DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006
In the article design of composite (timber and plywood) skin panel has been considered according European and national standards. The panel consists of timber webs and plywood skin. The design parameters are depth of webs and distance between webs within the defined skin parameters. In design the me...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Poltava National Technical Yuri Kondratyuk University
2019-10-01
|
Series: | Збірник наукових праць: Серія: Галузеве машинобудування, будівництво |
Subjects: | |
Online Access: | http://journals.nupp.edu.ua/znp/article/view/1887 |
id |
doaj-aa3145700e864aee856ea45a0de9fdcd |
---|---|
record_format |
Article |
spelling |
doaj-aa3145700e864aee856ea45a0de9fdcd2020-11-25T03:33:03ZengPoltava National Technical Yuri Kondratyuk University Збірник наукових праць: Серія: Галузеве машинобудування, будівництво2409-90742518-11062019-10-01253374110.26906/znp.2019.53.18871887DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006Sergiy Pichugin0Sergiy Shkirenko1Maryna Pents2Poltava National Technical Yuri Kondratyuk UniversityPoltava National Technical Yuri Kondratyuk UniversityPoltava National Technical Yuri Kondratyuk UniversityIn the article design of composite (timber and plywood) skin panel has been considered according European and national standards. The panel consists of timber webs and plywood skin. The design parameters are depth of webs and distance between webs within the defined skin parameters. In design the method of fictitious cross-section is applied. Check of the ultimate limit states is conducted in accordance with EN 1995-1-1 (ДБН В.2.6-161:2017). Loads to the panel are determined according to ДБН В.1.2.-2:2006. The usage of European and national standards complies with the actual requirements and widen methodological base.http://journals.nupp.edu.ua/znp/article/view/1887roof memberstwo-sided composite skin paneldesign of building constructionsloads on building constructions |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sergiy Pichugin Sergiy Shkirenko Maryna Pents |
spellingShingle |
Sergiy Pichugin Sergiy Shkirenko Maryna Pents DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006 Збірник наукових праць: Серія: Галузеве машинобудування, будівництво roof members two-sided composite skin panel design of building constructions loads on building constructions |
author_facet |
Sergiy Pichugin Sergiy Shkirenko Maryna Pents |
author_sort |
Sergiy Pichugin |
title |
DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006 |
title_short |
DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006 |
title_full |
DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006 |
title_fullStr |
DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006 |
title_full_unstemmed |
DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006 |
title_sort |
design of composite skin panel for roof in accordance with the requirements of en 1995-1-1 and gsn в.1.2-2:2006 |
publisher |
Poltava National Technical Yuri Kondratyuk University |
series |
Збірник наукових праць: Серія: Галузеве машинобудування, будівництво |
issn |
2409-9074 2518-1106 |
publishDate |
2019-10-01 |
description |
In the article design of composite (timber and plywood) skin panel has been considered according European and national
standards. The panel consists of timber webs and plywood skin. The design parameters are depth of webs and distance between webs within the defined skin parameters. In design the method of fictitious cross-section is applied. Check of the ultimate limit states is conducted in accordance with EN 1995-1-1 (ДБН В.2.6-161:2017). Loads to the panel are determined according to ДБН В.1.2.-2:2006. The usage of European and national standards complies with the actual requirements and
widen methodological base. |
topic |
roof members two-sided composite skin panel design of building constructions loads on building constructions |
url |
http://journals.nupp.edu.ua/znp/article/view/1887 |
work_keys_str_mv |
AT sergiypichugin designofcompositeskinpanelforroofinaccordancewiththerequirementsofen199511andgsnv1222006 AT sergiyshkirenko designofcompositeskinpanelforroofinaccordancewiththerequirementsofen199511andgsnv1222006 AT marynapents designofcompositeskinpanelforroofinaccordancewiththerequirementsofen199511andgsnv1222006 |
_version_ |
1724565044325253120 |