Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking
A large volume sample stacking (LVSS) method in micellar electrokinetic chromatography (MEKC) with diode array detector was developed for the simultaneous separation and analysis of five compounds: protocatechuic acid, protocatechuic aldehyde, caffeic acid, syringetin and vanillin in <i>Ciboti...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-09-01
|
Series: | Separations |
Subjects: | |
Online Access: | https://www.mdpi.com/2297-8739/8/9/147 |
id |
doaj-a8c4758f78dd463481abd5393b042fc5 |
---|---|
record_format |
Article |
spelling |
doaj-a8c4758f78dd463481abd5393b042fc52021-09-26T01:24:45ZengMDPI AGSeparations2297-87392021-09-01814714710.3390/separations8090147Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample StackingLili Wang0Huifeng Xu1Lishuang Yu2Zaishi Zhu3Hongzhi Ye4Linglong Liu5Xihai Li6Jun Peng7Academy of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaAcademy of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaCollege of Pharmacy, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaAcademy of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaAcademy of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaCollege of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaFujian Key Laboratory of Integrative Medicine on Geriatrics, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaAcademy of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, ChinaA large volume sample stacking (LVSS) method in micellar electrokinetic chromatography (MEKC) with diode array detector was developed for the simultaneous separation and analysis of five compounds: protocatechuic acid, protocatechuic aldehyde, caffeic acid, syringetin and vanillin in <i>Cibotium barometz</i>. The electrophoretic separation was performed in a 10 mM sodium dodecyl sulfate (SDS) and 50 mM sodium borax-sodium dihydrogen phosphate system (pH = 8.5) with 10% methanol at a separation voltage of 30 kV after optimizing the typical parameters. The detection limits were from 32 pg to 65 pg, which were around 12–27 times lower than MEKC, and 500 times less than reported methods. Finally, the established method was validated to be applicable for the determination of protocatechuic acid and caffeic acid in <i>Cibotium barometz</i>. This proposed method is expected to facilitate the quality control of <i>Cibotium barometz</i>.https://www.mdpi.com/2297-8739/8/9/147capillary electrophoresis<i>Cibotium barometz</i>large volume sample stackingmicellar electrokinetic chromatography |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Lili Wang Huifeng Xu Lishuang Yu Zaishi Zhu Hongzhi Ye Linglong Liu Xihai Li Jun Peng |
spellingShingle |
Lili Wang Huifeng Xu Lishuang Yu Zaishi Zhu Hongzhi Ye Linglong Liu Xihai Li Jun Peng Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking Separations capillary electrophoresis <i>Cibotium barometz</i> large volume sample stacking micellar electrokinetic chromatography |
author_facet |
Lili Wang Huifeng Xu Lishuang Yu Zaishi Zhu Hongzhi Ye Linglong Liu Xihai Li Jun Peng |
author_sort |
Lili Wang |
title |
Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking |
title_short |
Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking |
title_full |
Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking |
title_fullStr |
Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking |
title_full_unstemmed |
Simultaneous Separation and Analysis of Five Compounds in <i>Cibotium barometz</i> by Micellar Electrokinetic Chromatography with Large-Volume Sample Stacking |
title_sort |
simultaneous separation and analysis of five compounds in <i>cibotium barometz</i> by micellar electrokinetic chromatography with large-volume sample stacking |
publisher |
MDPI AG |
series |
Separations |
issn |
2297-8739 |
publishDate |
2021-09-01 |
description |
A large volume sample stacking (LVSS) method in micellar electrokinetic chromatography (MEKC) with diode array detector was developed for the simultaneous separation and analysis of five compounds: protocatechuic acid, protocatechuic aldehyde, caffeic acid, syringetin and vanillin in <i>Cibotium barometz</i>. The electrophoretic separation was performed in a 10 mM sodium dodecyl sulfate (SDS) and 50 mM sodium borax-sodium dihydrogen phosphate system (pH = 8.5) with 10% methanol at a separation voltage of 30 kV after optimizing the typical parameters. The detection limits were from 32 pg to 65 pg, which were around 12–27 times lower than MEKC, and 500 times less than reported methods. Finally, the established method was validated to be applicable for the determination of protocatechuic acid and caffeic acid in <i>Cibotium barometz</i>. This proposed method is expected to facilitate the quality control of <i>Cibotium barometz</i>. |
topic |
capillary electrophoresis <i>Cibotium barometz</i> large volume sample stacking micellar electrokinetic chromatography |
url |
https://www.mdpi.com/2297-8739/8/9/147 |
work_keys_str_mv |
AT liliwang simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT huifengxu simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT lishuangyu simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT zaishizhu simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT hongzhiye simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT linglongliu simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT xihaili simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking AT junpeng simultaneousseparationandanalysisoffivecompoundsinicibotiumbarometzibymicellarelectrokineticchromatographywithlargevolumesamplestacking |
_version_ |
1716869014057123840 |