Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application
<b>Abstrac</b>t: To address the support problem of large-diameter drilling shafts in the west area of Zhangji coal mine, a thinner shaft lining structure composed of double layers of steel plate and high-performance concrete is proposed herein. Firstly, a series of tests of high-performa...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/10/8/2938 |
id |
doaj-a94298edc2db4280b231a87a09f04117 |
---|---|
record_format |
Article |
spelling |
doaj-a94298edc2db4280b231a87a09f041172020-11-25T01:44:06ZengMDPI AGApplied Sciences2076-34172020-04-01102938293810.3390/app10082938Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its ApplicationZhishu Yao0Ping Zhang1Hua Cheng2Weipei Xue3Xiang Li4School of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, ChinaSchool of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, ChinaSchool of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, ChinaSchool of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, ChinaSchool of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, China<b>Abstrac</b>t: To address the support problem of large-diameter drilling shafts in the west area of Zhangji coal mine, a thinner shaft lining structure composed of double layers of steel plate and high-performance concrete is proposed herein. Firstly, a series of tests of high-performance concrete preparation were carried out, and the optimized mix ratio of pumping concrete with 60–70 MPa strength for shaft lining of the drilled shaft was obtained. Then, shaft lining models were designed according to the similarity theory, and the mechanical properties of the shaft lining were experimentally studied by loading test. The test results showed that the stress state of concrete in the shaft was obviously improved, and the compressive strength of concrete was increased by 1.97–2.52 times. Finally, the results of the study were applied to a shaft in the control strata of the inlet shaft in the west area of Zhangji coal mine, which made it possible to use the drilling method to construct the shaft. The following field measurement showed that the annular strain of the shaft lining concrete was −487 με, which is far less than the ultimate strain value of C65 concrete, and the shaft lining structure was kept safe and reliable.https://www.mdpi.com/2076-3417/10/8/2938high-performance concretedual-steel-plate-confinedcomposite shaft lining structuretest studyengineering application |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zhishu Yao Ping Zhang Hua Cheng Weipei Xue Xiang Li |
spellingShingle |
Zhishu Yao Ping Zhang Hua Cheng Weipei Xue Xiang Li Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application Applied Sciences high-performance concrete dual-steel-plate-confined composite shaft lining structure test study engineering application |
author_facet |
Zhishu Yao Ping Zhang Hua Cheng Weipei Xue Xiang Li |
author_sort |
Zhishu Yao |
title |
Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application |
title_short |
Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application |
title_full |
Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application |
title_fullStr |
Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application |
title_full_unstemmed |
Testing of a Dual-Steel-Plate-Confined High-Performance Concrete Composite Shaft Lining Structure and Its Application |
title_sort |
testing of a dual-steel-plate-confined high-performance concrete composite shaft lining structure and its application |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2020-04-01 |
description |
<b>Abstrac</b>t: To address the support problem of large-diameter drilling shafts in the west area of Zhangji coal mine, a thinner shaft lining structure composed of double layers of steel plate and high-performance concrete is proposed herein. Firstly, a series of tests of high-performance concrete preparation were carried out, and the optimized mix ratio of pumping concrete with 60–70 MPa strength for shaft lining of the drilled shaft was obtained. Then, shaft lining models were designed according to the similarity theory, and the mechanical properties of the shaft lining were experimentally studied by loading test. The test results showed that the stress state of concrete in the shaft was obviously improved, and the compressive strength of concrete was increased by 1.97–2.52 times. Finally, the results of the study were applied to a shaft in the control strata of the inlet shaft in the west area of Zhangji coal mine, which made it possible to use the drilling method to construct the shaft. The following field measurement showed that the annular strain of the shaft lining concrete was −487 με, which is far less than the ultimate strain value of C65 concrete, and the shaft lining structure was kept safe and reliable. |
topic |
high-performance concrete dual-steel-plate-confined composite shaft lining structure test study engineering application |
url |
https://www.mdpi.com/2076-3417/10/8/2938 |
work_keys_str_mv |
AT zhishuyao testingofadualsteelplateconfinedhighperformanceconcretecompositeshaftliningstructureanditsapplication AT pingzhang testingofadualsteelplateconfinedhighperformanceconcretecompositeshaftliningstructureanditsapplication AT huacheng testingofadualsteelplateconfinedhighperformanceconcretecompositeshaftliningstructureanditsapplication AT weipeixue testingofadualsteelplateconfinedhighperformanceconcretecompositeshaftliningstructureanditsapplication AT xiangli testingofadualsteelplateconfinedhighperformanceconcretecompositeshaftliningstructureanditsapplication |
_version_ |
1725029869867237376 |