that the concentration of TAB was significatively higher in the positive samples for <em>Legionella</em> than in the negative ones, which seems to indicate that TAB is a good tool for evaluating the effectiveness of the Autocontrol Safety Measures of those cooling towers. Our results reinforce the need for controlling the levels of TAB (at 36 ± 1 oC) because it is a good indicator of the presence of <em>Legionella</em> spp. despite the fact that the standard established as the action limit should be lowered. Within the study we also reviewed the sampling procedures and provide new data on the incubation period of the disease and on the genotyping methods classically employed in epidemiological investigation.https://ojs.diffundit.com/index.php/rsa/article/view/302bacterias aerobias totaleslegionellaappccaflppfgemlst |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Isabel Inza Rojas |
spellingShingle |
Isabel Inza Rojas Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella Revista de Salud Ambiental bacterias aerobias totales legionella appcc aflp pfge mlst |
author_facet |
Isabel Inza Rojas |
author_sort |
Isabel Inza Rojas |
title |
Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella |
title_short |
Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella |
title_full |
Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella |
title_fullStr |
Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella |
title_full_unstemmed |
Microbiological and sampling criteria established in the present Spanish legislation for the control of Legionella |
title_sort |
microbiological and sampling criteria established in the present spanish legislation for the control of legionella |
publisher |
Sociedad Española de Sanidad Ambiental |
series |
Revista de Salud Ambiental |
issn |
1577-9572 1697-2791 |
publishDate |
2006-12-01 |
description |
We have retrospectively investigated the relationship between the presence of total aerobic bacteria (TAB) and the presence of <em>Legionella</em> sp. in 576 water samples from industrial cooling towers. A lower percentage of positive samples for <em>Legionella</em> sp. (19.8%) was encountered when the concentration of TAB was above 104 CFU/ml than below this concentration (80.2%). The concentration of 104 CFU/ml TAB is established in Spanish legislation as the action limit, above which a higher risk of <em>Legionella</em> positive samples is expected. Despite that, our results indicate that levels of TAB above 100 or 1000 CFU/ml seem more useful for predicting the presence of <em>Legionella</em> in the cooling towers investigated. We observed that the concentration of TAB was significatively higher in the positive samples for <em>Legionella</em> than in the negative ones, which seems to indicate that TAB is a good tool for evaluating the effectiveness of the Autocontrol Safety Measures of those cooling towers. Our results reinforce the need for controlling the levels of TAB (at 36 ± 1 oC) because it is a good indicator of the presence of <em>Legionella</em> spp. despite the fact that the standard established as the action limit should be lowered. Within the study we also reviewed the sampling procedures and provide new data on the incubation period of the disease and on the genotyping methods classically employed in epidemiological investigation. |
topic |
bacterias aerobias totales legionella appcc aflp pfge mlst |
url |
https://ojs.diffundit.com/index.php/rsa/article/view/302 |
work_keys_str_mv |
AT isabelinzarojas microbiologicalandsamplingcriteriaestablishedinthepresentspanishlegislationforthecontroloflegionella |
_version_ |
1721377105007083520 |