Numerical Signal Analysis of Thermo-Cyclically Operated MOG Gas Sensor Arrays for Early Identification of Emissions from Overloaded Electric Cables
A thermo-cyclically operated multi metal oxide gas sensor (MOG) array is introduced together with a novel signal analysis approach (SimSens) for identifying the emissions from overheated isolation cable materials thereby detecting the fires originated in electrical cabinets at early stages. The MOG...
Main Authors: | Rolf Seifert, Hubert B. Keller, Navas Illyaskutty, Jens Knoblauch, Heinz Kohler |
---|---|
Format: | Article |
Language: | English |
Published: |
IFSA Publishing, S.L.
2015-10-01
|
Series: | Sensors & Transducers |
Subjects: | |
Online Access: | http://www.sensorsportal.com/HTML/DIGEST/october_2015/Vol_193/P_2738.pdf |
Similar Items
-
Development of Gas Sensor Array based on Phthalocyanines Functionalized TiO<sub>2</sub>/ZnO Heterojunction Thin Films
by: Jareena Begam Jakir Hussain, et al.
Published: (2018-11-01) -
Odor Recognition of Thermal Decomposition Products of Electric Cables Using Odor Sensing Arrays
by: Yuanchang Liu, et al.
Published: (2021-09-01) -
Wireless Sensor Array Network DoA Estimation from Compressed Array Data via Joint Sparse Representation
by: Kai Yu, et al.
Published: (2016-05-01) -
Multiple Sources Localization With WSN, Eliminating the Direction-of-Arrival Ambiguity Symmetric With Respect to the Planar Array
by: Yue Ivan Wu
Published: (2018-01-01) -
A Conductometric Indium Oxide Semiconducting Nanoparticle Enzymatic Biosensor Array
by: Tianhong Cui, et al.
Published: (2011-09-01)