Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study

BackgroundElectrocardiogram (ECG) monitoring in daily life is essential for effective management of cardiovascular disease, a leading cause of death. Wearable ECG measurement systems in the form of clothing have been proposed to replace Holter monitors used for clinical ECG m...

Full description

Bibliographic Details
Main Authors: Gwon, Danbi, Cho, Hakyung, Shin, Hangsik
Format: Article
Language:English
Published: JMIR Publications 2021-05-01
Series:JMIR mHealth and uHealth
Online Access:https://mhealth.jmir.org/2021/5/e26469
id doaj-a7a05201bb5e48de839977e4e90c51fa
record_format Article
spelling doaj-a7a05201bb5e48de839977e4e90c51fa2021-05-11T14:31:06ZengJMIR PublicationsJMIR mHealth and uHealth2291-52222021-05-0195e2646910.2196/26469Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability StudyGwon, DanbiCho, HakyungShin, Hangsik BackgroundElectrocardiogram (ECG) monitoring in daily life is essential for effective management of cardiovascular disease, a leading cause of death. Wearable ECG measurement systems in the form of clothing have been proposed to replace Holter monitors used for clinical ECG monitoring; however, they have limitations in daily use because they compress the upper body and, in doing so, cause discomfort during wear. ObjectiveThe purpose of this study was to develop a wireless wearable ECG monitoring system that includes a textile ECG electrode that can be applied to the lining of pants and can be used in the same way that existing lower clothing is worn, without compression to the upper body. MethodsA textile electrode with stretchable characteristics was fabricated by knitting a conductive yarn together with polyester-polyurethane fiber, which was then coated with silver compound; an ECG electrode was developed by placing it on an elastic band in a modified limb lead configuration. In addition, a system with analog-to-digital conversion, wireless communication, and a smartphone app was developed, allowing users to be able to check and store their own ECGs in real time. A signal processing algorithm was also developed to remove noise from the obtained signal and to calculate the heart rate. To evaluate the ECG and heart rate measurement performance of the developed module, a comparative evaluation with a commercial device was performed. ECGs were measured for 5 minutes each in standing, sitting, and lying positions; the mean absolute percentage errors of heart rates measured with both systems were then compared. ResultsThe system was developed in the form of a belt buckle with a size of 53 × 45 × 12 mm (width × height × depth) and a weight of 23 g. In a qualitative evaluation, it was confirmed that the P-QRS-T waveform was clearly observed in ECGs obtained with the wearable system. From the results of the heart rate estimation, the developed system could track changes in heart rate as calculated by a commercial ECG measuring device; in addition, the mean absolute percentage errors of heart rates were 1.80%, 2.84%, and 2.48% in the standing, sitting, and lying positions, respectively. ConclusionsThe developed system was able to effectively measure ECG and calculate heart rate simply through being worn as existing clothing without upper body pressure. It is anticipated that general usability can be secured through further evaluation under more diverse conditions.https://mhealth.jmir.org/2021/5/e26469
collection DOAJ
language English
format Article
sources DOAJ
author Gwon, Danbi
Cho, Hakyung
Shin, Hangsik
spellingShingle Gwon, Danbi
Cho, Hakyung
Shin, Hangsik
Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study
JMIR mHealth and uHealth
author_facet Gwon, Danbi
Cho, Hakyung
Shin, Hangsik
author_sort Gwon, Danbi
title Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study
title_short Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study
title_full Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study
title_fullStr Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study
title_full_unstemmed Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study
title_sort feasibility of a waistband-type wireless wearable electrocardiogram monitoring system based on a textile electrode: development and usability study
publisher JMIR Publications
series JMIR mHealth and uHealth
issn 2291-5222
publishDate 2021-05-01
description BackgroundElectrocardiogram (ECG) monitoring in daily life is essential for effective management of cardiovascular disease, a leading cause of death. Wearable ECG measurement systems in the form of clothing have been proposed to replace Holter monitors used for clinical ECG monitoring; however, they have limitations in daily use because they compress the upper body and, in doing so, cause discomfort during wear. ObjectiveThe purpose of this study was to develop a wireless wearable ECG monitoring system that includes a textile ECG electrode that can be applied to the lining of pants and can be used in the same way that existing lower clothing is worn, without compression to the upper body. MethodsA textile electrode with stretchable characteristics was fabricated by knitting a conductive yarn together with polyester-polyurethane fiber, which was then coated with silver compound; an ECG electrode was developed by placing it on an elastic band in a modified limb lead configuration. In addition, a system with analog-to-digital conversion, wireless communication, and a smartphone app was developed, allowing users to be able to check and store their own ECGs in real time. A signal processing algorithm was also developed to remove noise from the obtained signal and to calculate the heart rate. To evaluate the ECG and heart rate measurement performance of the developed module, a comparative evaluation with a commercial device was performed. ECGs were measured for 5 minutes each in standing, sitting, and lying positions; the mean absolute percentage errors of heart rates measured with both systems were then compared. ResultsThe system was developed in the form of a belt buckle with a size of 53 × 45 × 12 mm (width × height × depth) and a weight of 23 g. In a qualitative evaluation, it was confirmed that the P-QRS-T waveform was clearly observed in ECGs obtained with the wearable system. From the results of the heart rate estimation, the developed system could track changes in heart rate as calculated by a commercial ECG measuring device; in addition, the mean absolute percentage errors of heart rates were 1.80%, 2.84%, and 2.48% in the standing, sitting, and lying positions, respectively. ConclusionsThe developed system was able to effectively measure ECG and calculate heart rate simply through being worn as existing clothing without upper body pressure. It is anticipated that general usability can be secured through further evaluation under more diverse conditions.
url https://mhealth.jmir.org/2021/5/e26469
work_keys_str_mv AT gwondanbi feasibilityofawaistbandtypewirelesswearableelectrocardiogrammonitoringsystembasedonatextileelectrodedevelopmentandusabilitystudy
AT chohakyung feasibilityofawaistbandtypewirelesswearableelectrocardiogrammonitoringsystembasedonatextileelectrodedevelopmentandusabilitystudy
AT shinhangsik feasibilityofawaistbandtypewirelesswearableelectrocardiogrammonitoringsystembasedonatextileelectrodedevelopmentandusabilitystudy
_version_ 1721444147316916224