Improving the performance of 241Am-Be for PGNAA applications using a proper shielding for neutron source and the NaI detector
The gamma ray spectrum resolution from a 241Am-Be source-based prompt gamma ray activation analysis set-up has been observed to increase in the energy region of interest with enclosing the NaI detector in a proper neutron and gamma ray shield. We have investigated the tact that the peak resolutio...
Main Authors: | Panjeh Hamed, Hakimabad Hashem M., Motavalli Lalle R. |
---|---|
Format: | Article |
Language: | English |
Published: |
VINCA Institute of Nuclear Sciences
2010-01-01
|
Series: | Nuclear Technology and Radiation Protection |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/1451-3994/2010/1451-39941003205P.pdf |
Similar Items
-
Study on detection geometry and detector shielding for portable PGNAA system using PHITS
by: Abd Rashid, I.Q, et al.
Published: (2018) -
Design and construction of a shield for the 9" x 9" NaI(Tl) well-type detector
by: Hansman Jan
Published: (2014-01-01) -
Design of the Coal PGNAA Device by MOCA Program
by: YANG Lifang1;GAO Xiang2
Published: (2018-02-01) -
Neutron shielding properties of a borated high-density glass
by: Saeed Aly Abdallah, et al.
Published: (2017-01-01) -
Investigation of thermal neutron detection capability of a CdZnTe detector in a mixed gamma-neutron radiation field
by: Yücel Haluk, et al.
Published: (2018-09-01)