Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies
Background: Electron therapy has advantages of dose uniformity in target volume and dose reduction in deeper tissues for breast cancer therapy. The aim of this study was to determine observed dose in target volume and normal tissues such as lung in breast cancer therapy after mastectomy. Methods: T...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Vesnu Publications
2017-08-01
|
Series: | مجله دانشکده پزشکی اصفهان |
Subjects: | |
Online Access: | http://jims.mui.ac.ir/index.php/jims/article/view/8167 |
id |
doaj-aac3377887af403eb784cf79c6f94e2d |
---|---|
record_format |
Article |
spelling |
doaj-aac3377887af403eb784cf79c6f94e2d2020-11-25T01:49:48ZfasVesnu Publications مجله دانشکده پزشکی اصفهان1027-75951735-854X2017-08-01354377968002582Chest Dose Assessment in Breast Cancer Therapy Using Two Electron EnergiesDaryoush Shahbazi-Gahrouei0Abbas Gookizadeh1Mahboubeh Sohrabi2Zahra Arab-Bafrani3Professor, Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranAssociate Professor, Department of Radiation Oncology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranDepartment of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, IranDepartment of Medical Physics-Clinical Biochemistry, School of Medicine, Golestan University of Medical Sciences, Gorgan, IranBackground: Electron therapy has advantages of dose uniformity in target volume and dose reduction in deeper tissues for breast cancer therapy. The aim of this study was to determine observed dose in target volume and normal tissues such as lung in breast cancer therapy after mastectomy. Methods: The phantom was designed based on the chest wall computed tomography (CT) images after mastectomy and treatment planning software. Two linear accelerator (Neptune 10 and Saturn 20) machines were used to deliver electron beams at a dose of 200 cGy (10 and 13 MeV). Dose measurements were done using thermoluminescence dosimeter lithium fluoride chips (TLD-100: LiF: Mg; Tl). Findings: The percentage of measured dose in internal mammary nodes, axillary nodes, and chest wall using 13 MeV was found to be 97.5, 96, and 98, respectively. In treatment with 10 MeV electron, this values changed to 99.7, 90.5, and 77 percent, respectively. The anterior lung percentage dose was 78 with 13 MeV electrons while the posterior part of lung received 47 percent with 10 MeV electron beam. Dose values for anterior and posterior part of lung changed to 83 and 45 percent, respectively. Conclusion: Using 13 MeV, internal mammary and axillary lymph nodes as well as the chest wall received adequate doses but lung received excessive dose. Using 10 MeV, internal mammary nodes and chest wall were well exposed to radiation, but axillary lymph nodes did not receive enough dose. Therefore, this dose shortage should be compensated by additional posterior fields using radiation therapy with photon energies.http://jims.mui.ac.ir/index.php/jims/article/view/8167DosimetryBreast cancerElectron therapyThermoluminescence dosimeter (TLD) |
collection |
DOAJ |
language |
fas |
format |
Article |
sources |
DOAJ |
author |
Daryoush Shahbazi-Gahrouei Abbas Gookizadeh Mahboubeh Sohrabi Zahra Arab-Bafrani |
spellingShingle |
Daryoush Shahbazi-Gahrouei Abbas Gookizadeh Mahboubeh Sohrabi Zahra Arab-Bafrani Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies مجله دانشکده پزشکی اصفهان Dosimetry Breast cancer Electron therapy Thermoluminescence dosimeter (TLD) |
author_facet |
Daryoush Shahbazi-Gahrouei Abbas Gookizadeh Mahboubeh Sohrabi Zahra Arab-Bafrani |
author_sort |
Daryoush Shahbazi-Gahrouei |
title |
Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies |
title_short |
Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies |
title_full |
Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies |
title_fullStr |
Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies |
title_full_unstemmed |
Chest Dose Assessment in Breast Cancer Therapy Using Two Electron Energies |
title_sort |
chest dose assessment in breast cancer therapy using two electron energies |
publisher |
Vesnu Publications |
series |
مجله دانشکده پزشکی اصفهان |
issn |
1027-7595 1735-854X |
publishDate |
2017-08-01 |
description |
Background: Electron therapy has advantages of dose uniformity in target volume and dose reduction in deeper tissues for breast cancer therapy. The aim of this study was to determine observed dose in target volume and normal tissues such as lung in breast cancer therapy after mastectomy.
Methods: The phantom was designed based on the chest wall computed tomography (CT) images after mastectomy and treatment planning software. Two linear accelerator (Neptune 10 and Saturn 20) machines were used to deliver electron beams at a dose of 200 cGy (10 and 13 MeV). Dose measurements were done using thermoluminescence dosimeter lithium fluoride chips (TLD-100: LiF: Mg; Tl).
Findings: The percentage of measured dose in internal mammary nodes, axillary nodes, and chest wall using 13 MeV was found to be 97.5, 96, and 98, respectively. In treatment with 10 MeV electron, this values changed to 99.7, 90.5, and 77 percent, respectively. The anterior lung percentage dose was 78 with 13 MeV electrons while the posterior part of lung received 47 percent with 10 MeV electron beam. Dose values for anterior and posterior part of lung changed to 83 and 45 percent, respectively.
Conclusion: Using 13 MeV, internal mammary and axillary lymph nodes as well as the chest wall received adequate doses but lung received excessive dose. Using 10 MeV, internal mammary nodes and chest wall were well exposed to radiation, but axillary lymph nodes did not receive enough dose. Therefore, this dose shortage should be compensated by additional posterior fields using radiation therapy with photon energies. |
topic |
Dosimetry Breast cancer Electron therapy Thermoluminescence dosimeter (TLD) |
url |
http://jims.mui.ac.ir/index.php/jims/article/view/8167 |
work_keys_str_mv |
AT daryoushshahbazigahrouei chestdoseassessmentinbreastcancertherapyusingtwoelectronenergies AT abbasgookizadeh chestdoseassessmentinbreastcancertherapyusingtwoelectronenergies AT mahboubehsohrabi chestdoseassessmentinbreastcancertherapyusingtwoelectronenergies AT zahraarabbafrani chestdoseassessmentinbreastcancertherapyusingtwoelectronenergies |